{"api_version":"1","generated_at":"2026-04-23T00:40:06+00:00","cve":"CVE-2021-3712","urls":{"html":"https://cve.report/CVE-2021-3712","api":"https://cve.report/api/cve/CVE-2021-3712.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-3712","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-3712"},"summary":{"title":"Read buffer overruns processing ASN.1 strings","description":"ASN.1 strings are represented internally within OpenSSL as an ASN1_STRING structure which contains a buffer holding the string data and a field holding the buffer length. This contrasts with normal C strings which are repesented as a buffer for the string data which is terminated with a NUL (0) byte. Although not a strict requirement, ASN.1 strings that are parsed using OpenSSL's own \"d2i\" functions (and other similar parsing functions) as well as any string whose value has been set with the ASN1_STRING_set() function will additionally NUL terminate the byte array in the ASN1_STRING structure. However, it is possible for applications to directly construct valid ASN1_STRING structures which do not NUL terminate the byte array by directly setting the \"data\" and \"length\" fields in the ASN1_STRING array. This can also happen by using the ASN1_STRING_set0() function. Numerous OpenSSL functions that print ASN.1 data have been found to assume that the ASN1_STRING byte array will be NUL terminated, even though this is not guaranteed for strings that have been directly constructed. Where an application requests an ASN.1 structure to be printed, and where that ASN.1 structure contains ASN1_STRINGs that have been directly constructed by the application without NUL terminating the \"data\" field, then a read buffer overrun can occur. The same thing can also occur during name constraints processing of certificates (for example if a certificate has been directly constructed by the application instead of loading it via the OpenSSL parsing functions, and the certificate contains non NUL terminated ASN1_STRING structures). It can also occur in the X509_get1_email(), X509_REQ_get1_email() and X509_get1_ocsp() functions. If a malicious actor can cause an application to directly construct an ASN1_STRING and then process it through one of the affected OpenSSL functions then this issue could be hit. This might result in a crash (causing a Denial of Service attack). It could also result in the disclosure of private memory contents (such as private keys, or sensitive plaintext). Fixed in OpenSSL 1.1.1l (Affected 1.1.1-1.1.1k). Fixed in OpenSSL 1.0.2za (Affected 1.0.2-1.0.2y).","state":"PUBLISHED","assigner":"openssl","published_at":"2021-08-24 15:15:09","updated_at":"2026-04-16 15:16:45"},"problem_types":["CWE-125","Buffer overflow","CWE-125 CWE-125 Out-of-bounds Read"],"metrics":[{"version":"3.1","source":"nvd@nist.gov","type":"Primary","score":"7.4","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H","baseScore":7.4,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"HIGH"}},{"version":"3.1","source":"ADP","type":"DECLARED","score":"7.4","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H","data":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.4,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H","version":"3.1"}},{"version":"3.1","source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","score":"7.4","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H","baseScore":7.4,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"HIGH"}},{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"5.8","severity":"","vector":"AV:N/AC:M/Au:N/C:P/I:N/A:P","data":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:N/A:P","baseScore":5.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"PARTIAL"}}],"references":[{"url":"https://www.oracle.com/security-alerts/cpuapr2022.html","name":"https://www.oracle.com/security-alerts/cpuapr2022.html","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Third Party Advisory"],"title":"Oracle Critical Patch Update Advisory - April 2022","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://security.netapp.com/advisory/ntap-20210827-0010/","name":"https://security.netapp.com/advisory/ntap-20210827-0010/","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"August 2021 OpenSSL Vulnerabilities in NetApp Products | NetApp Product Security","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-028723.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-028723.html","refsource":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.oracle.com/security-alerts/cpuoct2021.html","name":"https://www.oracle.com/security-alerts/cpuoct2021.html","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Third Party Advisory"],"title":"Oracle Critical Patch Update Advisory - October 2021","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://kc.mcafee.com/corporate/index?page=content&id=SB10366","name":"https://kc.mcafee.com/corporate/index?page=content&id=SB10366","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"Security Bulletin - ePolicy Orchestrator update addresses two product vulnerabilities (CVE-2021-31834 and CVE-2021-31835) and updates Java, OpenSSL, and Tomcat","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-389290.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-389290.html","refsource":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-244969.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-244969.html","refsource":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=ccb0a11145ee72b042d10593a64eaf9e8a55ec12","name":"https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=ccb0a11145ee72b042d10593a64eaf9e8a55ec12","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"git.openssl.org Git","mime":"text/xml","httpstatus":"404","archivestatus":"404"},{"url":"https://www.tenable.com/security/tns-2022-02","name":"https://www.tenable.com/security/tns-2022-02","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Third Party Advisory"],"title":"[R1] Nessus Network Monitor 6.0.0 Fixes Multiple Third-party Vulnerabilities - Security Advisory | Tenable®","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-244969.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-244969.pdf","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Third Party Advisory"],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://www.openssl.org/news/secadv/20210824.txt","name":"https://www.openssl.org/news/secadv/20210824.txt","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"title":"","mime":"text/plain","httpstatus":"200","archivestatus":"404"},{"url":"https://www.tenable.com/security/tns-2021-16","name":"https://www.tenable.com/security/tns-2021-16","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"[R1] Stand-alone Security Patch Available for Tenable.sc versions 5.16.0 to 5.19.1 - Security Advisory | Tenable®","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://security.gentoo.org/glsa/202210-02","name":"https://security.gentoo.org/glsa/202210-02","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"OpenSSL: Multiple Vulnerabilities (GLSA 202210-02) — Gentoo security","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.oracle.com/security-alerts/cpujan2022.html","name":"https://www.oracle.com/security-alerts/cpujan2022.html","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"Oracle Critical Patch Update Advisory - January 2022","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://security.netapp.com/advisory/ntap-20240621-0006/","name":"https://security.netapp.com/advisory/ntap-20240621-0006/","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://lists.apache.org/thread.html/rad5d9f83f0d11fb3f8bb148d179b8a9ad7c6a17f18d70e5805a713d1%40%3Cdev.tomcat.apache.org%3E","name":"https://lists.apache.org/thread.html/rad5d9f83f0d11fb3f8bb148d179b8a9ad7c6a17f18d70e5805a713d1%40%3Cdev.tomcat.apache.org%3E","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-019200.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-019200.html","refsource":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://lists.debian.org/debian-lts-announce/2021/09/msg00014.html","name":"https://lists.debian.org/debian-lts-announce/2021/09/msg00014.html","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mailing List","Third Party Advisory"],"title":"[SECURITY] [DLA 2766-1] openssl security update","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://lists.debian.org/debian-lts-announce/2021/09/msg00021.html","name":"https://lists.debian.org/debian-lts-announce/2021/09/msg00021.html","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mailing List","Third Party Advisory"],"title":"[SECURITY] [DLA 2774-1] openssl1.0 security update","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"http://www.openwall.com/lists/oss-security/2021/08/26/2","name":"http://www.openwall.com/lists/oss-security/2021/08/26/2","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mailing List","Third Party Advisory"],"title":"oss-security - OpenSSL SM2 Decryption Buffer Overflow (CVE-2021-3711), Read buffer\n overruns processing ASN.1 strings (CVE-2021-3712)","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=94d23fcff9b2a7a8368dfe52214d5c2569882c11","name":"https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=94d23fcff9b2a7a8368dfe52214d5c2569882c11","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"git.openssl.org Git - openssl.git/commitdiff","mime":"text/xml","httpstatus":"404","archivestatus":"200"},{"url":"https://lists.apache.org/thread.html/r18995de860f0e63635f3008fd2a6aca82394249476d21691e7c59c9e%40%3Cdev.tomcat.apache.org%3E","name":"https://lists.apache.org/thread.html/r18995de860f0e63635f3008fd2a6aca82394249476d21691e7c59c9e%40%3Cdev.tomcat.apache.org%3E","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://security.gentoo.org/glsa/202209-02","name":"https://security.gentoo.org/glsa/202209-02","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"IBM Spectrum Protect: Multiple Vulnerabilities (GLSA 202209-02) — Gentoo security","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Third Party Advisory"],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"200"},{"url":"https://www.debian.org/security/2021/dsa-4963","name":"https://www.debian.org/security/2021/dsa-4963","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"Debian -- Security Information -- DSA-4963-1 openssl","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=94d23fcff9b2a7a8368dfe52214d5c2569882c11","name":"CONFIRM:https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=94d23fcff9b2a7a8368dfe52214d5c2569882c11","refsource":"MITRE","tags":[],"title":"git.openssl.org Git - openssl.git/commitdiff","mime":"text/xml","httpstatus":"200","archivestatus":"404"},{"url":"https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=ccb0a11145ee72b042d10593a64eaf9e8a55ec12","name":"CONFIRM:https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=ccb0a11145ee72b042d10593a64eaf9e8a55ec12","refsource":"MITRE","tags":[],"title":"git.openssl.org