{"api_version":"1","generated_at":"2026-07-25T00:16:19+00:00","cve":"CVE-2021-38394","urls":{"html":"https://cve.report/CVE-2021-38394","api":"https://cve.report/api/cve/CVE-2021-38394.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-38394","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-38394"},"summary":{"title":"CVE-2021-38394","description":"An attacker with physical access to the device can extract the binary that checks for the hardware key and reverse engineer it, which could be used to create a physical duplicate of a valid hardware key. The hardware key allows access to special settings when inserted.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2021-10-04 18:15:00","updated_at":"2021-10-13 19:48:00"},"problem_types":["CWE-1278"],"metrics":[],"references":[{"url":"https://us-cert.cisa.gov/ics/advisories/icsma-21-273-01","name":"https://us-cert.cisa.gov/ics/advisories/icsma-21-273-01","refsource":"MISC","tags":[],"title":"Boston Scientific Zoom Latitude | CISA","mime":"text/html","httpstatus":"200","archivestatus":"503"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-38394","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-38394","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"LEGACY","value":"Endres Puschner - Max Planck Institute for Security and Privacy, Bochum, Christoph Saatjohann - FH Münster  University of Applied Sciences, Christian Dresen - FH Münster University of Applied Sciences, and Markus  Willing - University of Muenster, discovered these issues as part of broader academic research of cardiac devices  and reported them to Boston Scientific.","lang":""}],"nvd_cpes":[{"cve_year":"2021","cve_id":"38394","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"bostonscientific","cpe5":"zoom_latitude_pogrammer\\/recorder\\/monitor_3120","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"38394","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"bostonscientific","cpe5":"zoom_latitude_pogrammer\\/recorder\\/monitor_3120_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","DATE_PUBLIC":"2021-09-30T21:02:00.000Z","ID":"CVE-2021-38394","STATE":"PUBLIC","TITLE":"Missing Protection against Hardware Reverse Engineering Using Integrated Circuit Imaging Techniques for Boston Scientific Zoom Latitude"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"ZOOM LATITUDE","version":{"version_data":[{"version_value":"Model 3120"}]}}]},"vendor_name":"Boston Scientific"}]}},"credit":[{"lang":"eng","value":"Endres Puschner - Max Planck Institute for Security and Privacy, Bochum, Christoph Saatjohann - FH Münster  University of Applied Sciences, Christian Dresen - FH Münster University of Applied Sciences, and Markus  Willing - University of Muenster, discovered these issues as part of broader academic research of cardiac devices  and reported them to Boston Scientific."}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An attacker with physical access to the device can extract the binary that checks for the hardware key and reverse engineer it, which could be used to create a physical duplicate of a valid hardware key. The hardware key allows access to special settings when inserted."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"HIGH","attackVector":"PHYSICAL","availabilityImpact":"LOW","baseScore":6.2,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:P/AC:H/PR:N/UI:R/S:C/C:L/I:H/A:L","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-1278 "}]}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://us-cert.cisa.gov/ics/advisories/icsma-21-273-01","name":"https://us-cert.cisa.gov/ics/advisories/icsma-21-273-01"}]},"source":{"advisory":"ICSMA-21-273-01","defect":["CWE-1278"],"discovery":"EXTERNAL"},"work_around":[{"lang":"eng","value":"Boston Scientific is in the process of transitioning all users to a replacement programmer with enhanced security,  the LATITUDE Programming System, Model 3300. Boston Scientific will not issue a product update to address the identified vulnerabilities in the ZOOM LATITUDE Programming System, Model 3120."}]},"nvd":{"publishedDate":"2021-10-04 18:15:00","lastModifiedDate":"2021-10-13 19:48:00","problem_types":["CWE-1278"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"PHYSICAL","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":6.4,"baseSeverity":"MEDIUM"},"exploitabilityScore":0.5,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:M/Au:N/C:C/I:C/A:C","accessVector":"LOCAL","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE","baseScore":6.9},"severity":"MEDIUM","exploitabilityScore":3.4,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:bostonscientific:zoom_latitude_pogrammer\\/recorder\\/monitor_3120_firmware:*:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:bostonscientific:zoom_latitude_pogrammer\\/recorder\\/monitor_3120:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"38394","Ordinal":"214056","Title":"CVE-2021-38394","CVE":"CVE-2021-38394","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"38394","Ordinal":"1","NoteData":"An attacker with physical access to the device can extract the binary that checks for the hardware key and reverse engineer it, which could be used to create a physical duplicate of a valid hardware key. The hardware key allows access to special settings when inserted.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"38394","Ordinal":"2","NoteData":"2021-10-04","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"38394","Ordinal":"3","NoteData":"2021-10-04","Type":"Other","Title":"Modified"}]}}}