{"api_version":"1","generated_at":"2026-04-22T22:49:54+00:00","cve":"CVE-2021-40358","urls":{"html":"https://cve.report/CVE-2021-40358","api":"https://cve.report/api/cve/CVE-2021-40358.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-40358","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-40358"},"summary":{"title":"CVE-2021-40358","description":"A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files.","state":"PUBLIC","assigner":"productcert@siemens.com","published_at":"2021-11-09 12:15:00","updated_at":"2023-04-11 10:15:00"},"problem_types":["CWE-22"],"metrics":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-40358","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-40358","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_pcs_7","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_pcs_7","cpe6":"8.2","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_pcs_7","cpe6":"9.0","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_pcs_7","cpe6":"9.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_pcs_7","cpe6":"9.1","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"8.2","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_pcs_7","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"15","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"15.1","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"15.1","cpe7":"update_1","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"15.1","cpe7":"update_2","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"15.1","cpe7":"update_3","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"15.1","cpe7":"update_4","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"15.1","cpe7":"update_5","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"15.1","cpe7":"update_6","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"16","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"16","cpe7":"update1","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"16","cpe7":"update2","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"16","cpe7":"update3","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"16","cpe7":"update4","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"17","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"17","cpe7":"update1","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"sp1","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"sp1_update1","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"sp1_update10","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"sp1_update11","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"sp1_update12","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"sp1_update13","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"sp1_update14","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"sp1_update15","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"sp1_update16","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"sp1_update17","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"sp1_update18","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"sp1_update2","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"sp1_update3","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"sp1_update4","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"sp1_update5","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"sp1_update6","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"sp1_update7","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"sp1_update8","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"sp1_update9","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"update_1","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.5","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.5","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.5","cpe7":"sp1","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.5","cpe7":"sp1_update1","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.5","cpe7":"sp1_update2","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.5","cpe7":"sp2","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.5","cpe7":"sp2_update1","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.5","cpe7":"sp2_update2","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.5","cpe7":"sp2_update3","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.5","cpe7":"sp2_update4","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"40358","vulnerable":"1","versionEndIncluding":"7.4","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2021-40358","qid":"590822","title":"Siemens SIMATIC WinCC (Update B) Multiple Vulnerabilities (ICSA-21-315-03)"}]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2021-40358","ASSIGNER":"productcert@siemens.com","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')","cweId":"CWE-22"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Siemens","product":{"product_data":[{"product_name":"SIMATIC PCS 7 V8.2","version":{"version_data":[{"version_affected":"=","version_value":"All versions"}]}},{"product_name":"SIMATIC PCS 7 V9.0","version":{"version_data":[{"version_affected":"=","version_value":"All versions < V9.0 SP3 UC04"}]}},{"product_name":"SIMATIC PCS 7 V9.1","version":{"version_data":[{"version_affected":"=","version_value":"All versions < V9.1 SP1"}]}},{"product_name":"SIMATIC WinCC V15 and earlier","version":{"version_data":[{"version_affected":"=","version_value":"All versions < V15 SP1 Update 7"}]}},{"product_name":"SIMATIC WinCC V16","version":{"version_data":[{"version_affected":"=","version_value":"All versions < V16 Update 5"}]}},{"product_name":"SIMATIC WinCC V17","version":{"version_data":[{"version_affected":"=","version_value":"All versions < V17 Update 2"}]}},{"product_name":"SIMATIC WinCC V7.4","version":{"version_data":[{"version_affected":"=","version_value":"All versions < V7.4 SP1 Update 19"}]}},{"product_name":"SIMATIC WinCC V7.5","version":{"version_data":[{"version_affected":"=","version_value":"All versions < V7.5 SP2 Update 5"}]}}]}}]}},"references":{"reference_data":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf","refsource":"MISC","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"}]},"impact":{"cvss":[{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C","baseScore":9.9,"baseSeverity":"CRITICAL"}]}},"nvd":{"publishedDate":"2021-11-09 12:15:00","lastModifiedDate":"2023-04-11 10:15:00","problem_types":["CWE-22"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":9.9,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.1,"impactScore":6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":7.5},"severity":"HIGH","exploitabilityScore":10,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_pcs_7:8.2:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.4:sp1:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.4:-:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.4:update_1:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update1:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update2:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update1:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update2:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update3:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update4:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update5:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update6:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update7:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update8:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update9:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update10:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update11:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update12:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update13:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:15.1:-:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:15.1:update_1:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:15.1:update_2:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:15.1:update_3:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:15.1:update_4:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_pcs_7:9.0:-:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.5:sp2:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update1:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update2:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update3:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update4:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:17:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:15:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:17:update1:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:16:update1:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:16:update2:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:16:update3:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:16:update4:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_pcs_7:9.1:-:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:15.1:update_6:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:15.1:update_5:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update14:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update15:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update16:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update17:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update18:*:*:*:*:*:*","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"40358","Ordinal":"216097","Title":"CVE-2021-40358","CVE":"CVE-2021-40358","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"40358","Ordinal":"1","NoteData":"A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 and earlier (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). Legitimate file operations of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"40358","Ordinal":"2","NoteData":"2021-11-09","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"40358","Ordinal":"3","NoteData":"2022-02-09","Type":"Other","Title":"Modified"}]}}}