{"api_version":"1","generated_at":"2026-04-23T04:42:20+00:00","cve":"CVE-2022-24352","urls":{"html":"https://cve.report/CVE-2022-24352","api":"https://cve.report/api/cve/CVE-2022-24352.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-24352","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-24352"},"summary":{"title":"CVE-2022-24352","description":"This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of TP-Link AC1750 prior to 211210 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the NetUSB.ko kernel module. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-15773.","state":"PUBLIC","assigner":"zdi-disclosures@trendmicro.com","published_at":"2023-03-28 19:15:00","updated_at":"2023-04-06 19:14:00"},"problem_types":["CWE-125"],"metrics":[],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-262/","name":"https://www.zerodayinitiative.com/advisories/ZDI-22-262/","refsource":"MISC","tags":[],"title":"ZDI-22-262 | Zero Day Initiative","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-24352","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-24352","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2022","cve_id":"24352","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tp-link","cpe5":"ac1750","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"24352","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"ac1750_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"zdi-disclosures@trendmicro.com","ID":"CVE-2022-24352","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"AC1750","version":{"version_data":[{"version_value":"prior to 211210"}]}}]},"vendor_name":"TP-Link"}]}},"credit":"trichimtrich and nyancat0131","data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of TP-Link AC1750 prior to 211210 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the NetUSB.ko kernel module. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-15773."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-125: Out-of-bounds Read"}]}]},"references":{"reference_data":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-262/","refsource":"MISC","name":"https://www.zerodayinitiative.com/advisories/ZDI-22-262/"}]},"impact":{"cvss":{"vectorString":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"}}},"nvd":{"publishedDate":"2023-03-28 19:15:00","lastModifiedDate":"2023-04-06 19:14:00","problem_types":["CWE-125"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:tp-link:ac1750_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"211210","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:tp-link:ac1750:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2022","CveId":"24352","Ordinal":"227679","Title":"CVE-2022-24352","CVE":"CVE-2022-24352","Year":"2022"},"notes":[{"CveYear":"2022","CveId":"24352","Ordinal":"1","NoteData":"** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided.","Type":"Description","Title":null}]}}}