{"api_version":"1","generated_at":"2026-04-23T06:19:48+00:00","cve":"CVE-2022-23743","urls":{"html":"https://cve.report/CVE-2022-23743","api":"https://cve.report/api/cve/CVE-2022-23743.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-23743","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-23743"},"summary":{"title":"CVE-2022-23743","description":"Check Point ZoneAlarm before version 15.8.200.19118 allows a local actor to escalate privileges during the upgrade process. In addition, weak permissions in the ProgramData\\CheckPoint\\ZoneAlarm\\Data\\Updates directory allow a local attacker the ability to execute an arbitrary file write, leading to execution of code as local system, in ZoneAlarm versions before v15.8.211.192119","state":"PUBLIC","assigner":"cve@checkpoint.com","published_at":"2022-05-11 16:15:00","updated_at":"2023-02-10 17:29:00"},"problem_types":["CWE-269","CWE-732"],"metrics":[],"references":[{"url":"https://www.zonealarm.com/software/extreme-security/release-history","name":"https://www.zonealarm.com/software/extreme-security/release-history","refsource":"MISC","tags":[],"title":"ZoneAlarm Extreme Security release history official page | ZoneAlarm","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-23743","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-23743","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2022","cve_id":"23743","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"checkpoint","cpe5":"zonealarm","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2022-23743","ASSIGNER":"cve@checkpoint.com","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"ZoneAlarm.","version":{"version_data":[{"version_value":"before v15.8.211.192119"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-269: Improper Privilege Management"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://www.zonealarm.com/software/extreme-security/release-history","url":"https://www.zonealarm.com/software/extreme-security/release-history"}]},"description":{"description_data":[{"lang":"eng","value":"Check Point ZoneAlarm before version 15.8.200.19118 allows a local actor to escalate privileges during the upgrade process. In addition, weak permissions in the ProgramData\\CheckPoint\\ZoneAlarm\\Data\\Updates directory allow a local attacker the ability to execute an arbitrary file write, leading to execution of code as local system, in ZoneAlarm versions before v15.8.211.192119"}]}},"nvd":{"publishedDate":"2022-05-11 16:15:00","lastModifiedDate":"2023-02-10 17:29:00","problem_types":["CWE-269","CWE-732"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:C/I:C/A:C","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE","baseScore":7.2},"severity":"HIGH","exploitabilityScore":3.9,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:checkpoint:zonealarm:*:*:*:*:*:*:*:*","versionEndExcluding":"15.8.211.192119","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2022","CveId":"23743","Ordinal":"226605","Title":"CVE-2022-23743","CVE":"CVE-2022-23743","Year":"2022"},"notes":[{"CveYear":"2022","CveId":"23743","Ordinal":"1","NoteData":"** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided.","Type":"Description","Title":null}]}}}