{"api_version":"1","generated_at":"2026-07-23T13:02:15+00:00","cve":"CVE-2021-38418","urls":{"html":"https://cve.report/CVE-2021-38418","api":"https://cve.report/api/cve/CVE-2021-38418.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-38418","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-38418"},"summary":{"title":"CVE-2021-38418","description":"Delta Electronics DIALink versions 1.2.4.0 and prior runs by default on HTTP, which may allow an attacker to be positioned between the traffic and perform a machine-in-the-middle attack to access information without authorization.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2021-11-03 20:15:00","updated_at":"2021-11-05 14:58:00"},"problem_types":["CWE-319"],"metrics":[],"references":[{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02","name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02","refsource":"MISC","tags":[],"title":"Delta Electronics DIALink | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-38418","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-38418","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"LEGACY","value":"Michael Heinzl reported these vulnerabilities to CISA.","lang":""}],"nvd_cpes":[{"cve_year":"2021","cve_id":"38418","vulnerable":"1","versionEndIncluding":"1.2.4.0","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"deltaww","cpe5":"dialink","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2021-38418","qid":"591006","title":"Delta Electronics DIALink Multiple Vulnerabilities (ICSA-21-294-02)"}]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","DATE_PUBLIC":"2021-10-21T18:29:00.000Z","ID":"CVE-2021-38418","STATE":"PUBLIC","TITLE":"Delta Electronics DIALink"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"DIALink","version":{"version_data":[{"version_affected":"<=","version_name":"All","version_value":"1.2.4.0"}]}}]},"vendor_name":"Delta Electronics"}]}},"credit":[{"lang":"eng","value":"Michael Heinzl reported these vulnerabilities to CISA."}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Delta Electronics DIALink versions 1.2.4.0 and prior runs by default on HTTP, which may allow an attacker to be positioned between the traffic and perform a machine-in-the-middle attack to access information without authorization."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-319 Cleartext Transmission of Sensitive Information"}]}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02","name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"}]},"source":{"advisory":"ICSA-21-294-02","discovery":"UNKNOWN"},"work_around":[{"lang":"eng","value":"Delta Electronics is aware of the vulnerabilities and is currently working on an update. "}]},"nvd":{"publishedDate":"2021-11-03 20:15:00","lastModifiedDate":"2021-11-05 14:58:00","problem_types":["CWE-319"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":5.9,"baseSeverity":"MEDIUM"},"exploitabilityScore":2.2,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:N/A:N","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":4.3},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:deltaww:dialink:*:*:*:*:*:*:*:*","versionEndIncluding":"1.2.4.0","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"38418","Ordinal":"214080","Title":"CVE-2021-38418","CVE":"CVE-2021-38418","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"38418","Ordinal":"1","NoteData":"Delta Electronics DIALink versions 1.2.4.0 and prior runs by default on HTTP, which may allow an attacker to be positioned between the traffic and perform a machine-in-the-middle attack to access information without authorization.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"38418","Ordinal":"2","NoteData":"2021-11-03","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"38418","Ordinal":"3","NoteData":"2021-11-03","Type":"Other","Title":"Modified"}]}}}