{"api_version":"1","generated_at":"2026-05-13T13:01:07+00:00","cve":"CVE-2022-21939","urls":{"html":"https://cve.report/CVE-2022-21939","api":"https://cve.report/api/cve/CVE-2022-21939.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-21939","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-21939"},"summary":{"title":"CVE-2022-21939","description":"Sensitive Cookie Without 'HttpOnly' Flag vulnerability in Johnson Controls System Configuration Tool (SCT) version 14 prior to 14.2.3 and version 15 prior to 15.0.3 could allow access to the cookie.","state":"PUBLIC","assigner":"productsecurity@jci.com","published_at":"2023-02-09 21:15:00","updated_at":"2023-06-27 18:19:00"},"problem_types":["CWE-732"],"metrics":[],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-23-040-03","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-23-040-03","refsource":"MISC","tags":[],"title":"Johnson Controls System Configuration Tool (SCT) | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.johnsoncontrols.com/cyber-solutions/security-advisories","name":"https://www.johnsoncontrols.com/cyber-solutions/security-advisories","refsource":"MISC","tags":[],"title":"Product Security Advisories","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-21939","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-21939","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2022","cve_id":"21939","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"johnsoncontrols","cpe5":"metasys_system_configuration_tool","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2022-21939","ASSIGNER":"productsecurity@jci.com","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"Sensitive Cookie Without 'HttpOnly' Flag vulnerability in Johnson Controls System Configuration Tool (SCT) version 14 prior to 14.2.3 and version 15 prior to 15.0.3 could allow access to the cookie."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-1004: Sensitive Cookie Without 'HttpOnly' Flag","cweId":"CWE-1004"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Johnson Controls","product":{"product_data":[{"product_name":"System Configuration Tool (SCT)","version":{"version_data":[{"version_value":"14","version_affected":"="},{"version_value":"15","version_affected":"="}]}}]}}]}},"references":{"reference_data":[{"url":"https://www.johnsoncontrols.com/cyber-solutions/security-advisories","refsource":"MISC","name":"https://www.johnsoncontrols.com/cyber-solutions/security-advisories"},{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-23-040-03","refsource":"MISC","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-23-040-03"}]},"generator":{"engine":"Vulnogram 0.1.0-dev"},"source":{"discovery":"UNKNOWN"},"solution":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Update SCT version 14 with patch 14.2.3"}],"value":"Update SCT version 14 with patch 14.2.3"},{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Update SCT version 15 with patch 15.0.3<br>"}],"value":"Update SCT version 15 with patch 15.0.3\n"},{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Contact your local Johnson Controls office or Authorized Building Control Specialists (ABCS)."}],"value":"Contact your local Johnson Controls office or Authorized Building Control Specialists (ABCS)."}],"impact":{"cvss":[{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"}]}},"nvd":{"publishedDate":"2023-02-09 21:15:00","lastModifiedDate":"2023-06-27 18:19:00","problem_types":["CWE-732"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE","baseScore":6.1,"baseSeverity":"MEDIUM"},"exploitabilityScore":2.8,"impactScore":2.7}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:johnsoncontrols:metasys_system_configuration_tool:*:*:*:*:*:*:*:*","versionStartIncluding":"15.0","versionEndExcluding":"15.0.3","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:johnsoncontrols:metasys_system_configuration_tool:*:*:*:*:*:*:*:*","versionStartIncluding":"14.0","versionEndExcluding":"14.2.3","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2022","CveId":"21939","Ordinal":"223074","Title":"CVE-2022-21939","CVE":"CVE-2022-21939","Year":"2022"},"notes":[{"CveYear":"2022","CveId":"21939","Ordinal":"1","NoteData":"** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided.","Type":"Description","Title":null}]}}}