{"api_version":"1","generated_at":"2026-04-22T22:49:35+00:00","cve":"CVE-2022-24287","urls":{"html":"https://cve.report/CVE-2022-24287","api":"https://cve.report/api/cve/CVE-2022-24287.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-24287","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-24287"},"summary":{"title":"CVE-2022-24287","description":"A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC06), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1 UC01), SIMATIC WinCC Runtime Professional V16 and earlier (All versions), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Upd4), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP 1 Update 21), SIMATIC WinCC V7.5 (All versions < V7.5 SP 2 Update 8). A missing printer configuration on the host could allow an authenticated attacker to escape the WinCC Kiosk Mode.","state":"PUBLIC","assigner":"productcert@siemens.com","published_at":"2022-05-20 13:15:00","updated_at":"2023-11-14 11:15:00"},"problem_types":["CWE-1188"],"metrics":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-363107.pdf","name":"N/A","refsource":"CONFIRM","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-24287","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-24287","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2022","cve_id":"24287","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_pcs_7","cpe6":"9.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"24287","vulnerable":"1","versionEndIncluding":"9.0","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_pcs_7","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"24287","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.5","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"24287","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.5","cpe7":"sp1","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"24287","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.5","cpe7":"sp1_update1","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"24287","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.5","cpe7":"sp1_update2","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"24287","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.5","cpe7":"sp2","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"24287","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.5","cpe7":"sp2_update1","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"24287","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.5","cpe7":"sp2_update2","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"24287","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.5","cpe7":"sp2_update3","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"24287","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.5","cpe7":"sp2_update4","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"24287","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.5","cpe7":"sp2_update5","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"24287","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.5","cpe7":"sp2_update6","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"24287","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.5","cpe7":"sp2_update7","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"24287","vulnerable":"1","versionEndIncluding":"7.4","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"24287","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc_runtime_professional","cpe6":"17","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"24287","vulnerable":"1","versionEndIncluding":"16","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc_runtime_professional","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2022-24287","qid":"591050","title":"Siemens SIMATIC WinCC Vulnerability (SSA-363107) (icsa-22-132-06)"}]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2022-24287","ASSIGNER":"productcert@siemens.com","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC06), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1 UC01), SIMATIC WinCC Runtime Professional V16 and earlier (All versions), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Upd4), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP 1 Update 21), SIMATIC WinCC V7.5 (All versions < V7.5 SP 2 Update 8). A missing printer configuration on the host could allow an authenticated attacker to escape the WinCC Kiosk Mode."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-1188: Insecure Default Initialization of Resource","cweId":"CWE-1188"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Siemens","product":{"product_data":[{"product_name":"SIMATIC PCS 7 V8.2","version":{"version_data":[{"version_affected":"=","version_value":"All versions"}]}},{"product_name":"SIMATIC PCS 7 V9.0","version":{"version_data":[{"version_affected":"=","version_value":"All versions < V9.0 SP3 UC06"}]}},{"product_name":"SIMATIC PCS 7 V9.1","version":{"version_data":[{"version_affected":"=","version_value":"All versions < V9.1 SP1 UC01"}]}},{"product_name":"SIMATIC WinCC Runtime Professional V16 and earlier","version":{"version_data":[{"version_affected":"=","version_value":"All versions"}]}},{"product_name":"SIMATIC WinCC Runtime Professional V17","version":{"version_data":[{"version_affected":"=","version_value":"All versions < V17 Upd4"}]}},{"product_name":"SIMATIC WinCC V7.3","version":{"version_data":[{"version_affected":"=","version_value":"All versions"}]}},{"product_name":"SIMATIC WinCC V7.4","version":{"version_data":[{"version_affected":"=","version_value":"All versions < V7.4 SP 1 Update 21"}]}},{"product_name":"SIMATIC WinCC V7.5","version":{"version_data":[{"version_affected":"=","version_value":"All versions < V7.5 SP 2 Update 8"}]}}]}}]}},"references":{"reference_data":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-363107.pdf","refsource":"MISC","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-363107.pdf"}]},"impact":{"cvss":[{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","baseScore":7.8,"baseSeverity":"HIGH"}]}},"nvd":{"publishedDate":"2022-05-20 13:15:00","lastModifiedDate":"2023-11-14 11:15:00","problem_types":["CWE-1188"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:P/A:P","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":4.6},"severity":"MEDIUM","exploitabilityScore":3.9,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*","versionEndIncluding":"7.4","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update1:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update2:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.5:sp2:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update1:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update2:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update3:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update4:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_pcs_7:9.1:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update5:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*","versionEndIncluding":"9.0","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*","versionEndIncluding":"16","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc_runtime_professional:17:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update6:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update7:*:*:*:*:*:*","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2022","CveId":"24287","Ordinal":"227568","Title":"CVE-2022-24287","CVE":"CVE-2022-24287","Year":"2022"},"notes":[{"CveYear":"2022","CveId":"24287","Ordinal":"1","NoteData":"** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided.","Type":"Description","Title":null}]}}}