{"api_version":"1","generated_at":"2026-04-23T13:26:27+00:00","cve":"CVE-2021-40335","urls":{"html":"https://cve.report/CVE-2021-40335","api":"https://cve.report/api/cve/CVE-2021-40335.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-40335","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-40335"},"summary":{"title":"CVE-2021-40335","description":"A vulnerability exists in the HTTP web interface where the web interface does not sufficiently verify if a well-formed, valid, consistent request was intentionally provided by the user who submitted the request. This cause a Cross Site Request Forgery (CSRF), which if exploited could lead an attacker to gain unauthorized access to the web application and perform an unwanted operation on it without the knowledge of the legitimate user. An attacker, who successfully makes an MSM user who has already established a session to MSM web interface clicks a forged link to the MSM web interface, e.g., link is sent per E-Mail, could perform harmful command on MSM through its web server interface. This issue affects: Hitachi Energy MSM V2.2 and prior versions.","state":"PUBLIC","assigner":"cybersecurity@hitachienergy.com","published_at":"2022-07-25 15:15:00","updated_at":"2023-04-19 15:32:00"},"problem_types":["CWE-352"],"metrics":[],"references":[{"url":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000085&LanguageCode=en&DocumentPartId=&Action=Launch","name":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000085&LanguageCode=en&DocumentPartId=&Action=Launch","refsource":"CONFIRM","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-40335","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-40335","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"40335","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"abb","cpe5":"modular_switchgear_monitoring","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40335","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"abb","cpe5":"modular_switchgear_monitoring_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40335","vulnerable":"1","versionEndIncluding":"2.2.0","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"abb","cpe5":"modular_switchgear_monitoring_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40335","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hitachienergy","cpe5":"modular_switchgear_monitoring","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40335","vulnerable":"1","versionEndIncluding":"2.2.0","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachienergy","cpe5":"modular_switchgear_monitoring_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@hitachienergy.com","DATE_PUBLIC":"2022-07-12T14:30:00.000Z","ID":"CVE-2021-40335","STATE":"PUBLIC","TITLE":"Cross Site Request Forgery (CSRF) in Hitachi Energy’s MSM Product"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"MSM","version":{"version_data":[{"version_affected":"<=","version_name":"v2.2","version_value":"V2.2"}]}}]},"vendor_name":"Hitachi Energy"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability exists in the HTTP web interface where the web interface does not sufficiently verify if a well-formed, valid, consistent request was intentionally provided by the user who submitted the request. This cause a Cross Site Request Forgery (CSRF), which if exploited could lead an attacker to gain unauthorized access to the web application and perform an unwanted operation on it without the knowledge of the legitimate user. An attacker, who successfully makes an MSM user who has already established a session to MSM web interface clicks a forged link to the MSM web interface, e.g., link is sent per E-Mail, could perform harmful command on MSM through its web server interface. This issue affects: Hitachi Energy MSM V2.2 and prior versions."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":5,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:L","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-352 Cross-Site Request Forgery (CSRF)"}]}]},"references":{"reference_data":[{"name":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000085&LanguageCode=en&DocumentPartId=&Action=Launch","refsource":"CONFIRM","url":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000085&LanguageCode=en&DocumentPartId=&Action=Launch"}]},"source":{"discovery":"INTERNAL"},"work_around":[{"lang":"eng","value":"Apply mitigation strategy as described in Mitigation Factors Section in the advisory. "}]},"nvd":{"publishedDate":"2022-07-25 15:15:00","lastModifiedDate":"2023-04-19 15:32:00","problem_types":["CWE-352"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:hitachienergy:modular_switchgear_monitoring_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.2.0","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:hitachienergy:modular_switchgear_monitoring:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"40335","Ordinal":"216064","Title":"CVE-2021-40335","CVE":"CVE-2021-40335","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"40335","Ordinal":"1","NoteData":"** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided.","Type":"Description","Title":null}]}}}