{"api_version":"1","generated_at":"2026-04-22T19:59:41+00:00","cve":"CVE-2021-43548","urls":{"html":"https://cve.report/CVE-2021-43548","api":"https://cve.report/api/cve/CVE-2021-43548.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-43548","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-43548"},"summary":{"title":"CVE-2021-43548","description":"Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2021-12-27 19:15:00","updated_at":"2022-01-12 13:30:00"},"problem_types":["CWE-20"],"metrics":[],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsma-21-322-02","name":"https://www.cisa.gov/uscert/ics/advisories/icsma-21-322-02","refsource":"MISC","tags":[],"title":"Philips Patient Information Center iX (PIC iX) and Efficia CM Series | CISA","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-43548","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-43548","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"LEGACY","value":"Younes Dragoni, Andrea Palanca and Ivan Speziale of Nozomi Networks","lang":""}],"nvd_cpes":[{"cve_year":"2021","cve_id":"43548","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"philips","cpe5":"patient_information_center_ix","cpe6":"c.02","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"43548","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"philips","cpe5":"patient_information_center_ix","cpe6":"c.03","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","DATE_PUBLIC":"2021-11-18T15:34:00.000Z","ID":"CVE-2021-43548","STATE":"PUBLIC","TITLE":"Philips Patient Information Center iX (PIC iX) and Efficia CM Series Improper Input Validation"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Patient Information Center iX (PIC iX)","version":{"version_data":[{"version_affected":"=","version_value":"C.02"},{"version_affected":"=","version_value":"C.03"}]}}]},"vendor_name":"Philips"}]}},"credit":[{"lang":"eng","value":"Younes Dragoni, Andrea Palanca and Ivan Speziale of Nozomi Networks"}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"HIGH","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-20 Improper Input Validation"}]}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://www.cisa.gov/uscert/ics/advisories/icsma-21-322-02","name":"https://www.cisa.gov/uscert/ics/advisories/icsma-21-322-02"}]},"solution":[{"lang":"eng"}],"source":{"advisory":"ICSMA-21-322-02","discovery":"UNKNOWN"}},"nvd":{"publishedDate":"2021-12-27 19:15:00","lastModifiedDate":"2022-01-12 13:30:00","problem_types":["CWE-20"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"HIGH","availabilityImpact":"NONE","baseScore":6.5,"baseSeverity":"MEDIUM"},"exploitabilityScore":2.8,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:A/AC:L/Au:N/C:N/I:P/A:N","accessVector":"ADJACENT_NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE","baseScore":3.3},"severity":"LOW","exploitabilityScore":6.5,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:philips:patient_information_center_ix:c.02:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:philips:patient_information_center_ix:c.03:*:*:*:*:*:*:*","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"43548","Ordinal":"220615","Title":"CVE-2021-43548","CVE":"CVE-2021-43548","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"43548","Ordinal":"1","NoteData":"** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided.","Type":"Description","Title":null}]}}}