{"api_version":"1","generated_at":"2026-07-23T23:58:11+00:00","cve":"CVE-2021-37207","urls":{"html":"https://cve.report/CVE-2021-37207","api":"https://cve.report/api/cve/CVE-2021-37207.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-37207","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-37207"},"summary":{"title":"CVE-2021-37207","description":"A vulnerability has been identified in SENTRON powermanager V3 (All versions). The affected application assigns improper access rights to a specific folder containing configuration files. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges.","state":"PUBLIC","assigner":"productcert@siemens.com","published_at":"2021-11-09 12:15:00","updated_at":"2021-11-11 02:34:00"},"problem_types":["CWE-732"],"metrics":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-537983.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-537983.pdf","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-37207","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-37207","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"37207","vulnerable":"1","versionEndIncluding":"3.6","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"sentron_powermanager_3","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2021-37207","qid":"590612","title":"Siemens SENTRON powermanager Incorrect Permission Assignment for Critical Resource Vulnerability (ICSA-21-315-10)"}]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2021-37207","STATE":"PUBLIC"},"data_format":"MITRE","data_version":"4.0","data_type":"CVE","affects":{"vendor":{"vendor_data":[{"vendor_name":"Siemens","product":{"product_data":[{"product_name":"SENTRON powermanager V3","version":{"version_data":[{"version_value":"All versions"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-732: Incorrect Permission Assignment for Critical Resource"}]}]},"description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in SENTRON powermanager V3 (All versions). The affected application assigns improper access rights to a specific folder containing configuration files. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges."}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-537983.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-537983.pdf"}]}},"nvd":{"publishedDate":"2021-11-09 12:15:00","lastModifiedDate":"2021-11-11 02:34:00","problem_types":["CWE-732"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:C/I:C/A:C","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE","baseScore":7.2},"severity":"HIGH","exploitabilityScore":3.9,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:sentron_powermanager_3:*:*:*:*:*:*:*:*","versionStartIncluding":"3.0","versionEndIncluding":"3.6","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"37207","Ordinal":"212790","Title":"CVE-2021-37207","CVE":"CVE-2021-37207","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"37207","Ordinal":"1","NoteData":"A vulnerability has been identified in SENTRON powermanager V3 (All versions). The affected application assigns improper access rights to a specific folder containing configuration files. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"37207","Ordinal":"2","NoteData":"2021-11-09","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"37207","Ordinal":"3","NoteData":"2021-11-09","Type":"Other","Title":"Modified"}]}}}