{"api_version":"1","generated_at":"2026-07-23T13:49:28+00:00","cve":"CVE-2021-43937","urls":{"html":"https://cve.report/CVE-2021-43937","api":"https://cve.report/api/cve/CVE-2021-43937.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-43937","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-43937"},"summary":{"title":"CVE-2021-43937","description":"Elcomplus SmartPTT SCADA Server web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2022-04-29 16:15:00","updated_at":"2022-05-11 14:33:00"},"problem_types":["CWE-352"],"metrics":[],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05","refsource":"CONFIRM","tags":[],"title":"Elcomplus SmartPPT SCADA Server | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-43937","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-43937","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"LEGACY","value":"Michael Heinzl reported these vulnerabilities to CISA.","lang":""}],"nvd_cpes":[{"cve_year":"2021","cve_id":"43937","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"smartptt","cpe5":"scada_server","cpe6":"1.4","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2021-43937","STATE":"PUBLIC","TITLE":"Elcomplus SmartPTT SCADA Server Cross-site Request Forgery"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"SmartPTT SCADA Server","version":{"version_data":[{"version_affected":"=","version_value":"1.4"}]}}]},"vendor_name":"Elcomplus"}]}},"credit":[{"lang":"eng","value":"Michael Heinzl reported these vulnerabilities to CISA."}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Elcomplus SmartPTT SCADA Server web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":7.6,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"LOW","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-200 Information Exposure"}]}]},"references":{"reference_data":[{"name":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05","refsource":"CONFIRM","url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05"}]},"solution":[{"lang":"eng","value":"Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."}],"source":{"advisory":"ICSA-22-109-05","discovery":"UNKNOWN"}},"nvd":{"publishedDate":"2022-04-29 16:15:00","lastModifiedDate":"2022-05-11 14:33:00","problem_types":["CWE-352"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":6.8},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:smartptt:scada_server:1.4:*:*:*:*:*:*:*","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"43937","Ordinal":"221556","Title":"CVE-2021-43937","CVE":"CVE-2021-43937","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"43937","Ordinal":"1","NoteData":"** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided.","Type":"Description","Title":null}]}}}