{"api_version":"1","generated_at":"2026-07-23T20:14:43+00:00","cve":"CVE-2022-2641","urls":{"html":"https://cve.report/CVE-2022-2641","api":"https://cve.report/api/cve/CVE-2022-2641.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-2641","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-2641"},"summary":{"title":"CVE-2022-2641","description":"Horner Automation’s RCC 972 with firmware version 15.40 has a static encryption key on the device. This could allow an attacker to perform unauthorized changes to the device, remotely execute arbitrary code, or cause a denial-of-service condition.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2022-12-02 20:15:00","updated_at":"2022-12-06 12:33:00"},"problem_types":["CWE-321"],"metrics":[],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-335-02","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-335-02","refsource":"MISC","tags":[],"title":"Horner Automation Remote Compact Controller | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-2641","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-2641","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"LEGACY","value":"m1etz reported these vulnerabilities through the Computer Emergency Response Team, CERT-Bund, to CISA","lang":""}],"nvd_cpes":[{"cve_year":"2022","cve_id":"2641","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hornerautomation","cpe5":"rcc972","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"2641","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hornerautomation","cpe5":"rcc972_firmware","cpe6":"15.40","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2022-2641","qid":"591343","title":"Horner Automation Remote Compact Controller Inadequate Encryption Strength, Use of Hard-coded Cryptographic Key, Excessive Reliance on Global Variables Multiple Vulnerabilities (ICSA-22-335-02)"}]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","DATE_PUBLIC":"2022-12-01T19:25:00.000Z","ID":"CVE-2022-2641","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Remote Compact Controller (RCC) 972","version":{"version_data":[{"version_affected":"=","version_name":"Firmware Version","version_value":"15.40"}]}}]},"vendor_name":"Horner Automation"}]}},"credit":[{"lang":"eng","value":"m1etz reported these vulnerabilities through the Computer Emergency Response Team, CERT-Bund, to CISA"}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Horner Automation’s RCC 972 with firmware version 15.40 has a static encryption key on the device. This could allow an attacker to perform unauthorized changes to the device, remotely execute arbitrary code, or cause a denial-of-service condition."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-321 Use of Hard-coded Cryptographic Key"}]}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-335-02","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-335-02"}]},"source":{"discovery":"UNKNOWN"}},"nvd":{"publishedDate":"2022-12-02 20:15:00","lastModifiedDate":"2022-12-06 12:33:00","problem_types":["CWE-321"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":5.9}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:hornerautomation:rcc972_firmware:15.40:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:hornerautomation:rcc972:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":null,"notes":[]}}}