Git - openssl.git/commitdiff","mime":"text/xml","httpstatus":"200","archivestatus":"404"},{"url":"https://lists.apache.org/thread.html/r18995de860f0e63635f3008fd2a6aca82394249476d21691e7c59c9e@%3Cdev.tomcat.apache.org%3E","name":"MLIST:[tomcat-dev] 20210825 OpenSSL security announcement - do we need a Tomcat Native release?","refsource":"MITRE","tags":[],"title":"Pony Mail!","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://lists.apache.org/thread.html/rad5d9f83f0d11fb3f8bb148d179b8a9ad7c6a17f18d70e5805a713d1@%3Cdev.tomcat.apache.org%3E","name":"MLIST:[tomcat-dev] 20210826 Re: OpenSSL security announcement - do we need a Tomcat Native release?","refsource":"MITRE","tags":[],"title":"Pony Mail!","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-3712","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-3712","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"OpenSSL","product":"OpenSSL","version":"affected Fixed in OpenSSL 1.1.1l (Affected 1.1.1-1.1.1k)","platforms":[]},{"source":"CNA","vendor":"OpenSSL","product":"OpenSSL","version":"affected Fixed in OpenSSL 1.0.2za (Affected 1.0.2-1.0.2y)","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"BFCClient","version":"affected V2.17 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"Industrial Edge - Machine Insight App","version":"affected * custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"Industrial Edge - PROFINET IO Connector","version":"affected All versions < V1.1.1","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"RUGGEDCOM RM1224 LTE(4G) EU","version":"affected All versions < V7.1","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"RUGGEDCOM RM1224 LTE(4G) NAM","version":"affected All versions < V7.1","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"RUGGEDCOM ROX MX5000","version":"affected V2.15.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"RUGGEDCOM ROX MX5000RE","version":"affected V2.15.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"RUGGEDCOM ROX RX1400","version":"affected V2.15.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"RUGGEDCOM ROX RX1500","version":"affected V2.15.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"RUGGEDCOM ROX RX1501","version":"affected V2.15.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"RUGGEDCOM ROX RX1510","version":"affected V2.15.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"RUGGEDCOM ROX RX1511","version":"affected V2.15.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"RUGGEDCOM ROX RX1512","version":"affected V2.15.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"RUGGEDCOM ROX RX1524","version":"affected V2.15.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"RUGGEDCOM ROX RX1536","version":"affected V2.15.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"RUGGEDCOM ROX RX5000","version":"affected V2.15.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE M804PB","version":"affected All versions < V7.1","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE M812-1 ADSL-Router","version":"affected All versions < V7.1","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE M812-1 ADSL-Router","version":"affected All versions < V7.1","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE M816-1 ADSL-Router","version":"affected All versions < V7.1","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE M816-1 ADSL-Router","version":"affected All versions < V7.1","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE M826-2 SHDSL-Router","version":"affected All versions < V7.1","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE M874-2","version":"affected All versions < V7.1","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE M874-3","version":"affected All versions < V7.1","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE M876-3","version":"affected All versions < V7.1","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE M876-3 (ROK)","version":"affected All versions < V7.1","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE M876-4 (EU)","version":"affected All versions < V7.1","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE M876-4 (NAM)","version":"affected All versions < V7.1","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE MUM853-1 (EU)","version":"affected V7.1 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE MUM856-1 (EU)","version":"affected V7.1 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE MUM856-1 (RoW)","version":"affected V7.1 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE S615 LAN-Router","version":"affected All versions < V7.1","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE SC622-2C","version":"affected All versions < V2.3","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE SC632-2C","version":"affected All versions < V2.3","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE SC636-2C","version":"affected All versions < V2.3","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE SC642-2C","version":"affected All versions < V2.3","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE SC646-2C","version":"affected All versions < V2.3","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W1748-1 M12","version":"affected V3.0.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W1748-1 M12","version":"affected V3.0.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W1788-1 M12","version":"affected V3.0.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W1788-2 EEC M12","version":"affected V3.0.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W1788-2 M12","version":"affected V3.0.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W1788-2IA M12","version":"affected V3.0.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W721-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W721-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W721-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W721-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45 (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45 (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W738-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W738-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W738-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W738-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W761-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W761-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W761-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W761-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45 (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45 (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12 EEC (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12 EEC (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 SFP","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 SFP","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 SFP","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 SFP","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2IA RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2IA RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2IA RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2IA RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE WAM766-1","version":"affected V1.2.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE WAM766-1 (US)","version":"affected V1.2.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE WAM766-1 EEC","version":"affected V1.2.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE WAM766-1 EEC (US)","version":"affected V1.2.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE WUM766-1","version":"affected V1.2.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE WUM766-1 (USA)","version":"affected V1.2.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X200-4P IRT","version":"affected V5.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X201-3P IRT","version":"affected V5.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X201-3P IRT PRO","version":"affected V5.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X202-2IRT","version":"affected V5.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X202-2P IRT","version":"affected V5.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X202-2P IRT PRO","version":"affected V5.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X204-2","version":"affected All versions < V5.2.6","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X204-2FM","version":"affected All versions < V5.2.6","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X204-2LD","version":"affected All versions < V5.2.6","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X204-2LD TS","version":"affected All versions < V5.2.6","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X204-2TS","version":"affected All versions < V5.2.6","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X204IRT","version":"affected V5.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X204IRT PRO","version":"affected V5.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X206-1","version":"affected All versions < V5.2.6","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X206-1LD","version":"affected All versions < V5.2.6","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X208","version":"affected All versions < V5.2.6","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X208PRO","version":"affected All versions < V5.2.6","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X212-2","version":"affected All versions < V5.2.6","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X212-2LD","version":"affected All versions < V5.2.6","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X216","version":"affected All versions < V5.2.6","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X224","version":"affected All versions < V5.2.6","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X302-7 EEC (230V, coated)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X302-7 EEC (230V)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X302-7 EEC (24V, coated)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X302-7 EEC (24V)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X302-7 EEC (2x 230V, coated)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X302-7 EEC (2x 230V)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X302-7 EEC (2x 24V, coated)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X302-7 EEC (2x 24V)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X304-2FE","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X306-1LD FE","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X307-2 EEC (230V, coated)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X307-2 EEC (230V)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X307-2 EEC (24V, coated)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X307-2 EEC (24V)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X307-2 