{"api_version":"1","generated_at":"2026-07-23T23:41:46+00:00","cve":"CVE-2022-0354","urls":{"html":"https://cve.report/CVE-2022-0354","api":"https://cve.report/api/cve/CVE-2022-0354.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-0354","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-0354"},"summary":{"title":"CVE-2022-0354","description":"A vulnerability was reported in Lenovo System Update that could allow a local user with interactive system access the ability to execute code with elevated privileges only during the installation of a System Update package released before 2022-02-25 that displays a command prompt window.","state":"PUBLISHED","assigner":"lenovo","published_at":"2022-04-22 21:15:10","updated_at":"2026-06-02 14:16:26"},"problem_types":["NVD-CWE-noinfo","CWE-317","Insecure GUI","CWE-317 CWE-317 Cleartext Storage of Sensitive Information in GUI"],"metrics":[{"version":"3.1","source":"nvd@nist.gov","type":"Primary","score":"7.8","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"psirt@lenovo.com","type":"Secondary","score":"7.3","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","baseScore":7.3,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"DECLARED","score":"7.3","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","data":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.3,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","version":"3.1"}},{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"7.2","severity":"","vector":"AV:L/AC:L/Au:N/C:C/I:C/A:C","data":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:C/I:C/A:C","baseScore":7.2,"accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"}}],"references":[{"url":"https://support.lenovo.com/us/en/product_security/LEN-76673","name":"https://support.lenovo.com/us/en/product_security/LEN-76673","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"title":"Lenovo System Update Privilege Escalation Vulnerability - Lenovo Support US","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.infosec.tirol/cve-2022-0354/","name":"https://www.infosec.tirol/cve-2022-0354/","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory"],"title":"CVE-2022-0354: Local Privilege Escalation - infosec.tirol","mime":"text/html","httpstatus":"200","archivestatus":"403"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-0354","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-0354","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Lenovo","product":"System Update","version":"affected various","platforms":[]}],"timeline":[],"solutions":[{"source":"CNA","title":"","value":"Follow Mitigation Strategy in LEN-76673.","time":"","lang":"en"}],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Lenovo thanks Daniel Feichter (@VirtualAllocEx) at Infosec Tirol for reporting this issue.","lang":"en"}],"nvd_cpes":[{"cve_year":"2022","cve_id":"354","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"lenovo","cpe5":"system_update","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2022","cve_id":"354","cve":"CVE-2022-0354","epss":"0.000240000","percentile":"0.072030000","score_date":"2026-06-07","updated_at":"2026-06-08 00:14:16"},"legacy_qids":[{"cve":"CVE-2022-0354","qid":"376718","title":"Lenovo System Update Privilege Escalation Vulnerability (len-76673)"}]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-02T23:25:40.291Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://support.lenovo.com/us/en/product_security/LEN-76673"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.infosec.tirol/cve-2022-0354/"}],"title":"CVE Program Container"},{"metrics":[{"other":{"content":{"id":"CVE-2022-0354","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-06-02T13:48:54.060069Z","version":"2.0.3"},"type":"ssvc"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-317","description":"CWE-317 Cleartext Storage of Sensitive Information in GUI","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-06-02T13:50:02.923Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"product":"System Update","vendor":"Lenovo","versions":[{"status":"affected","version":"various"}]}],"credits":[{"lang":"en","value":"Lenovo thanks Daniel Feichter (@VirtualAllocEx) at Infosec Tirol for reporting this issue."}],"descriptions":[{"lang":"en","value":"A vulnerability was reported in Lenovo System Update that could allow a local user with interactive system access the ability to execute code with elevated privileges only during the installation of a System Update package released before 2022-02-25 that displays a command prompt window."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.3,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","version":"3.1"}}],"problemTypes":[{"descriptions":[{"description":"Insecure GUI","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2022-04-26T22:24:43.000Z","orgId":"da227ddf-6e25-4b41-b023-0f976dcaca4b","shortName":"lenovo"},"references":[{"tags":["x_refsource_MISC"],"url":"https://support.lenovo.com/us/en/product_security/LEN-76673"},{"tags":["x_refsource_MISC"],"url":"https://www.infosec.tirol/cve-2022-0354/"}],"solutions":[{"lang":"en","value":"Follow Mitigation Strategy in LEN-76673."}],"source":{"advisory":"LEN-76673","discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"psirt@lenovo.com","ID":"CVE-2022-0354","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"System Update","version":{"version_data":[{"version_affected":"=","version_value":"various"}]}}]},"vendor_name":"Lenovo"}]}},"credit":[{"lang":"eng","value":"Lenovo thanks Daniel Feichter (@VirtualAllocEx) at Infosec Tirol for reporting this issue."}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability was reported in Lenovo System Update that could allow a local user with interactive system access the ability to execute code with elevated privileges only during the installation of a System Update package released before 2022-02-25 that displays a command prompt window."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.3,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Insecure GUI"}]}]},"references":{"reference_data":[{"name":"https://support.lenovo.com/us/en/product_security/LEN-76673","refsource":"MISC","url":"https://support.lenovo.com/us/en/product_security/LEN-76673"},{"name":"https://www.infosec.tirol/cve-2022-0354/","refsource":"MISC","url":"https://www.infosec.tirol/cve-2022-0354/"}]},"solution":[{"lang":"en","value":"Follow Mitigation Strategy in LEN-76673."}],"source":{"advisory":"LEN-76673","discovery":"UNKNOWN"}}}},"cveMetadata":{"assignerOrgId":"da227ddf-6e25-4b41-b023-0f976dcaca4b","assignerShortName":"lenovo","cveId":"CVE-2022-0354","datePublished":"2022-04-22T20:30:47.000Z","dateReserved":"2022-01-24T00:00:00.000Z","dateUpdated":"2026-06-02T13:50:02.923Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2022-04-22 21:15:10","lastModifiedDate":"2026-06-02 14:16:26","problem_types":["NVD-CWE-noinfo","CWE-317","Insecure GUI","CWE-317 CWE-317 Cleartext Storage of Sensitive Information in GUI"],"metrics":{"cvssMetricV31":[{"source":"psirt@lenovo.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","baseScore":7.3,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.3,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:C/I:C/A:C","baseScore":7.2,"accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":3.9,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:lenovo:system_update:*:*:*:*:*:*:*:*","versionEndExcluding":"2022-02-25","matchCriteriaId":"3BD6ED86-7797-4773-BC46-6A7190811322"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2022","CveId":"354","Ordinal":"1","Title":"CVE-2022-0354","CVE":"CVE-2022-0354","Year":"2022"},"notes":[{"CveYear":"2022","CveId":"354","Ordinal":"1","NoteData":"A vulnerability was reported in Lenovo System Update that could allow a local user with interactive system access the ability to execute code with elevated privileges only during the installation of a System Update package released before 2022-02-25 that displays a command prompt window.","Type":"Description","Title":"CVE-2022-0354"}]}}}