{"api_version":"1","generated_at":"2026-04-22T23:32:08+00:00","cve":"CVE-2022-24319","urls":{"html":"https://cve.report/CVE-2022-24319","api":"https://cve.report/api/cve/CVE-2022-24319.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-24319","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-24319"},"summary":{"title":"CVE-2022-24319","description":"A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA web server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2022-02-09 23:15:00","updated_at":"2022-04-22 16:01:00"},"problem_types":["CWE-295"],"metrics":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-05","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-05","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://github.com/mandiant/Vulnerability-Disclosures/blob/master/2022/MNDT-2022-0018/MNDT-2022-0018.md","name":"https://github.com/mandiant/Vulnerability-Disclosures/blob/master/2022/MNDT-2022-0018/MNDT-2022-0018.md","refsource":"MISC","tags":[],"title":"Vulnerability-Disclosures/MNDT-2022-0018.md at master · mandiant/Vulnerability-Disclosures · GitHub","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-24319","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-24319","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2022","cve_id":"24319","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"clearscada","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"24319","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"ecostruxure_geo_scada_expert_2019","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"24319","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"ecostruxure_geo_scada_expert_2020","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2022-24319","qid":"590722","title":"Schneider Electric EcoStruxure Geo SCADA Expert Multiple Vulnerabilities (SEVD-2022-039-05)"}]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2022-24319","ASSIGNER":"cybersecurity@schneider-electric.com","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)","version":{"version_data":[{"version_value":"ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-295: Improper Certificate Validation"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-05","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-05"},{"refsource":"MISC","name":"https://github.com/mandiant/Vulnerability-Disclosures/blob/master/2022/MNDT-2022-0018/MNDT-2022-0018.md","url":"https://github.com/mandiant/Vulnerability-Disclosures/blob/master/2022/MNDT-2022-0018/MNDT-2022-0018.md"}]},"description":{"description_data":[{"lang":"eng","value":"A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA web server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)"}]}},"nvd":{"publishedDate":"2022-02-09 23:15:00","lastModifiedDate":"2022-04-22 16:01:00","problem_types":["CWE-295"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":5.9,"baseSeverity":"MEDIUM"},"exploitabilityScore":2.2,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:N/A:N","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":4.3},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:*:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:clearscada:-:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:*:*:*:*:*:*:*:*","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2022","CveId":"24319","Ordinal":"227644","Title":"CVE-2022-24319","CVE":"CVE-2022-24319","Year":"2022"},"notes":[{"CveYear":"2022","CveId":"24319","Ordinal":"1","NoteData":"A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA web server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)","Type":"Description","Title":null},{"CveYear":"2022","CveId":"24319","Ordinal":"2","NoteData":"2022-02-09","Type":"Other","Title":"Published"},{"CveYear":"2022","CveId":"24319","Ordinal":"3","NoteData":"2022-02-09","Type":"Other","Title":"Modified"}]}}}