EEC (2x 230V, coated)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X307-2 EEC (2x 230V)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X307-2 EEC (2x 24V, coated)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X307-2 EEC (2x 24V)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X307-3","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X307-3","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X307-3LD","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X307-3LD","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X308-2","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X308-2","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X308-2LD","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X308-2LD","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X308-2LH","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X308-2LH","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X308-2LH+","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X308-2LH+","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X308-2M","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X308-2M","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X308-2M PoE","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X308-2M PoE","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X308-2M TS","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X308-2M TS","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X310","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X310","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X310FE","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X310FE","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X320-1 FE","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X320-1-2LD FE","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE X408-2","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XF201-3P IRT","version":"affected V5.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XF202-2P IRT","version":"affected V5.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XF204","version":"affected All versions < V5.2.6","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XF204-2","version":"affected All versions < V5.2.6","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XF204-2BA IRT","version":"affected V5.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XF204IRT","version":"affected V5.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XF206-1","version":"affected All versions < V5.2.6","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XF208","version":"affected All versions < V5.2.6","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-12M (230V, ports on front)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-12M (230V, ports on front)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-12M (230V, ports on rear)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-12M (230V, ports on rear)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-12M (24V, ports on front)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-12M (24V, ports on front)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-12M (24V, ports on rear)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-12M (24V, ports on rear)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-12M TS (24V)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-12M TS (24V)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-4M EEC (24V, ports on front)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-4M EEC (24V, ports on front)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-4M EEC (24V, ports on rear)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-4M EEC (24V, ports on rear)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 24V, ports on front)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 24V, ports on front)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 24V, ports on rear)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-4M EEC (2x 24V, ports on rear)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-4M PoE (230V, ports on front)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-4M PoE (230V, ports on rear)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-4M PoE (24V, ports on front)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-4M PoE (24V, ports on rear)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XR324-4M PoE TS (24V, ports on front)","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC CP 1242-7 V2","version":"affected All versions < V3.3.46","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC CP 1243-1","version":"affected All versions < V3.3.46","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC CP 1243-7 LTE EU","version":"affected All versions < V3.3.46","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC CP 1243-7 LTE US","version":"affected All versions < V3.3.46","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC CP 1243-8 IRC","version":"affected All versions < V3.3.46","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC CP 1542SP-1","version":"affected V2.2.28 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC CP 1543-1","version":"affected All versions < V3.0.22","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC CP 1543SP-1","version":"affected V2.2.28 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC CP 1545-1","version":"affected All versions < V1.1","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC PCS neo (Administration Console)","version":"affected V3.1.1 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC Process Historian OPC UA Server","version":"affected V2020 SP1 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1211C AC/DC/Rly","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1211C DC/DC/DC","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1211C DC/DC/Rly","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1212C AC/DC/Rly","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1212C DC/DC/DC","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1212C DC/DC/Rly","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1212FC DC/DC/DC","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1212FC DC/DC/Rly","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1214C AC/DC/Rly","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1214C DC/DC/DC","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1214C DC/DC/Rly","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1214FC DC/DC/DC","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1214FC DC/DC/Rly","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1215C AC/DC/Rly","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1215C DC/DC/DC","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1215C DC/DC/Rly","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1215FC DC/DC/DC","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1215FC DC/DC/Rly","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1200 CPU 1217C DC/DC/DC","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SINEC NMS","version":"affected V1.0 SP3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SINEMA Remote Connect Server","version":"affected V3.1 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SINEMA Server V14","version":"affected * custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SINUMERIK Operate","version":"affected All versions <  V4.95 SP1","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS ET 200SP CP 1543SP-1 ISEC","version":"affected V2.2.28 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL","version":"affected V2.2.28 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS NET CP 1242-7 V2","version":"affected All versions < V3.3.46","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS NET CP 1543-1","version":"affected All versions < V3.0.22","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS NET SCALANCE X308-2","version":"affected V4.1.4 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CP 1243-1","version":"affected All versions < V3.3.46","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CP 1243-1 RAIL","version":"affected All versions < V3.3.46","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1212 AC/DC/RLY","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1212 DC/DC/RLY","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1212 DC/DC/RLY","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1212C AC/DC/RLY","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1212C DC/DC/DC","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1212C DC/DC/DC","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214 AC/DC/RLY","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214 DC/DC/RLY","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214C AC/DC/RLY","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214C AC/DC/RLY","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214C DC/DC/DC","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214C DC/DC/DC","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214C DC/DC/DC","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214C DC/DC/RLY","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214C DC/DC/RLY","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214FC DC/DC/DC","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1214FC DC/DC/RLY","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1215 AC/DC/RLY","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1215 AC/DC/RLY","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1215 DC/DC/DC","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1215 DC/DC/DC","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1215 DC/DC/RLY","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1215 DC/DC/RLY","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1215 DC/DC/RLY","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1215C AC/DC/RLY","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1215C DC/DC/DC","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1200 CPU 1215FC DC/DC/DC","version":"affected V4.5.2 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"TIA Administrator","version":"affected V1.0.7 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Ingo Schwarze","lang":"en"}],"nvd_cpes":[{"cve_year":"2021","cve_id":"3712","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"openssl","cpe5":"openssl","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2021-3712","qid":"159574","title":"Oracle Enterprise Linux Security Update for openssl (ELSA-2021-5226)"},{"cve":"CVE-2021-3712","qid":"159581","title":"Oracle Enterprise Linux Security Update for openssl (ELSA-2021-9632)"},{"cve":"CVE-2021-3712","qid":"159589","title":"Oracle Enterprise Linux Security Update for openssl (ELSA-2022-0064)"},{"cve":"CVE-2021-3712","qid":"159615","title":"Oracle Enterprise Linux Security Update for openssl (ELSA-2022-9017)"},{"cve":"CVE-2021-3712","qid":"159616","title":"Oracle