{"api_version":"1","generated_at":"2026-04-22T23:31:34+00:00","cve":"CVE-2022-22727","urls":{"html":"https://cve.report/CVE-2022-22727","api":"https://cve.report/api/cve/CVE-2022-22727.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-22727","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-22727"},"summary":{"title":"CVE-2022-22727","description":"A CWE-20: Improper Input Validation vulnerability exists that could allow an unauthenticated attacker to view data, change settings, impact availability of the software, or potentially impact a user�s local machine when the user clicks a specially crafted link. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2022-02-04 23:15:00","updated_at":"2023-11-07 03:43:00"},"problem_types":["CWE-20"],"metrics":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-07","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-07","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-22727","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-22727","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2022","cve_id":"22727","vulnerable":"1","versionEndIncluding":"2020","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"ecostruxure_power_monitoring_expert","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2022-22727","ASSIGNER":"cybersecurity@schneider-electric.com","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"EcoStruxure Power Monitoring Expert (Versions 2020 and prior)","version":{"version_data":[{"version_value":"EcoStruxure Power Monitoring Expert (Versions 2020 and prior)"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-20: Improper Input Validation"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-07","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-07"}]},"description":{"description_data":[{"lang":"eng","value":"A CWE-20: Improper Input Validation vulnerability exists that could allow an unauthenticated attacker to view data, change settings, impact availability of the software, or potentially impact a user�s local machine when the user clicks a specially crafted link. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)"}]}},"nvd":{"publishedDate":"2022-02-04 23:15:00","lastModifiedDate":"2023-11-07 03:43:00","problem_types":["CWE-20"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:C/I:C/A:C","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE","baseScore":9.3},"severity":"HIGH","exploitabilityScore":8.6,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:*","versionEndIncluding":"2020","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2022","CveId":"22727","Ordinal":"225148","Title":"CVE-2022-22727","CVE":"CVE-2022-22727","Year":"2022"},"notes":[{"CveYear":"2022","CveId":"22727","Ordinal":"1","NoteData":"A CWE-20: Improper Input Validation vulnerability exists that could allow an unauthenticated attacker to view data, change settings, impact availability of the software, or potentially impact a user�s local machine when the user clicks a specially crafted link. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)","Type":"Description","Title":null},{"CveYear":"2022","CveId":"22727","Ordinal":"2","NoteData":"2022-02-04","Type":"Other","Title":"Published"},{"CveYear":"2022","CveId":"22727","Ordinal":"3","NoteData":"2022-02-04","Type":"Other","Title":"Modified"}]}}}