{"api_version":"1","generated_at":"2026-07-24T18:34:00+00:00","cve":"CVE-2022-31465","urls":{"html":"https://cve.report/CVE-2022-31465","api":"https://cve.report/api/cve/CVE-2022-31465.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-31465","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-31465"},"summary":{"title":"CVE-2022-31465","description":"A vulnerability has been identified in Xpedition Designer VX.2.10 (All versions < VX.2.10 Update 13), Xpedition Designer VX.2.11 (All versions < VX.2.11 Update 11), Xpedition Designer VX.2.12 (All versions < VX.2.12 Update 5), Xpedition Designer VX.2.13 (All versions < VX.2.13 Update 1). The affected application assigns improper access rights to the service executable. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges.","state":"PUBLIC","assigner":"productcert@siemens.com","published_at":"2022-06-14 10:15:00","updated_at":"2023-06-13 09:15:00"},"problem_types":["CWE-732"],"metrics":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-988345.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-988345.pdf","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-31465","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-31465","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2022","cve_id":"31465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"xpedition_designer","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2022-31465","ASSIGNER":"productcert@siemens.com","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in Xpedition Designer VX.2.10 (All versions < VX.2.10 Update 13), Xpedition Designer VX.2.11 (All versions < VX.2.11 Update 11), Xpedition Designer VX.2.12 (All versions < VX.2.12 Update 5), Xpedition Designer VX.2.13 (All versions < VX.2.13 Update 1). The affected application assigns improper access rights to the service executable. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-732: Incorrect Permission Assignment for Critical Resource","cweId":"CWE-732"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Siemens","product":{"product_data":[{"product_name":"Xpedition Designer VX.2.10","version":{"version_data":[{"version_affected":"=","version_value":"All versions < VX.2.10 Update 13"}]}},{"product_name":"Xpedition Designer VX.2.11","version":{"version_data":[{"version_affected":"=","version_value":"All versions < VX.2.11 Update 11"}]}},{"product_name":"Xpedition Designer VX.2.12","version":{"version_data":[{"version_affected":"=","version_value":"All versions < VX.2.12 Update 5"}]}},{"product_name":"Xpedition Designer VX.2.13","version":{"version_data":[{"version_affected":"=","version_value":"All versions < VX.2.13 Update 1"}]}}]}}]}},"references":{"reference_data":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-988345.pdf","refsource":"MISC","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-988345.pdf"}]},"impact":{"cvss":[{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","baseScore":7.8,"baseSeverity":"HIGH"}]}},"nvd":{"publishedDate":"2022-06-14 10:15:00","lastModifiedDate":"2023-06-13 09:15:00","problem_types":["CWE-732"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:P/A:P","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":4.6},"severity":"MEDIUM","exploitabilityScore":3.9,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:xpedition_designer:*:*:*:*:*:*:*:*","versionEndExcluding":"vx.2.11","cpe_name":[]}]}]}},"legacy_mitre":{"record":null,"notes":[]}}}