{"api_version":"1","generated_at":"2026-04-22T22:50:47+00:00","cve":"CVE-2022-24290","urls":{"html":"https://cve.report/CVE-2022-24290","api":"https://cve.report/api/cve/CVE-2022-24290.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-24290","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-24290"},"summary":{"title":"CVE-2022-24290","description":"A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.13), Teamcenter V13.0 (All versions < V13.0.0.9), Teamcenter V13.1 (All versions), Teamcenter V13.2 (All versions < V13.2.0.8), Teamcenter V13.3 (All versions < V13.3.0.3), Teamcenter V14.0 (All versions < V14.0.0.2). The tcserver.exe binary in affected applications is vulnerable to a stack overflow condition during the parsing of user input that may lead the binary to crash.","state":"PUBLIC","assigner":"productcert@siemens.com","published_at":"2022-05-20 13:15:00","updated_at":"2023-02-23 18:08:00"},"problem_types":["CWE-121"],"metrics":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf","name":"N/A","refsource":"CONFIRM","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-24290","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-24290","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2022","cve_id":"24290","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"teamcenter","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"24290","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"teamcenter","cpe6":"14.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"24290","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"teamcenter_visualization","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"24290","vulnerable":"1","versionEndIncluding":"13.1.0.3","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"teamcenter_visualization","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2022-24290","STATE":"PUBLIC"},"data_format":"MITRE","data_version":"4.0","data_type":"CVE","affects":{"vendor":{"vendor_data":[{"vendor_name":"Siemens","product":{"product_data":[{"product_name":"Teamcenter V12.4","version":{"version_data":[{"version_value":"All versions < V12.4.0.13"}]}},{"product_name":"Teamcenter V13.0","version":{"version_data":[{"version_value":"All versions < V13.0.0.9"}]}},{"product_name":"Teamcenter V13.1","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"Teamcenter V13.2","version":{"version_data":[{"version_value":"All versions < V13.2.0.8"}]}},{"product_name":"Teamcenter V13.3","version":{"version_data":[{"version_value":"All versions < V13.3.0.3"}]}},{"product_name":"Teamcenter V14.0","version":{"version_data":[{"version_value":"All versions < V14.0.0.2"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-121: Stack-based Buffer Overflow"}]}]},"description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.13), Teamcenter V13.0 (All versions < V13.0.0.9), Teamcenter V13.1 (All versions), Teamcenter V13.2 (All versions < V13.2.0.8), Teamcenter V13.3 (All versions < V13.3.0.3), Teamcenter V14.0 (All versions < V14.0.0.2). The tcserver.exe binary in affected applications is vulnerable to a stack overflow condition during the parsing of user input that may lead the binary to crash."}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf"}]}},"nvd":{"publishedDate":"2022-05-20 13:15:00","lastModifiedDate":"2023-02-23 18:08:00","problem_types":["CWE-121"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL","baseScore":5},"severity":"MEDIUM","exploitabilityScore":10,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:teamcenter:14.0:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*","versionStartIncluding":"13.3","versionEndExcluding":"13.3.0.3","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*","versionStartIncluding":"13.2","versionEndExcluding":"13.2.0.8","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*","versionStartIncluding":"13.0","versionEndExcluding":"13.0.0.9","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*","versionStartIncluding":"13.1","versionEndExcluding":"13.1.0.9","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*","versionStartIncluding":"12.4","versionEndExcluding":"12.4.0.13","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2022","CveId":"24290","Ordinal":"227587","Title":"CVE-2022-24290","CVE":"CVE-2022-24290","Year":"2022"},"notes":[{"CveYear":"2022","CveId":"24290","Ordinal":"1","NoteData":"** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided.","Type":"Description","Title":null}]}}}