Enterprise Linux Security Update for openssl (ELSA-2022-9023)"},{"cve":"CVE-2021-3712","qid":"178774","title":"Debian Security Update for Open Secure Sockets Layer (OpenSSL) (DSA 4963-1)"},{"cve":"CVE-2021-3712","qid":"178810","title":"Debian Security Update for Open Secure Sockets Layer (OpenSSL) (DLA 2766-1)"},{"cve":"CVE-2021-3712","qid":"178853","title":"Debian Security Update for Open Secure Sockets Layer1.0 (OpenSSLl1.0) (DLA 2774-1)"},{"cve":"CVE-2021-3712","qid":"182376","title":"Debian Security Update for Open Secure Sockets Layer (OpenSSL) (CVE-2021-3712)"},{"cve":"CVE-2021-3712","qid":"198469","title":"Ubuntu Security Notification for Open Secure Sockets Layer (OpenSSL) Vulnerabilities (USN-5051-1)"},{"cve":"CVE-2021-3712","qid":"198473","title":"Ubuntu Security Notification for Open Secure Sockets Layer (OpenSSL) Vulnerability (USN-5051-3)"},{"cve":"CVE-2021-3712","qid":"198517","title":"Ubuntu Security Notification for EDK II Vulnerabilities (USN-5088-1)"},{"cve":"CVE-2021-3712","qid":"239865","title":"Red Hat Update for red hat jboss core services apache Hypertext Transfer Protocol (HTTP) server 2.4.37 sp10 (RHSA-2021:4614)"},{"cve":"CVE-2021-3712","qid":"239977","title":"Red Hat Update for Open Secure Sockets Layer (OpenSSL) (RHSA-2021:5226)"},{"cve":"CVE-2021-3712","qid":"239990","title":"Red Hat Update for Open Secure Sockets Layer (OpenSSL) (RHSA-2022:0064)"},{"cve":"CVE-2021-3712","qid":"330091","title":"IBM Advanced Interactive eXecutive (AIX) Open Secure Sockets Layer (OpenSSL) Out-Of-Bounds Vulnerability (openssl_advisory34)"},{"cve":"CVE-2021-3712","qid":"352846","title":"Amazon Linux Security Advisory for Open Secure Sockets Layer (OpenSSL): ALAS-2021-1541"},{"cve":"CVE-2021-3712","qid":"352853","title":"Amazon Linux Security Advisory for Open Secure Sockets Layer (OpenSSL)11: ALAS2-2021-1714"},{"cve":"CVE-2021-3712","qid":"352867","title":"Amazon Linux Security Advisory for Open Secure Sockets Layer (OpenSSL): ALAS2-2021-1721"},{"cve":"CVE-2021-3712","qid":"353093","title":"Amazon Linux Security Advisory for Open Secure Sockets Layer (OpenSSL) : AL2012-2021-354"},{"cve":"CVE-2021-3712","qid":"357333","title":"Amazon Linux Security Advisory for edk2 : ALAS2-2024-2502"},{"cve":"CVE-2021-3712","qid":"375956","title":"F5 BIG-IP Application Security Manager (ASM), Local Traffic Manager (LTM), Access Policy Manager (APM) Open Secure Sockets Layer (OpenSSL) Vulnerability (K19559038)"},{"cve":"CVE-2021-3712","qid":"375971","title":"Nmap Buffer Overrun Vulnerability"},{"cve":"CVE-2021-3712","qid":"376103","title":"Open Secure Sockets Layer (OpenSSL) Security Update"},{"cve":"CVE-2021-3712","qid":"376202","title":"Reuse"},{"cve":"CVE-2021-3712","qid":"376204","title":"Mysql Workbench Critical Patch Update Oct 2021"},{"cve":"CVE-2021-3712","qid":"376257","title":"Oracle PeopleSoft Enterprise PeopleTools Product Multiple Vulnerabilities (CPUJAN2022)"},{"cve":"CVE-2021-3712","qid":"376363","title":"Oracle MYSQL Connector/ODBC Critical Patch Update (CPU) January 2022 (CPUJAN2022)"},{"cve":"CVE-2021-3712","qid":"377105","title":"Alibaba Cloud Linux Security Update for Open Secure Sockets Layer (OpenSSL) (ALINUX3-SA-2022:0025)"},{"cve":"CVE-2021-3712","qid":"377435","title":"Alibaba Cloud Linux Security Update for Open Secure Sockets Layer (OpenSSL) (ALINUX2-SA-2022:0002)"},{"cve":"CVE-2021-3712","qid":"379452","title":"IBM Cognos Analytics Multiple Vulnerabilities (7123154)"},{"cve":"CVE-2021-3712","qid":"43988","title":"Hewlett Packard Enterprise (HPE) ArubaOS Multiple Vulnerabilities (ARUBA-PSA-2023-002)"},{"cve":"CVE-2021-3712","qid":"500499","title":"Alpine Linux Security Update for Open Secure Sockets Layer (OpenSSL)"},{"cve":"CVE-2021-3712","qid":"500567","title":"Alpine Linux Security Update for Open Secure Sockets Layer (OpenSSL)"},{"cve":"CVE-2021-3712","qid":"500766","title":"Alpine Linux Security Update for openssl"},{"cve":"CVE-2021-3712","qid":"501166","title":"Alpine Linux Security Update for openssl"},{"cve":"CVE-2021-3712","qid":"501985","title":"Alpine Linux Security Update for Open Secure Sockets Layer3 (OpenSSL3)"},{"cve":"CVE-2021-3712","qid":"502904","title":"Alpine Linux Security Update for openssl1.1-compat"},{"cve":"CVE-2021-3712","qid":"504258","title":"Alpine Linux Security Update for openssl"},{"cve":"CVE-2021-3712","qid":"505781","title":"Alpine Linux Security Update for openssl1.1-compat"},{"cve":"CVE-2021-3712","qid":"591054","title":"Mitsubishi Electric MELSOFT GT OPC UA, GT SoftGOT2000 Multiple Vulnerabilities (ICSA-22-130-06)"},{"cve":"CVE-2021-3712","qid":"591311","title":"Bosch Rexroth PRA-ES8P2S Ethernet-Switch Multiple Vulnerabilities (BOSCH-SA-247053-BT)"},{"cve":"CVE-2021-3712","qid":"670831","title":"EulerOS Security Update for Open Secure Sockets Layer (OpenSSL) (EulerOS-SA-2021-2717)"},{"cve":"CVE-2021-3712","qid":"670959","title":"EulerOS Security Update for Open Secure Sockets Layer098e (OpenSSL098e) (EulerOS-SA-2021-2667)"},{"cve":"CVE-2021-3712","qid":"670972","title":"EulerOS Security Update for Compat-Open Secure Sockets Layer (compat-OpenSSL) (EulerOS-SA-2021-2625)"},{"cve":"CVE-2021-3712","qid":"670993","title":"EulerOS Security Update for Open Secure Sockets Layer111d (OpenSSL111d) (EulerOS-SA-2021-2668)"},{"cve":"CVE-2021-3712","qid":"671015","title":"EulerOS Security Update for Open Secure Sockets Layer (OpenSSL) (EulerOS-SA-2021-2692)"},{"cve":"CVE-2021-3712","qid":"671019","title":"EulerOS Security Update for Open Secure Sockets Layer (OpenSSL) (EulerOS-SA-2021-2639)"},{"cve":"CVE-2021-3712","qid":"671031","title":"EulerOS Security Update for Open Secure Sockets Layer (OpenSSL) (EulerOS-SA-2021-2666)"},{"cve":"CVE-2021-3712","qid":"671176","title":"EulerOS Security Update for shim (EulerOS-SA-2021-2927)"},{"cve":"CVE-2021-3712","qid":"671177","title":"EulerOS Security Update for shim (EulerOS-SA-2021-2920)"},{"cve":"CVE-2021-3712","qid":"671245","title":"EulerOS Security Update for Open Secure Sockets Layer098e (OpenSSL098e) (EulerOS-SA-2022-1180)"},{"cve":"CVE-2021-3712","qid":"671248","title":"EulerOS Security Update for Open Secure Sockets Layer (OpenSSL) (EulerOS-SA-2022-1181)"},{"cve":"CVE-2021-3712","qid":"690055","title":"Free Berkeley Software Distribution (FreeBSD) Security Update for Open Secure Sockets Layer (OpenSSL) (96811d4a-04ec-11ec-9b84-d4c9ef517024)"},{"cve":"CVE-2021-3712","qid":"690780","title":"Free Berkeley Software Distribution (FreeBSD) Security Update for mysql (7262f826-795e-11ec-8be6-d4c9ef517024)"},{"cve":"CVE-2021-3712","qid":"710616","title":"Gentoo Linux IBM Spectrum Protect Multiple Vulnerabilities (GLSA 202209-02)"},{"cve":"CVE-2021-3712","qid":"710638","title":"Gentoo Linux Open Secure Sockets Layer (OpenSSL) Multiple Vulnerabilities (GLSA 202210-02)"},{"cve":"CVE-2021-3712","qid":"730206","title":"McAfee Web Gateway Multiple Vulnerabilities (WP-3792, WP-4003, WP-4021, WP-4058, WP-4067)"},{"cve":"CVE-2021-3712","qid":"730377","title":"Dell EMC Precision Rack Security Update for Multiple iDRAC Vulnerabilities (DSA-2021-259) -iDRAC 8,9"},{"cve":"CVE-2021-3712","qid":"751027","title":"SUSE Enterprise Linux Security Update for Open Secure Sockets Layer (OpenSSL) (SUSE-SU-2021:2831-1)"},{"cve":"CVE-2021-3712","qid":"751028","title":"SUSE Enterprise Linux Security Update for Open Secure Sockets Layer (OpenSSL) (SUSE-SU-2021:2829-1)"},{"cve":"CVE-2021-3712","qid":"751029","title":"SUSE Enterprise Linux Security Update for Open Secure Sockets Layer (OpenSSL) (SUSE-SU-2021:2826-1)"},{"cve":"CVE-2021-3712","qid":"751030","title":"SUSE Enterprise Linux Security Update for Open Secure Sockets Layer (OpenSSL) (SUSE-SU-2021:2827-1)"},{"cve":"CVE-2021-3712","qid":"751031","title":"SUSE Enterprise Linux Security Update for Open Secure Sockets Layer (OpenSSL) (SUSE-SU-2021:2833-1)"},{"cve":"CVE-2021-3712","qid":"751032","title":"SUSE Enterprise Linux Security Update for Open Secure Sockets Layer (OpenSSL) (SUSE-SU-2021:2825-1)"},{"cve":"CVE-2021-3712","qid":"751034","title":"OpenSUSE Security Update for openssl-1_0_0 (openSUSE-SU-2021:2827-1)"},{"cve":"CVE-2021-3712","qid":"751035","title":"OpenSUSE Security Update for openssl-1_1 (openSUSE-SU-2021:2830-1)"},{"cve":"CVE-2021-3712","qid":"751049","title":"OpenSUSE Security Update for Open Secure Sockets Layer (OpenSSL) (openSUSE-SU-2021:1189-1)"},{"cve":"CVE-2021-3712","qid":"751050","title":"OpenSUSE Security Update for Open Secure Sockets Layer (OpenSSL) (openSUSE-SU-2021:1188-1)"},{"cve":"CVE-2021-3712","qid":"751059","title":"SUSE Enterprise Linux Security Update for compat- Open Secure Sockets Layer (openssl098) (SUSE-SU-2021:2852-1)"},{"cve":"CVE-2021-3712","qid":"751106","title":"SUSE Enterprise Linux Security Update for Open Secure Sockets Layer-1_1 ( openssl-1_1) (SUSE-SU-2021:2967-1)"},{"cve":"CVE-2021-3712","qid":"751108","title":"SUSE Enterprise Linux Security Update for Open Secure Sockets Layer-1_1 (openssl-1_1) (SUSE-SU-2021:2968-1)"},{"cve":"CVE-2021-3712","qid":"751116","title":"OpenSUSE Security Update for Open Secure Sockets Layer-1_1 (openssl-1_1) (openSUSE-SU-2021:2966-1)"},{"cve":"CVE-2021-3712","qid":"751118","title":"SUSE Enterprise Linux Security Update for Open Secure Sockets Layer-1_1 (OpenSSL-1_1) (SUSE-SU-2021:2996-1)"},{"cve":"CVE-2021-3712","qid":"751119","title":"SUSE Enterprise Linux Security Update for Open Secure Sockets Layer-1_0_0 (OpenSSL-1_0_0) (SUSE-SU-2021:2994-1)"},{"cve":"CVE-2021-3712","qid":"751122","title":"SUSE Enterprise Linux Security Update for Open Secure Sockets Layer-1_0_0 (SUSE-SU-2021:2995-1)"},{"cve":"CVE-2021-3712","qid":"751123","title":"OpenSUSE Security Update for Open Secure Sockets Layer-1_1 (OpenSSL-1_1) (openSUSE-SU-2021:1248-1)"},{"cve":"CVE-2021-3712","qid":"751125","title":"OpenSUSE Security Update for Open Secure Sockets Layer-1_0_0 (OpenSSL-1_0_0) (openSUSE-SU-2021:2994-1)"},{"cve":"CVE-2021-3712","qid":"751128","title":"SUSE Enterprise Linux Security Update for compat-Open Secure Sockets Layer098 (OpenSSL098) (SUSE-SU-2021:3019-1)"},{"cve":"CVE-2021-3712","qid":"751129","title":"OpenSUSE Security Update for Open Secure Sockets Layer-1_0_0 (OpenSSL-1_0_0) (openSUSE-SU-2021:1261-1)"},{"cve":"CVE-2021-3712","qid":"751152","title":"SUSE Enterprise Linux Security Update for Open Secure Sockets Layer (OpenSSL) (SUSE-SU-2021:3144-1)"},{"cve":"CVE-2021-3712","qid":"900406","title":"Common Base Linux Mariner (CBL-Mariner) Security Update for Open Secure Sockets Layer (OpenSSL) (6006)"},{"cve":"CVE-2021-3712","qid":"901882","title":"Common Base Linux Mariner (CBL-Mariner) Security Update for Open Secure Sockets Layer (OpenSSL) (6780-1)"},{"cve":"CVE-2021-3712","qid":"940266","title":"AlmaLinux Security Update for Open Secure Sockets Layer (OpenSSL) (ALSA-2021:5226)"},{"cve":"CVE-2021-3712","qid":"960090","title":"Rocky Linux Security Update for Open Secure Sockets Layer (OpenSSL) (RLSA-2021:5226)"}]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-03T17:01:08.180Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["x_transferred"],"url":"https://www.openssl.org/news/secadv/20210824.txt"},{"tags":["x_transferred"],"url":"https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=94d23fcff9b2a7a8368dfe52214d5c2569882c11"},{"tags":["x_transferred"],"url":"https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=ccb0a11145ee72b042d10593a64eaf9e8a55ec12"},{"name":"DSA-4963","tags":["vendor-advisory","x_transferred"],"url":"https://www.debian.org/security/2021/dsa-4963"},{"name":"[tomcat-dev] 20210825 OpenSSL security announcement - do we need a Tomcat Native release?","tags":["mailing-list","x_transferred"],"url":"https://lists.apache.org/thread.html/r18995de860f0e63635f3008fd2a6aca82394249476d21691e7c59c9e%40%3Cdev.tomcat.apache.org%3E"},{"name":"[oss-security] 20210825 OpenSSL SM2 Decryption Buffer Overflow (CVE-2021-3711), Read buffer overruns processing ASN.1 strings (CVE-2021-3712)","tags":["mailing-list","x_transferred"],"url":"http://www.openwall.com/lists/oss-security/2021/08/26/2"},{"name":"[tomcat-dev] 20210826 Re: OpenSSL security announcement - do we need a Tomcat Native release?","tags":["mailing-list","x_transferred"],"url":"https://lists.apache.org/thread.html/rad5d9f83f0d11fb3f8bb148d179b8a9ad7c6a17f18d70e5805a713d1%40%3Cdev.tomcat.apache.org%3E"},{"tags":["x_transferred"],"url":"https://security.netapp.com/advisory/ntap-20210827-0010/"},{"name":"[debian-lts-announce] 20210926 [SECURITY] [DLA 2766-1] openssl security update","tags":["mailing-list","x_transferred"],"url":"https://lists.debian.org/debian-lts-announce/2021/09/msg00014.html"},{"name":"[debian-lts-announce] 20210930 [SECURITY] [DLA 2774-1] openssl1.0 security update","tags":["mailing-list","x_transferred"],"url":"https://lists.debian.org/debian-lts-announce/2021/09/msg00021.html"},{"tags":["x_transferred"],"url":"https://www.oracle.com/security-alerts/cpuoct2021.html"},{"tags":["x_transferred"],"url":"https://www.tenable.com/security/tns-2021-16"},{"tags":["x_transferred"],"url":"https://kc.mcafee.com/corporate/index?page=content&id=SB10366"},{"tags":["x_transferred"],"url":"https://www.oracle.com/security-alerts/cpujan2022.html"},{"tags":["x_transferred"],"url":"https://www.tenable.com/security/tns-2022-02"},{"tags":["x_transferred"],"url":"https://www.oracle.com/security-alerts/cpuapr2022.html"},{"tags":["x_transferred"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"},{"tags":["x_transferred"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-244969.pdf"},{"name":"GLSA-202209-02","tags":["vendor-advisory","x_transferred"],"url":"https://security.gentoo.org/glsa/202209-02"},{"name":"GLSA-202210-02","tags":["vendor-advisory","x_transferred"],"url":"https://security.gentoo.org/glsa/202210-02"},{"tags":["x_transferred"],"url":"https://security.netapp.com/advisory/ntap-20240621-0006/"}],"title":"CVE Program Container"},{"affected":[{"defaultStatus":"unknown","product":"BFCClient","vendor":"Siemens","versions":[{"lessThan":"V2.17","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"Industrial Edge - Machine Insight App","vendor":"Siemens","versions":[{"lessThan":"*","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"Industrial Edge - PROFINET IO Connector","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V1.1.1"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM RM1224 LTE(4G) EU","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V7.1"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM RM1224 LTE(4G) NAM","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V7.1"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX MX5000","vendor":"Siemens","versions":[{"lessThan":"V2.15.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX MX5000RE","vendor":"Siemens","versions":[{"lessThan":"V2.15.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1400","vendor":"Siemens","versions":[{"lessThan":"V2.15.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1500","vendor":"Siemens","versions":[{"lessThan":"V2.15.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1501","vendor":"Siemens","versions":[{"lessThan":"V2.15.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1510","vendor":"Siemens","versions":[{"lessThan":"V2.15.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1511","vendor":"Siemens","versions":[{"lessThan":"V2.15.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1512","vendor":"Siemens","versions":[{"lessThan":"V2.15.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1524","vendor":"Siemens","versions":[{"lessThan":"V2.15.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1536","vendor":"Siemens","versions":[{"lessThan":"V2.15.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX5000","vendor":"Siemens","versions":[{"lessThan":"V2.15.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE M804PB","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V7.1"}]},{"defaultStatus":"unknown","product":"SCALANCE M812-1 ADSL-Router","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V7.1"}]},{"defaultStatus":"unknown","product":"SCALANCE M812-1 ADSL-Router","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V7.1"}]},{"defaultStatus":"unknown","product":"SCALANCE M816-1 ADSL-Router","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V7.1"}]},{"defaultStatus":"unknown","product":"SCALANCE M816-1 ADSL-Router","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V7.1"}]},{"defaultStatus":"unknown","product":"SCALANCE M826-2 SHDSL-Router","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V7.1"}]},{"defaultStatus":"unknown","product":"SCALANCE M874-2","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V7.1"}]},{"defaultStatus":"unknown","product":"SCALANCE M874-3","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V7.1"}]},{"defaultStatus":"unknown","product":"SCALANCE M876-3","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V7.1"}]},{"defaultStatus":"unknown","product":"SCALANCE M876-3 (ROK)","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V7.1"}]},{"defaultStatus":"unknown","product":"SCALANCE M876-4 (EU)","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V7.1"}]},{"defaultStatus":"unknown","product":"SCALANCE M876-4 (NAM)","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V7.1"}]},{"defaultStatus":"unknown","product":"SCALANCE MUM853-1 (EU)","vendor":"Siemens","versions":[{"lessThan":"V7.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE MUM856-1 (EU)","vendor":"Siemens","versions":[{"lessThan":"V7.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE MUM856-1 (RoW)","vendor":"Siemens","versions":[{"lessThan":"V7.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE S615 LAN-Router","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V7.1"}]},{"defaultStatus":"unknown","product":"SCALANCE SC622-2C","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V2.3"}]},{"defaultStatus":"unknown","product":"SCALANCE SC632-2C","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V2.3"}]},{"defaultStatus":"unknown","product":"SCALANCE SC636-2C","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V2.3"}]},{"defaultStatus":"unknown","product":"SCALANCE SC642-2C","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V2.3"}]},{"defaultStatus":"unknown","product":"SCALANCE SC646-2C","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V2.3"}]},{"defaultStatus":"unknown","product":"SCALANCE W1748-1 M12","vendor":"Siemens","versions":[{"lessThan":"V3.0.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W1748-1 M12","vendor":"Siemens","versions":[{"lessThan":"V3.0.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W1788-1 M12","vendor":"Siemens","versions":[{"lessThan":"V3.0.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W1788-2 EEC M12","vendor":"Siemens","versions":[{"lessThan":"V3.0.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W1788-2 M12","vendor":"Siemens","versions":[{"lessThan":"V3.0.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W1788-2IA M12","vendor":"Siemens","versions":[{"lessThan":"V3.0.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W721-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W721-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W721-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W721-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45 (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45 (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W738-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W738-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W738-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W738-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W761-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W761-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W761-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W761-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45 (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45 (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12 EEC (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12 EEC (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 SFP","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 SFP","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 SFP","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 SFP","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2IA RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2IA RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2IA RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2IA RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE WAM766-1","vendor":"Siemens","versions":[{"lessThan":"V1.2.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE WAM766-1 (US)","vendor":"Siemens","versions":[{"lessThan":"V1.2.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE WAM766-1 EEC","vendor":"Siemens","versions":[{"lessThan":"V1.2.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE WAM766-1 EEC (US)","vendor":"Siemens","versions":[{"lessThan":"V1.2.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE WUM766-1","vendor":"Siemens","versions":[{"lessThan":"V1.2.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE WUM766-1 (USA)","vendor":"Siemens","versions":[{"lessThan":"V1.2.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X200-4P IRT","vendor":"Siemens","versions":[{"lessThan":"V5.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X201-3P IRT","vendor":"Siemens","versions":[{"lessThan":"V5.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X201-3P IRT PRO","vendor":"Siemens","versions":[{"lessThan":"V5.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X202-2IRT","vendor":"Siemens","versions":[{"lessThan":"V5.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X202-2P IRT","vendor":"Siemens","versions":[{"lessThan":"V5.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X202-2P IRT PRO","vendor":"Siemens","versions":[{"lessThan":"V5.