{"api_version":"1","generated_at":"2026-05-13T19:41:21+00:00","cve":"CVE-2022-2988","urls":{"html":"https://cve.report/CVE-2022-2988","api":"https://cve.report/api/cve/CVE-2022-2988.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-2988","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-2988"},"summary":{"title":"CVE-2022-2988","description":"A CWE-787: Out-of-bounds Write vulnerability exists that could cause sensitive information leakage when accessing a malicious web page from the commissioning software. Affected Products: SoMachine HVAC (Versions prior to V2.1.0), EcoStruxure Machine Expert – HVAC (Versions prior to V1.4.0)","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2023-01-30 11:15:00","updated_at":"2023-02-07 17:34:00"},"problem_types":["CWE-787"],"metrics":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-01_EcoStruxure_Machine_Expert_Machine_HVAC_Security_Notification.pdf","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-01_EcoStruxure_Machine_Expert_Machine_HVAC_Security_Notification.pdf","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"-1","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-2988","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-2988","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2022","cve_id":"2988","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"ecostruxure_machine_expert_-_hvac","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"2988","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"somachine_hvac","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","ID":"CVE-2022-2988","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"SoMachine HVAC","version":{"version_data":[{"version_affected":"<","version_name":"All","version_value":"V2.1.0"}]}},{"product_name":"EcoStruxure Machine Expert – HVAC","version":{"version_data":[{"version_affected":"<","version_name":"All","version_value":"V1.4.0"}]}}]},"vendor_name":"Schneider Electric"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A CWE-787: Out-of-bounds Write vulnerability exists that could cause sensitive information leakage when accessing a malicious web page from the commissioning software. Affected Products: SoMachine HVAC (Versions prior to V2.1.0), EcoStruxure Machine Expert – HVAC (Versions prior to V1.4.0)"}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":4.3,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-787 Out-of-bounds Write"}]}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-01_EcoStruxure_Machine_Expert_Machine_HVAC_Security_Notification.pdf","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-01_EcoStruxure_Machine_Expert_Machine_HVAC_Security_Notification.pdf"}]},"source":{"discovery":"UNKNOWN"}},"nvd":{"publishedDate":"2023-01-30 11:15:00","lastModifiedDate":"2023-02-07 17:34:00","problem_types":["CWE-787"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:somachine_hvac:*:*:*:*:*:*:*:*","versionEndExcluding":"2.1.0","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:ecostruxure_machine_expert_-_hvac:*:*:*:*:*:*:*:*","versionEndExcluding":"1.4.0","cpe_name":[]}]}]}},"legacy_mitre":{"record":null,"notes":[]}}}