{"api_version":"1","generated_at":"2026-07-23T11:55:58+00:00","cve":"CVE-2021-46153","urls":{"html":"https://cve.report/CVE-2021-46153","api":"https://cve.report/api/cve/CVE-2021-46153.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-46153","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-46153"},"summary":{"title":"CVE-2021-46153","description":"A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a memory corruption vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14645, ZDI-CAN-15305, ZDI-CAN-15589, ZDI-CAN-15599)","state":"PUBLIC","assigner":"productcert@siemens.com","published_at":"2022-02-09 16:15:00","updated_at":"2023-06-26 18:55:00"},"problem_types":["CWE-787"],"metrics":[],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-299/","name":"https://www.zerodayinitiative.com/advisories/ZDI-22-299/","refsource":"MISC","tags":[],"title":"ZDI-22-299 | Zero Day Initiative","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-298/","name":"https://www.zerodayinitiative.com/advisories/ZDI-22-298/","refsource":"MISC","tags":[],"title":"ZDI-22-298 | Zero Day Initiative","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-300/","name":"https://www.zerodayinitiative.com/advisories/ZDI-22-300/","refsource":"MISC","tags":[],"title":"ZDI-22-300 | Zero Day Initiative","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-609880.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-609880.pdf","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"200"},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-297/","name":"https://www.zerodayinitiative.com/advisories/ZDI-22-297/","refsource":"MISC","tags":[],"title":"ZDI-22-297 | Zero Day Initiative","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-46153","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-46153","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"46153","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simcenter_femap","cpe6":"2020.2","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"46153","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simcenter_femap","cpe6":"2020.2","cpe7":"maintenance_pack1","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"46153","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simcenter_femap","cpe6":"2020.2","cpe7":"maintenance_pack2","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"46153","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simcenter_femap","cpe6":"2020.2","cpe7":"maintenance_pack3","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"46153","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simcenter_femap","cpe6":"2021.1","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"46153","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simcenter_femap","cpe6":"2021.1","cpe7":"maintenance_pack1","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"46153","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simcenter_femap","cpe6":"2021.1","cpe7":"maintenance_pack2","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"46153","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simcenter_femap","cpe6":"2021.1","cpe7":"maintenance_pack3","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2021-46153","STATE":"PUBLIC"},"data_format":"MITRE","data_version":"4.0","data_type":"CVE","affects":{"vendor":{"vendor_data":[{"vendor_name":"Siemens","product":{"product_data":[{"product_name":"Simcenter Femap V2020.2","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"Simcenter Femap V2021.1","version":{"version_data":[{"version_value":"All versions"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer"}]}]},"description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a memory corruption vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14645, ZDI-CAN-15305, ZDI-CAN-15589, ZDI-CAN-15599)"}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-609880.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-609880.pdf"},{"refsource":"MISC","name":"https://www.zerodayinitiative.com/advisories/ZDI-22-299/","url":"https://www.zerodayinitiative.com/advisories/ZDI-22-299/"},{"refsource":"MISC","name":"https://www.zerodayinitiative.com/advisories/ZDI-22-300/","url":"https://www.zerodayinitiative.com/advisories/ZDI-22-300/"},{"refsource":"MISC","name":"https://www.zerodayinitiative.com/advisories/ZDI-22-297/","url":"https://www.zerodayinitiative.com/advisories/ZDI-22-297/"},{"refsource":"MISC","name":"https://www.zerodayinitiative.com/advisories/ZDI-22-298/","url":"https://www.zerodayinitiative.com/advisories/ZDI-22-298/"}]}},"nvd":{"publishedDate":"2022-02-09 16:15:00","lastModifiedDate":"2023-06-26 18:55:00","problem_types":["CWE-787"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":6.8},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simcenter_femap:2020.2:maintenance_pack1:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simcenter_femap:2020.2:maintenance_pack2:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simcenter_femap:2021.1:maintenance_pack1:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simcenter_femap:2021.1:maintenance_pack2:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simcenter_femap:2020.2:-:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simcenter_femap:2021.1:-:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simcenter_femap:2020.2:maintenance_pack3:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simcenter_femap:2021.1:maintenance_pack3:*:*:*:*:*:*","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"46153","Ordinal":"225205","Title":"CVE-2021-46153","CVE":"CVE-2021-46153","Year":"2021"},"notes":[]}}}