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X204-2","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.6"}]},{"defaultStatus":"unknown","product":"SCALANCE X204-2FM","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.6"}]},{"defaultStatus":"unknown","product":"SCALANCE X204-2LD","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.6"}]},{"defaultStatus":"unknown","product":"SCALANCE X204-2LD TS","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.6"}]},{"defaultStatus":"unknown","product":"SCALANCE X204-2TS","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.6"}]},{"defaultStatus":"unknown","product":"SCALANCE X204IRT","vendor":"Siemens","versions":[{"lessThan":"V5.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X204IRT PRO","vendor":"Siemens","versions":[{"lessThan":"V5.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X206-1","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.6"}]},{"defaultStatus":"unknown","product":"SCALANCE X206-1LD","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.6"}]},{"defaultStatus":"unknown","product":"SCALANCE X208","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.6"}]},{"defaultStatus":"unknown","product":"SCALANCE X208PRO","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.6"}]},{"defaultStatus":"unknown","product":"SCALANCE X212-2","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.6"}]},{"defaultStatus":"unknown","product":"SCALANCE X212-2LD","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.6"}]},{"defaultStatus":"unknown","product":"SCALANCE X216","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.6"}]},{"defaultStatus":"unknown","product":"SCALANCE X224","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.6"}]},{"defaultStatus":"unknown","product":"SCALANCE X302-7 EEC (230V, coated)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X302-7 EEC (230V)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X302-7 EEC (24V, coated)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X302-7 EEC (24V)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X302-7 EEC (2x 230V, coated)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X302-7 EEC (2x 230V)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X302-7 EEC (2x 24V, coated)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X302-7 EEC (2x 24V)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X304-2FE","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X306-1LD FE","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X307-2 EEC (230V, coated)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X307-2 EEC (230V)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X307-2 EEC (24V, coated)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X307-2 EEC (24V)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X307-2 EEC (2x 230V, coated)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X307-2 EEC (2x 230V)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X307-2 EEC (2x 24V, coated)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X307-2 EEC (2x 24V)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X307-3","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X307-3","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X307-3LD","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X307-3LD","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X308-2","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X308-2","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X308-2LD","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X308-2LD","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X308-2LH","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X308-2LH","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X308-2LH+","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X308-2LH+","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X308-2M","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X308-2M","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X308-2M PoE","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X308-2M PoE","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X308-2M TS","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X308-2M TS","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X310","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X310","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X310FE","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X310FE","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X320-1 FE","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X320-1-2LD FE","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE X408-2","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XF201-3P IRT","vendor":"Siemens","versions":[{"lessThan":"V5.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XF202-2P IRT","vendor":"Siemens","versions":[{"lessThan":"V5.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XF204","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.6"}]},{"defaultStatus":"unknown","product":"SCALANCE XF204-2","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.6"}]},{"defaultStatus":"unknown","product":"SCALANCE XF204-2BA IRT","vendor":"Siemens","versions":[{"lessThan":"V5.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XF204IRT","vendor":"Siemens","versions":[{"lessThan":"V5.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XF206-1","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.6"}]},{"defaultStatus":"unknown","product":"SCALANCE XF208","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V5.2.6"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-12M (230V, ports on front)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-12M (230V, ports on front)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-12M (230V, ports on rear)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-12M (230V, ports on rear)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-12M (24V, ports on front)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-12M (24V, ports on front)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-12M (24V, ports on rear)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-12M (24V, ports on rear)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-12M TS (24V)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-12M TS (24V)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-4M EEC (24V, ports on front)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-4M EEC (24V, ports on front)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-4M EEC (24V, ports on rear)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-4M EEC (24V, ports on rear)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-4M EEC (2x 24V, ports on front)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-4M EEC (2x 24V, ports on front)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-4M EEC (2x 24V, ports on rear)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-4M EEC (2x 24V, ports on rear)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-4M PoE (230V, ports on front)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-4M PoE (230V, ports on rear)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-4M PoE (24V, ports on front)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-4M PoE (24V, ports on rear)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XR324-4M PoE TS (24V, ports on front)","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC CP 1242-7 V2","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V3.3.46"}]},{"defaultStatus":"unknown","product":"SIMATIC CP 1243-1","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V3.3.46"}]},{"defaultStatus":"unknown","product":"SIMATIC CP 1243-7 LTE EU","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V3.3.46"}]},{"defaultStatus":"unknown","product":"SIMATIC CP 1243-7 LTE US","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V3.3.46"}]},{"defaultStatus":"unknown","product":"SIMATIC CP 1243-8 IRC","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V3.3.46"}]},{"defaultStatus":"unknown","product":"SIMATIC CP 1542SP-1","vendor":"Siemens","versions":[{"lessThan":"V2.2.28","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC CP 1543-1","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V3.0.22"}]},{"defaultStatus":"unknown","product":"SIMATIC CP 1543SP-1","vendor":"Siemens","versions":[{"lessThan":"V2.2.28","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC CP 1545-1","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V1.1"}]},{"defaultStatus":"unknown","product":"SIMATIC PCS neo (Administration Console)","vendor":"Siemens","versions":[{"lessThan":"V3.1.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC Process Historian OPC UA Server","vendor":"Siemens","versions":[{"lessThan":"V2020 SP1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1200 CPU 1211C AC/DC/Rly","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1200 CPU 1211C DC/DC/DC","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1200 CPU 1211C DC/DC/Rly","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1200 CPU 1212C AC/DC/Rly","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1200 CPU 1212C DC/DC/DC","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1200 CPU 1212C DC/DC/Rly","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1200 CPU 1212FC DC/DC/DC","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1200 CPU 1212FC DC/DC/Rly","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1200 CPU 1214C AC/DC/Rly","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1200 CPU 1214C DC/DC/DC","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1200 CPU 1214C DC/DC/Rly","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1200 CPU 1214FC DC/DC/DC","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1200 CPU 1214FC DC/DC/Rly","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1200 CPU 1215C AC/DC/Rly","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1200 CPU 1215C DC/DC/DC","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1200 CPU 1215C DC/DC/Rly","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1200 CPU 1215FC DC/DC/DC","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1200 CPU 1215FC DC/DC/Rly","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1200 CPU 1217C DC/DC/DC","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SINEC NMS","vendor":"Siemens","versions":[{"lessThan":"V1.0 SP3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SINEMA Remote Connect Server","vendor":"Siemens","versions":[{"lessThan":"V3.