{"api_version":"1","generated_at":"2026-07-23T13:04:06+00:00","cve":"CVE-2021-38401","urls":{"html":"https://cve.report/CVE-2021-38401","api":"https://cve.report/api/cve/CVE-2021-38401.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-38401","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-38401"},"summary":{"title":"CVE-2021-38401","description":"Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an untrusted pointer dereference, which may allow an attacker to execute arbitrary code and cause the application to crash.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2021-12-20 21:15:00","updated_at":"2021-12-27 20:16:00"},"problem_types":["CWE-822"],"metrics":[],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01","refsource":"MISC","tags":[],"title":"Fuji Electric Tellus Lite V-Simulator and V-Server Lite | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-38401","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-38401","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"LEGACY","value":"kimiya, working with Trend Micro’s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA.","lang":""}],"nvd_cpes":[{"cve_year":"2021","cve_id":"38401","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"fujielectric","cpe5":"v-server","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"lite","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"38401","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"fujielectric","cpe5":"v-simulator","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"lite","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2021-38401","qid":"590620","title":"Fuji Electric Tellus Lite V-Simulator and V-Server Lite Multiple Vulnerabilities (ICSA-21-299-01)"}]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2021-38401","STATE":"PUBLIC","TITLE":" Fuji Electric Tellus Lite V-Simulator untrusted pointer dereference"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"V-Server Lite","version":{"version_data":[{"version_affected":"<","version_value":"4.0.12.0"}]}},{"product_name":"Tellus Lite V-Simulator","version":{"version_data":[{"version_affected":"<","version_value":"4.0.12.0"}]}}]},"vendor_name":" Fuji Electric"}]}},"credit":[{"lang":"eng","value":"kimiya, working with Trend Micro’s Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA."}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an untrusted pointer dereference, which may allow an attacker to execute arbitrary code and cause the application to crash."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-822 - Untrusted pointer dereference"}]}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-21-299-01"}]},"solution":[{"lang":"eng","value":"Fuji Electric recommends updating software to the latest version:\nTELLUS Lite software: Version 4.0.12.0 Disk1\nTELLUS Lite software: Version 4.0.12.0 Disk2\nV-Server Lite software: Version 4.0.12.0 Disk1\nV-Server Lite software: Version 4.0.12.0 Disk2"}],"source":{"advisory":"ICSA-21-299-01","discovery":"EXTERNAL"}},"nvd":{"publishedDate":"2021-12-20 21:15:00","lastModifiedDate":"2021-12-27 20:16:00","problem_types":["CWE-822"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":6.8},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:fujielectric:v-server:*:*:*:*:lite:*:*:*","versionEndExcluding":"4.0.12.0","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:fujielectric:v-simulator:*:*:*:*:lite:*:*:*","versionEndExcluding":"4.0.12.0","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"38401","Ordinal":"214063","Title":"CVE-2021-38401","CVE":"CVE-2021-38401","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"38401","Ordinal":"1","NoteData":"Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an untrusted pointer dereference, which may allow an attacker to execute arbitrary code and cause the application to crash.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"38401","Ordinal":"2","NoteData":"2021-12-20","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"38401","Ordinal":"3","NoteData":"2021-12-20","Type":"Other","Title":"Modified"}]}}}