{"api_version":"1","generated_at":"2026-07-23T12:17:40+00:00","cve":"CVE-2021-38422","urls":{"html":"https://cve.report/CVE-2021-38422","api":"https://cve.report/api/cve/CVE-2021-38422.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-38422","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-38422"},"summary":{"title":"CVE-2021-38422","description":"Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2021-11-03 20:15:00","updated_at":"2021-11-05 15:09:00"},"problem_types":["CWE-312"],"metrics":[],"references":[{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02","name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02","refsource":"MISC","tags":[],"title":"Delta Electronics DIALink | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-38422","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-38422","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"LEGACY","value":"Michael Heinzl reported these vulnerabilities to CISA.","lang":""}],"nvd_cpes":[{"cve_year":"2021","cve_id":"38422","vulnerable":"1","versionEndIncluding":"1.2.4.0","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"deltaww","cpe5":"dialink","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2021-38422","qid":"591006","title":"Delta Electronics DIALink Multiple Vulnerabilities (ICSA-21-294-02)"}]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","DATE_PUBLIC":"2021-10-21T18:29:00.000Z","ID":"CVE-2021-38422","STATE":"PUBLIC","TITLE":"Delta Electronics DIALink"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"DIALink","version":{"version_data":[{"version_affected":"<=","version_name":"All","version_value":"1.2.4.0"}]}}]},"vendor_name":"Delta Electronics"}]}},"credit":[{"lang":"eng","value":"Michael Heinzl reported these vulnerabilities to CISA."}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-312 Cleartext Storage of Sensitive Information"}]}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02","name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"}]},"source":{"advisory":"ICSA-21-294-02","discovery":"UNKNOWN"},"work_around":[{"lang":"eng","value":"Delta Electronics is aware of the vulnerabilities and is currently working on an update. "}]},"nvd":{"publishedDate":"2021-11-03 20:15:00","lastModifiedDate":"2021-11-05 15:09:00","problem_types":["CWE-312"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:P/A:P","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":4.6},"severity":"MEDIUM","exploitabilityScore":3.9,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:deltaww:dialink:*:*:*:*:*:*:*:*","versionEndIncluding":"1.2.4.0","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"38422","Ordinal":"214084","Title":"CVE-2021-38422","CVE":"CVE-2021-38422","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"38422","Ordinal":"1","NoteData":"Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"38422","Ordinal":"2","NoteData":"2021-11-03","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"38422","Ordinal":"3","NoteData":"2021-11-03","Type":"Other","Title":"Modified"}]}}}