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SINEMA Server V14","vendor":"Siemens","versions":[{"lessThan":"*","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SINUMERIK Operate","vendor":"Siemens","versions":[{"status":"affected","version":"All versions <  V4.95 SP1"}]},{"defaultStatus":"unknown","product":"SIPLUS ET 200SP CP 1543SP-1 ISEC","vendor":"Siemens","versions":[{"lessThan":"V2.2.28","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL","vendor":"Siemens","versions":[{"lessThan":"V2.2.28","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS NET CP 1242-7 V2","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V3.3.46"}]},{"defaultStatus":"unknown","product":"SIPLUS NET CP 1543-1","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V3.0.22"}]},{"defaultStatus":"unknown","product":"SIPLUS NET SCALANCE X308-2","vendor":"Siemens","versions":[{"lessThan":"V4.1.4","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CP 1243-1","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V3.3.46"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CP 1243-1 RAIL","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V3.3.46"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1212 AC/DC/RLY","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1212 DC/DC/RLY","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1212 DC/DC/RLY","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1212C AC/DC/RLY","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1212C DC/DC/DC","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1212C DC/DC/DC","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1214 AC/DC/RLY","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1214 DC/DC/RLY","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1214C AC/DC/RLY","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1214C AC/DC/RLY","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1214C DC/DC/DC","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1214C DC/DC/DC","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1214C DC/DC/DC","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1214C DC/DC/RLY","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1214C DC/DC/RLY","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1214FC DC/DC/DC","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1214FC DC/DC/RLY","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1215 AC/DC/RLY","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1215 AC/DC/RLY","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1215 DC/DC/DC","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1215 DC/DC/DC","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1215 DC/DC/RLY","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1215 DC/DC/RLY","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1215 DC/DC/RLY","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1215C AC/DC/RLY","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1215C DC/DC/DC","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1200 CPU 1215FC DC/DC/DC","vendor":"Siemens","versions":[{"lessThan":"V4.5.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"TIA Administrator","vendor":"Siemens","versions":[{"lessThan":"V1.0.7","status":"affected","version":"0","versionType":"custom"}]}],"providerMetadata":{"dateUpdated":"2026-04-14T08:57:51.339Z","orgId":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","shortName":"siemens-SADP"},"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-244969.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-389290.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-028723.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-019200.html"}],"x_adpType":"supplier"},{"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.4,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H","version":"3.1"}},{"other":{"content":{"id":"CVE-2021-3712","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-04-16T14:11:09.557845Z","version":"2.0.3"},"type":"ssvc"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-125","description":"CWE-125 Out-of-bounds Read","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-04-16T14:11:16.454Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"product":"OpenSSL","vendor":"OpenSSL","versions":[{"status":"affected","version":"Fixed in OpenSSL 1.1.1l (Affected 1.1.1-1.1.1k)"},{"status":"affected","version":"Fixed in OpenSSL 1.0.2za (Affected 1.0.2-1.0.2y)"}]}],"credits":[{"lang":"en","value":"Ingo Schwarze"}],"datePublic":"2021-08-24T00:00:00.000Z","descriptions":[{"lang":"en","value":"ASN.1 strings are represented internally within OpenSSL as an ASN1_STRING structure which contains a buffer holding the string data and a field holding the buffer length. This contrasts with normal C strings which are repesented as a buffer for the string data which is terminated with a NUL (0) byte. Although not a strict requirement, ASN.1 strings that are parsed using OpenSSL's own \"d2i\" functions (and other similar parsing functions) as well as any string whose value has been set with the ASN1_STRING_set() function will additionally NUL terminate the byte array in the ASN1_STRING structure. However, it is possible for applications to directly construct valid ASN1_STRING structures which do not NUL terminate the byte array by directly setting the \"data\" and \"length\" fields in the ASN1_STRING array. This can also happen by using the ASN1_STRING_set0() function. Numerous OpenSSL functions that print ASN.1 data have been found to assume that the ASN1_STRING byte array will be NUL terminated, even though this is not guaranteed for strings that have been directly constructed. Where an application requests an ASN.1 structure to be printed, and where that ASN.1 structure contains ASN1_STRINGs that have been directly constructed by the application without NUL terminating the \"data\" field, then a read buffer overrun can occur. The same thing can also occur during name constraints processing of certificates (for example if a certificate has been directly constructed by the application instead of loading it via the OpenSSL parsing functions, and the certificate contains non NUL terminated ASN1_STRING structures). It can also occur in the X509_get1_email(), X509_REQ_get1_email() and X509_get1_ocsp() functions. If a malicious actor can cause an application to directly construct an ASN1_STRING and then process it through one of the affected OpenSSL functions then this issue could be hit. This might result in a crash (causing a Denial of Service attack). It could also result in the disclosure of private memory contents (such as private keys, or sensitive plaintext). Fixed in OpenSSL 1.1.1l (Affected 1.1.1-1.1.1k). Fixed in OpenSSL 1.0.2za (Affected 1.0.2-1.0.2y)."}],"metrics":[{"other":{"content":{"lang":"eng","url":"https://www.openssl.org/policies/secpolicy.html#Moderate","value":"Moderate"},"type":"unknown"}}],"problemTypes":[{"descriptions":[{"description":"Buffer overflow","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2024-06-21T19:07:21.902Z","orgId":"3a12439a-ef3a-4c79-92e6-6081a721f1e5","shortName":"openssl"},"references":[{"url":"https://www.openssl.org/news/secadv/20210824.txt"},{"url":"https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=94d23fcff9b2a7a8368dfe52214d5c2569882c11"},{"url":"https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=ccb0a11145ee72b042d10593a64eaf9e8a55ec12"},{"name":"DSA-4963","tags":["vendor-advisory"],"url":"https://www.debian.org/security/2021/dsa-4963"},{"name":"[tomcat-dev] 20210825 OpenSSL security announcement - do we need a Tomcat Native release?","tags":["mailing-list"],"url":"https://lists.apache.org/thread.html/r18995de860f0e63635f3008fd2a6aca82394249476d21691e7c59c9e%40%3Cdev.tomcat.apache.org%3E"},{"name":"[oss-security] 20210825 OpenSSL SM2 Decryption Buffer Overflow (CVE-2021-3711), Read buffer overruns processing ASN.1 strings (CVE-2021-3712)","tags":["mailing-list"],"url":"http://www.openwall.com/lists/oss-security/2021/08/26/2"},{"name":"[tomcat-dev] 20210826 Re: OpenSSL security announcement - do we need a Tomcat Native release?","tags":["mailing-list"],"url":"https://lists.apache.org/thread.html/rad5d9f83f0d11fb3f8bb148d179b8a9ad7c6a17f18d70e5805a713d1%40%3Cdev.tomcat.apache.org%3E"},{"url":"https://security.netapp.com/advisory/ntap-20210827-0010/"},{"name":"[debian-lts-announce] 20210926 [SECURITY] [DLA 2766-1] openssl security update","tags":["mailing-list"],"url":"https://lists.debian.org/debian-lts-announce/2021/09/msg00014.html"},{"name":"[debian-lts-announce] 20210930 [SECURITY] [DLA 2774-1] openssl1.0 security update","tags":["mailing-list"],"url":"https://lists.debian.org/debian-lts-announce/2021/09/msg00021.html"},{"url":"https://www.oracle.com/security-alerts/cpuoct2021.html"},{"url":"https://www.tenable.com/security/tns-2021-16"},{"url":"https://kc.mcafee.com/corporate/index?page=content&id=SB10366"},{"url":"https://www.oracle.com/security-alerts/cpujan2022.html"},{"url":"https://www.tenable.com/security/tns-2022-02"},{"url":"https://www.oracle.com/security-alerts/cpuapr2022.html"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-244969.pdf"},{"name":"GLSA-202209-02","tags":["vendor-advisory"],"url":"https://security.gentoo.org/glsa/202209-02"},{"name":"GLSA-202210-02","tags":["vendor-advisory"],"url":"https://security.gentoo.org/glsa/202210-02"},{"url":"https://security.netapp.com/advisory/ntap-20240621-0006/"}],"title":"Read buffer overruns processing ASN.1 strings"}},"cveMetadata":{"assignerOrgId":"3a12439a-ef3a-4c79-92e6-6081a721f1e5","assignerShortName":"openssl","cveId":"CVE-2021-3712","datePublished":"2021-08-24T14:50:14.704Z","dateReserved":"2021-08-16T00:00:00.000Z","dateUpdated":"2026-04-16T14:11:16.454Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2021-08-24 15:15:09","lastModifiedDate":"2026-04-16 15:16:45","problem_types":["CWE-125","Buffer overflow","CWE-125 CWE-125 Out-of-bounds Read"],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H","baseScore":7.4,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":2.2,"impactScore":5.2},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H","baseScore":7.4,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":2.2,"impactScore":5.2}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:N/A:P","baseScore":5.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":4.