{"api_version":"1","generated_at":"2026-04-24T14:23:12+00:00","cve":"CVE-2022-29830","urls":{"html":"https://cve.report/CVE-2022-29830","api":"https://cve.report/api/cve/CVE-2022-29830.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-29830","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-29830"},"summary":{"title":"CVE-2022-29830","description":"Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally.","state":"PUBLIC","assigner":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","published_at":"2022-11-25 00:15:00","updated_at":"2023-06-29 08:15:00"},"problem_types":["CWE-798"],"metrics":[],"references":[{"url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf","name":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"200"},{"url":"https://jvn.jp/vu/JVNVU97244961/index.html","name":"https://jvn.jp/vu/JVNVU97244961/index.html","refsource":"MISC","tags":[],"title":"JVNVU#97244961: 三菱電機製FAエンジニアリングソフトウェア製品における複数の脆弱性","mime":"text/xml","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05","refsource":"MISC","tags":[],"title":"Mitsubishi Electric FA Engineering Software | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-29830","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-29830","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2022","cve_id":"29830","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"mitsubishielectric","cpe5":"gx_works3","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"29830","vulnerable":"1","versionEndIncluding":"1.011m","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"mitsubishielectric","cpe5":"gx_works3","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"29830","vulnerable":"1","versionEndIncluding":"1.086q","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"mitsubishielectric","cpe5":"gx_works3","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2022-29830","qid":"591227","title":"Mitsubishi Electric FA Engineering Software GXWorks3 Multiple Vulnerabilities (ICSA-22-333-05)"}]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2022-29830","ASSIGNER":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-321 Use of Hard-coded Cryptographic Key","cweId":"CWE-321"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Mitsubishi Electric Corporation","product":{"product_data":[{"product_name":"GX Works3","version":{"version_data":[{"version_affected":"=","version_value":"from 1.000A to 1.095Z"}]}},{"product_name":"Motion Control Setting(GX Works3 related software)","version":{"version_data":[{"version_affected":"=","version_value":"from 1.000A and later"}]}}]}}]}},"references":{"reference_data":[{"url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf","refsource":"MISC","name":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"},{"url":"https://jvn.jp/vu/JVNVU97244961/index.html","refsource":"MISC","name":"https://jvn.jp/vu/JVNVU97244961/index.html"},{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05","refsource":"MISC","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"}]},"generator":{"engine":"Vulnogram 0.1.0-dev"},"source":{"discovery":"UNKNOWN"},"impact":{"cvss":[{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":9.1,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","version":"3.1"}]}},"nvd":{"publishedDate":"2022-11-25 00:15:00","lastModifiedDate":"2023-06-29 08:15:00","problem_types":["CWE-798"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE","baseScore":9.1,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":5.2}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*","versionStartIncluding":"1.087r","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*","versionStartIncluding":"1.015r","versionEndIncluding":"1.086q","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*","versionStartIncluding":"1.000a","versionEndIncluding":"1.011m","cpe_name":[]}]}]}},"legacy_mitre":{"record":null,"notes":[]}}}