{"api_version":"1","generated_at":"2026-04-23T09:05:52+00:00","cve":"CVE-2022-2788","urls":{"html":"https://cve.report/CVE-2022-2788","api":"https://cve.report/api/cve/CVE-2022-2788.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-2788","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-2788"},"summary":{"title":"CVE-2022-2788","description":"Emerson Electric's Proficy Machine Edition Version 9.80 and prior is vulnerable to CWE-29 Path Traversal: '\\..\\Filename', also known as a ZipSlip attack, through an upload procedure which enables attackers to implant a malicious .BLZ file on the PLC. The file can transfer through the engineering station onto Windows in a way that executes the malicious code.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2022-08-19 21:15:00","updated_at":"2023-06-28 14:25:00"},"problem_types":["CWE-22"],"metrics":[],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-06","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-06","refsource":"MISC","tags":[],"title":"Emerson Proficy Machine Edition | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-2788","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-2788","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"LEGACY","value":"Sharon Brizinov of Claroty reported this vulnerability to Emerson and CISA","lang":""}],"nvd_cpes":[{"cve_year":"2022","cve_id":"2788","vulnerable":"1","versionEndIncluding":"9.80","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"emerson","cpe5":"electric\\'s_proficy","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"machine","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2022-2788","qid":"591059","title":"Emerson Proficy Machine Edition Multiple Vulnerabilities (ICSA-22-228-06)"}]},"source_records":{"cve_program":{"CVE_data_meta":{"AKA":"ZipSlip","ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2022-2788","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Proficy Machine Edition","version":{"version_data":[{"version_affected":"<=","version_name":"all","version_value":"9.80"}]}}]},"vendor_name":"Emerson Electric"}]}},"credit":[{"lang":"eng","value":"Sharon Brizinov of Claroty reported this vulnerability to Emerson and CISA"}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Emerson Electric's Proficy Machine Edition Version 9.80 and prior is vulnerable to CWE-29 Path Traversal: '\\..\\Filename', also known as a ZipSlip attack, through an upload procedure which enables attackers to implant a malicious .BLZ file on the PLC. The file can transfer through the engineering station onto Windows in a way that executes the malicious code."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"LOW","baseScore":3.9,"baseSeverity":"LOW","confidentialityImpact":"NONE","integrityImpact":"LOW","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:L","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-29 Path Traversal: '\\..\\Filename'"}]}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-06","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-06"}]},"source":{"discovery":"UNKNOWN"}},"nvd":{"publishedDate":"2022-08-19 21:15:00","lastModifiedDate":"2023-06-28 14:25:00","problem_types":["CWE-22"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.3,"baseSeverity":"HIGH"},"exploitabilityScore":1.3,"impactScore":5.9}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:emerson:electric\\'s_proficy:*:*:*:*:machine:*:*:*","versionEndIncluding":"9.80","cpe_name":[]}]}]}},"legacy_mitre":{"record":null,"notes":[]}}}