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:*","versionStartIncluding":"1.0.2","versionEndExcluding":"1.0.2za","matchCriteriaId":"20353A2F-46B5-4C46-B562-42CD6E2B248B"},{"vulnerable":true,"criteria":"cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:*","versionStartIncluding":"1.1.1","versionEndExcluding":"1.1.1l","matchCriteriaId":"A9592A08-7FF0-490F-B684-6EA8E49F36C7"}]}]},{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*","matchCriteriaId":"DEECE5FC-CACF-4496-A3E7-164736409252"},{"vulnerable":true,"criteria":"cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*","matchCriteriaId":"07B237A9-69A3-4A9C-9DA0-4E06BD37AE73"},{"vulnerable":true,"criteria":"cpe:2.3:o:debian:debian_linux:11.0:*:*:*:*:*:*:*","matchCriteriaId":"FA6FEEC2-9F11-4643-8827-749718254FED"}]}]},{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:netapp:clustered_data_ontap:-:*:*:*:*:*:*:*","matchCriteriaId":"1FE996B1-6951-4F85-AA58-B99A379D2163"},{"vulnerable":true,"criteria":"cpe:2.3:a:netapp:clustered_data_ontap_antivirus_connector:-:*:*:*:*:*:*:*","matchCriteriaId":"62347994-1353-497C-9C4A-D5D8D95F67E8"},{"vulnerable":true,"criteria":"cpe:2.3:a:netapp:e-series_santricity_os_controller:*:*:*:*:*:*:*:*","versionStartIncluding":"11.0","versionEndIncluding":"11.50.2","matchCriteriaId":"433D435D-13D0-4EAA-ACD9-DD88DA712D00"},{"vulnerable":true,"criteria":"cpe:2.3:a:netapp:hci_management_node:-:*:*:*:*:*:*:*","matchCriteriaId":"A3C19813-E823-456A-B1CE-EC0684CE1953"},{"vulnerable":true,"criteria":"cpe:2.3:a:netapp:manageability_software_development_kit:-:*:*:*:*:*:*:*","matchCriteriaId":"D39DCAE7-494F-40B2-867F-6C6A077939DD"},{"vulnerable":true,"criteria":"cpe:2.3:a:netapp:santricity_smi-s_provider:-:*:*:*:*:*:*:*","matchCriteriaId":"361B791A-D336-4431-8F68-8135BEFFAEA2"},{"vulnerable":true,"criteria":"cpe:2.3:a:netapp:solidfire:-:*:*:*:*:*:*:*","matchCriteriaId":"A6E9EF0C-AFA8-4F7B-9FDC-1E0F7C26E737"},{"vulnerable":true,"criteria":"cpe:2.3:a:netapp:storage_encryption:-:*:*:*:*:*:*:*","matchCriteriaId":"2D82795C-F1ED-4D2C-B578-75B9EECBB99C"}]}]},{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:mcafee:epolicy_orchestrator:*:*:*:*:*:*:*:*","versionEndExcluding":"5.10.0","matchCriteriaId":"A30F7908-5AF6-4761-BC6A-4C18EFAE48E5"},{"vulnerable":true,"criteria":"cpe:2.3:a:mcafee:epolicy_orchestrator:5.10.0:-:*:*:*:*:*:*","matchCriteriaId":"0F30D3AF-4FA3-4B7A-BE04-C24E2EA19A95"},{"vulnerable":true,"criteria":"cpe:2.3:a:mcafee:epolicy_orchestrator:5.10.0:update_1:*:*:*:*:*:*","matchCriteriaId":"7B00DDE7-7002-45BE-8EDE-65D964922CB0"},{"vulnerable":true,"criteria":"cpe:2.3:a:mcafee:epolicy_orchestrator:5.10.0:update_10:*:*:*:*:*:*","matchCriteriaId":"DB88C165-BB24-49FB-AAF6-087A766D5AD1"},{"vulnerable":true,"criteria":"cpe:2.3:a:mcafee:epolicy_orchestrator:5.10.0:update_2:*:*:*:*:*:*","matchCriteriaId":"FF806B52-DAD5-4D12-8BB6-3CBF9DC6B8DF"},{"vulnerable":true,"criteria":"cpe:2.3:a:mcafee:epolicy_orchestrator:5.10.0:update_3:*:*:*:*:*:*","matchCriteriaId":"7DE847E0-431D-497D-9C57-C4E59749F6A0"},{"vulnerable":true,"criteria":"cpe:2.3:a:mcafee:epolicy_orchestrator:5.10.0:update_4:*:*:*:*:*:*","matchCriteriaId":"46385384-5561-40AA-9FDE-A2DE4FDFAD3E"},{"vulnerable":true,"criteria":"cpe:2.3:a:mcafee:epolicy_orchestrator:5.10.0:update_5:*:*:*:*:*:*","matchCriteriaId":"B7CA7CA6-7CF2-48F6-81B5-69BA0A37EF4E"},{"vulnerable":true,"criteria":"cpe:2.3:a:mcafee:epolicy_orchestrator:5.10.0:update_6:*:*:*:*:*:*","matchCriteriaId":"9E4E5481-1070-4E1F-8679-1985DE4E785A"},{"vulnerable":true,"criteria":"cpe:2.3:a:mcafee:epolicy_orchestrator:5.10.0:update_7:*:*:*:*:*:*","matchCriteriaId":"D9EEA681-67FF-43B3-8610-0FA17FD279E5"},{"vulnerable":true,"criteria":"cpe:2.3:a:mcafee:epolicy_orchestrator:5.10.0:update_8:*:*:*:*:*:*","matchCriteriaId":"C33BA8EA-793D-4E79-BE9C-235ACE717216"},{"vulnerable":true,"criteria":"cpe:2.3:a:mcafee:epolicy_orchestrator:5.10.0:update_9:*:*:*:*:*:*","matchCriteriaId":"823DBE80-CB8D-4981-AE7C-28F3FDD40451"}]}]},{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:tenable:nessus_network_monitor:*:*:*:*:*:*:*:*","versionEndExcluding":"6.0.0","matchCriteriaId":"9E0DE4DE-9454-4E8D-9E00-3CBCDD8C142A"},{"vulnerable":true,"criteria":"cpe:2.3:a:tenable:tenable.sc:*:*:*:*:*:*:*:*","versionStartIncluding":"5.16.0","versionEndIncluding":"5.19.1","matchCriteriaId":"8D977244-DC29-4301-8D89-0BD01BC328B8"}]}]},{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:essbase:*:*:*:*:*:*:*:*","versionEndExcluding":"11.1.2.4.047","matchCriteriaId":"6A0BD5BD-E2F8-4B4E-B5CF-9787E6F2E4AE"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:essbase:*:*:*:*:*:*:*:*","versionStartIncluding":"21.0","versionEndExcluding":"21.3","matchCriteriaId":"3197F464-F0A5-4BD4-9068-65CD448D8F4C"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:essbase:21.3:*:*:*:*:*:*:*","matchCriteriaId":"15DD67FD-CE98-4556-A036-B2970935AF4D"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:mysql_connectors:*:*:*:*:*:*:*:*","versionEndIncluding":"8.0.27","matchCriteriaId":"AE23C7E1-F849-411D-850F-A504D4BA3414"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:mysql_enterprise_monitor:*:*:*:*:*:*:*:*","versionEndIncluding":"8.0.25","matchCriteriaId":"88627B99-16DC-4878-A63A-A40F6FC1F477"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*","versionStartIncluding":"5.7.0","versionEndIncluding":"5.7.35","matchCriteriaId":"E667933A-37EA-4BC2-9180-C3B4B7038866"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*","versionStartIncluding":"8.0.0","versionEndIncluding":"8.0.26","matchCriteriaId":"709E83B4-8C66-4255-870B-2F72B37BA8C6"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:mysql_workbench:*:*:*:*:*:*:*:*","versionEndIncluding":"8.0.26","matchCriteriaId":"EED6C8C2-F986-4CFD-A343-AD2340F850F2"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.57:*:*:*:*:*:*:*","matchCriteriaId":"7E1E416B-920B-49A0-9523-382898C2979D"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.58:*:*:*:*:*:*:*","matchCriteriaId":"D9DB4A14-2EF5-4B54-95D2-75E6CF9AA0A9"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.59:*:*:*:*:*:*:*","matchCriteriaId":"C8AF00C6-B97F-414D-A8DF-057E6BFD8597"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:secure_backup:18.1.0.1.0:*:*:*:*:*:*:*","matchCriteriaId":"E8929B61-16EC-4FE0-98A5-1CC7CC7FD9CC"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:zfs_storage_appliance_kit:8.8:*:*:*:*:*:*:*","matchCriteriaId":"D3E503FB-6279-4D4A-91D8-E237ECF9D2B0"}]}]},{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinec_infrastructure_network_services:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.1.1","matchCriteriaId":"B0F46497-4AB0-49A7-9453-CC26837BF253"}]}]},{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:communications_cloud_native_core_console:1.9.0:*:*:*:*:*:*:*","matchCriteriaId":"DAAB7154-4DE8-4806-86D0-C1D33B84417B"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:communications_cloud_native_core_security_edge_protection_proxy:1.7.0:*:*:*:*:*:*:*","matchCriteriaId":"BD4349FE-EEF8-489A-8ABF-5FCD55EC6DE0"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:communications_cloud_native_core_unified_data_repository:1.15.0:*:*:*:*:*:*:*","matchCriteriaId":"C6EAA723-2A23-4151-930B-86ACF9CC1C0C"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:communications_session_border_controller:8.4:*:*:*:*:*:*:*","matchCriteriaId":"9C416FD3-2E2F-4BBC-BD5F-F896825883F4"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:communications_session_border_controller:9.0:*:*:*:*:*:*:*","matchCriteriaId":"D886339E-EDB2-4879-BD54-1800E4CA9CAE"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:communications_unified_session_manager:8.2.5:*:*:*:*:*:*:*","matchCriteriaId":"FB468FEE-A0F4-49A0-BBEE-10D0733C87D4"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:communications_unified_session_manager:8.4.5:*:*:*:*:*:*:*","matchCriteriaId":"CC5C177E-0C77-48C9-847A-A9E5AA7DBC1F"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:enterprise_communications_broker:3.2.0:*:*:*:*:*:*:*","matchCriteriaId":"348EEE70-E114-4720-AAAF-E77DE5C9A2D1"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:enterprise_communications_broker:3.3.0:*:*:*:*:*:*:*","matchCriteriaId":"3DCDD73B-57B1-4580-B922-5662E3AC13B6"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:enterprise_session_border_controller:8.4:*:*:*:*:*:*:*","matchCriteriaId":"7015A8CB-8FA6-423E-8307-BD903244F517"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:enterprise_session_border_controller:9.0:*:*:*:*:*:*:*","matchCriteriaId":"F9A4E206-56C7-4578-AC9C-088B0C8D9CFE"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:health_sciences_inform_publisher:6.2.1.0:*:*:*:*:*:*:*","matchCriteriaId":"0D1E6A38-4CBD-42E9-B2D2-11AEF157822F"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:health_sciences_inform_publisher:6.3.1.1:*:*:*:*:*:*:*","matchCriteriaId":"5D105A5B-0AA8-4782-B804-CB1384F85884"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:jd_edwards_enterpriseone_tools:*:*:*:*:*:*:*:*","versionEndExcluding":"9.2.6.3","matchCriteriaId":"BE34D4F7-5C18-4578-8D0A-722FDF931333"},{"vulnerable":true,"criteria":"cpe:2.3:a:oracle:jd_edwards_world_security:a9.4:*:*:*:*:*:*:*","matchCriteriaId":"0B1CAD50-749F-4ADB-A046-BF3585677A58"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"3712","Ordinal":"1","Title":"Read buffer overruns processing ASN.1 strings","CVE":"CVE-2021-3712","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"3712","Ordinal":"1","NoteData":"ASN.1 strings are represented internally within OpenSSL as an ASN1_STRING structure which contains a buffer holding the string data and a field holding the buffer length. This contrasts with normal C strings which are repesented as a buffer for the string data which is terminated with a NUL (0) byte. Although not a strict requirement, ASN.1 strings that are parsed using OpenSSL's own \"d2i\" functions (and other similar parsing functions) as well as any string whose value has been set with the ASN1_STRING_set() function will additionally NUL terminate the byte array in the ASN1_STRING structure. However, it is possible for applications to directly construct valid ASN1_STRING structures which do not NUL terminate the byte array by directly setting the \"data\" and \"length\" fields in the ASN1_STRING array. This can also happen by using the ASN1_STRING_set0() function. Numerous OpenSSL functions that print ASN.1 data have been found to assume that the ASN1_STRING byte array will be NUL terminated, even though this is not guaranteed for strings that have been directly constructed. Where an application requests an ASN.1 structure to be printed, and where that ASN.1 structure contains ASN1_STRINGs that have been directly constructed by the application without NUL terminating the \"data\" field, then a read buffer overrun can occur. The same thing can also occur during name constraints processing of certificates (for example if a certificate has been directly constructed by the application instead of loading it via the OpenSSL parsing functions, and the certificate contains non NUL terminated ASN1_STRING structures). It can also occur in the X509_get1_email(), X509_REQ_get1_email() and X509_get1_ocsp() functions. If a malicious actor can cause an application to directly construct an ASN1_STRING and then process it through one of the affected OpenSSL functions then this issue could be hit. This might result in a crash (causing a Denial of Service attack). It could also result in the disclosure of private memory contents (such as private keys, or sensitive plaintext). Fixed in OpenSSL 1.1.1l (Affected 1.1.1-1.1.1k). Fixed in OpenSSL 1.0.2za (Affected 1.0.2-1.0.2y).","Type":"Description","Title":"Read buffer overruns processing ASN.1 strings"},{"CveYear":"2021","CveId":"3712","Ordinal":"2","NoteData":"2021-08-24","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"3712","Ordinal":"3","NoteData":"2022-02-08","Type":"Other","Title":"Modified"}]}}}