{"api_version":"1","generated_at":"2026-07-23T22:22:54+00:00","cve":"CVE-2021-44165","urls":{"html":"https://cve.report/CVE-2021-44165","api":"https://cve.report/api/cve/CVE-2021-44165.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-44165","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-44165"},"summary":{"title":"CVE-2021-44165","description":"A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41). The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution.","state":"PUBLIC","assigner":"productcert@siemens.com","published_at":"2021-12-14 12:15:00","updated_at":"2021-12-16 22:00:00"},"problem_types":["CWE-121"],"metrics":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf","name":"N/A","refsource":"CONFIRM","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-44165","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-44165","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"44165","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"7kg9501-0aa01-0aa1","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"44165","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"7kg9501-0aa01-0aa1_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"44165","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"7kg9501-0aa01-2aa1","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"44165","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"7kg9501-0aa01-2aa1_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"44165","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"7kg9501-0aa31-0aa1","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"44165","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"7kg9501-0aa31-0aa1_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"44165","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"7kg9501-0aa31-2aa1","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"44165","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"7kg9501-0aa31-2aa1_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2021-44165","qid":"590714","title":"Siemens POWER METER SICAM Q100 Vulnerability (ICSA-21-350-07)"}]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2021-44165","STATE":"PUBLIC"},"data_format":"MITRE","data_version":"4.0","data_type":"CVE","affects":{"vendor":{"vendor_data":[{"vendor_name":"Siemens","product":{"product_data":[{"product_name":"POWER METER SICAM Q100","version":{"version_data":[{"version_value":"All versions < V2.41"}]}},{"product_name":"POWER METER SICAM Q100","version":{"version_data":[{"version_value":"All versions < V2.41"}]}},{"product_name":"POWER METER SICAM Q100","version":{"version_data":[{"version_value":"All versions < V2.41"}]}},{"product_name":"POWER METER SICAM Q100","version":{"version_data":[{"version_value":"All versions < V2.41"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-121: Stack-based Buffer Overflow"}]}]},"description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41). The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution."}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf"}]}},"nvd":{"publishedDate":"2021-12-14 12:15:00","lastModifiedDate":"2021-12-16 22:00:00","problem_types":["CWE-121"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.2,"baseSeverity":"HIGH"},"exploitabilityScore":1.2,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE","baseScore":9},"severity":"HIGH","exploitabilityScore":8,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:7kg9501-0aa01-2aa1_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.41","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:7kg9501-0aa01-2aa1:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:7kg9501-0aa31-0aa1_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.41","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:7kg9501-0aa31-0aa1:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:7kg9501-0aa31-2aa1_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.41","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:7kg9501-0aa31-2aa1:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:7kg9501-0aa01-0aa1_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.41","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:7kg9501-0aa01-0aa1:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"44165","Ordinal":"221827","Title":"CVE-2021-44165","CVE":"CVE-2021-44165","Year":"2021"},"notes":[]}}}