{"api_version":"1","generated_at":"2026-04-23T14:25:34+00:00","cve":"CVE-2022-23127","urls":{"html":"https://cve.report/CVE-2022-23127","api":"https://cve.report/api/cve/CVE-2022-23127.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-23127","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-23127"},"summary":{"title":"CVE-2022-23127","description":"Cross-site Scripting vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS MobileHMI versions 10.96.2 and prior allows a remote unauthenticated attacker to gain authentication information of an MC Works64 or MobileHMI and perform any operation using the acquired authentication information, by injecting a malicious script in the URL of a monitoring screen delivered from the MC Works64 server or MobileHMI server to an application for mobile devices and leading a legitimate user to access this URL.","state":"PUBLIC","assigner":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","published_at":"2022-01-21 19:15:00","updated_at":"2022-01-27 20:03:00"},"problem_types":["CWE-79"],"metrics":[],"references":[{"url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-025_en.pdf","name":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-025_en.pdf","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://jvn.jp/vu/JVNVU95403720/index.html","name":"https://jvn.jp/vu/JVNVU95403720/index.html","refsource":"MISC","tags":[],"title":"JVNVU#95403720: 三菱電機製GENESIS64およびMC Works64における複数の脆弱性","mime":"text/xml","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01","refsource":"MISC","tags":[],"title":"ICONICS and Mitsubishi Electric HMI SCADA | CISA","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-23127","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-23127","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2022","cve_id":"23127","vulnerable":"1","versionEndIncluding":"10.96.2","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"iconics","cpe5":"mobilehmi","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"23127","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"mitsubishielectric","cpe5":"mc_works64","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2022-23127","ASSIGNER":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"Mitsubishi Electric MC Works64; ICONICS MobileHMI","version":{"version_data":[{"version_value":"Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"},{"version_value":"ICONICS MobileHMI versions 10.96.2 and prior"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Cross-site Scripting"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://jvn.jp/vu/JVNVU95403720/index.html","url":"https://jvn.jp/vu/JVNVU95403720/index.html"},{"refsource":"MISC","name":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-025_en.pdf","url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-025_en.pdf"},{"refsource":"MISC","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01","url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01"}]},"description":{"description_data":[{"lang":"eng","value":"Cross-site Scripting vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS MobileHMI versions 10.96.2 and prior allows a remote unauthenticated attacker to gain authentication information of an MC Works64 or MobileHMI and perform any operation using the acquired authentication information, by injecting a malicious script in the URL of a monitoring screen delivered from the MC Works64 server or MobileHMI server to an application for mobile devices and leading a legitimate user to access this URL."}]}},"nvd":{"publishedDate":"2022-01-21 19:15:00","lastModifiedDate":"2022-01-27 20:03:00","problem_types":["CWE-79"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE","baseScore":6.1,"baseSeverity":"MEDIUM"},"exploitabilityScore":2.8,"impactScore":2.7},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:N/I:P/A:N","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE","baseScore":4.3},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*","versionEndExcluding":"10.95.210.01","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:iconics:mobilehmi:*:*:*:*:*:*:*:*","versionEndIncluding":"10.96.2","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2022","CveId":"23127","Ordinal":"225739","Title":"CVE-2022-23127","CVE":"CVE-2022-23127","Year":"2022"},"notes":[{"CveYear":"2022","CveId":"23127","Ordinal":"1","NoteData":"Cross-site Scripting vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS MobileHMI versions 10.96.2 and prior allows a remote unauthenticated attacker to gain authentication information of an MC Works64 or MobileHMI and perform any operation using the acquired authentication information, by injecting a malicious script in the URL of a monitoring screen delivered from the MC Works64 server or MobileHMI server to an application for mobile devices and leading a legitimate user to access this URL.","Type":"Description","Title":null},{"CveYear":"2022","CveId":"23127","Ordinal":"2","NoteData":"2022-01-21","Type":"Other","Title":"Published"},{"CveYear":"2022","CveId":"23127","Ordinal":"3","NoteData":"2022-01-21","Type":"Other","Title":"Modified"}]}}}