{"api_version":"1","generated_at":"2026-07-23T09:46:32+00:00","cve":"CVE-2022-3159","urls":{"html":"https://cve.report/CVE-2022-3159","api":"https://cve.report/api/cve/CVE-2022-3159.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-3159","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-3159"},"summary":{"title":"CVE-2022-3159","description":"The APDFL.dll contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2023-01-13 01:15:00","updated_at":"2023-11-07 03:50:00"},"problem_types":["CWE-787"],"metrics":[],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15","refsource":"MISC","tags":[],"title":"Siemens Teamcenter Visualization and JT2Go | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json","name":"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json","refsource":"MISC","tags":[],"title":"","mime":"application/json","httpstatus":"200","archivestatus":"200"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-360681.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-360681.html","refsource":"MISC","tags":[],"title":"SSA-360681","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-3159","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-3159","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2022","cve_id":"3159","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"jt2go","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"3159","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"teamcenter_visualization","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2022-3159","qid":"591305","title":"Siemens J2TGo Multiple Vulnerabilities (SSA-360681)"}]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2022-3159","ASSIGNER":"ics-cert@hq.dhs.gov","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"The APDFL.dll contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-121 ","cweId":"CWE-121"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Siemens ","product":{"product_data":[{"product_name":"JT2Go","version":{"version_data":[{"version_value":"0","version_affected":"="}]}},{"product_name":"Teamcenter Visualization V13.3","version":{"version_data":[{"version_value":"0","version_affected":"="}]}},{"product_name":"Teamcenter Visualization V14.0","version":{"version_data":[{"version_value":"0","version_affected":"="}]}},{"product_name":"Teamcenter Visualization V14.1","version":{"version_data":[{"version_value":"0","version_affected":"="}]}}]}}]}},"references":{"reference_data":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15","refsource":"MISC","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-360681.html","refsource":"MISC","name":"https://cert-portal.siemens.com/productcert/html/ssa-360681.html"},{"url":"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json","refsource":"MISC","name":"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json"}]},"generator":{"engine":"Vulnogram 0.1.0-dev"},"source":{"discovery":"EXTERNAL"},"work_around":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n<p>Siemens identified the following specific workaround and mitigation user can apply to reduce risk: </p>\n\n<ul><li>Do not open untrusted PDF files in JT2Go and Teamcenter Visualization.</li>\n</ul><p>As a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens' <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/operational-guidelines-industrial-security\">operational guidelines for industrial security</a></p> and following the recommendations in the product manuals. Siemens also provides <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/industrialsecurity\">additional information on industrial security</a>.<br>\nFor further inquiries on security vulnerabilities in Siemens products, users should contact <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/advisories\">Siemens</a>. <br>\nFor more information, see the associated Siemens security advisory SSA-360681 in <a target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/html/ssa-360681.html\">HTML </a>and <a target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json\">CSAF</a>.\n\n<br>"}],"value":"Siemens identified the following specific workaround and mitigation user can apply to reduce risk: \n\n\n\n  *  Do not open untrusted PDF files in JT2Go and Teamcenter Visualization.\n\n\n\nAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens'  operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security \n\n and following the recommendations in the product manuals. Siemens also provides  additional information on industrial security https://www.siemens.com/industrialsecurity .\n\nFor further inquiries on security vulnerabilities in Siemens products, users should contact  Siemens https://www.siemens.com/cert/advisories . \n\nFor more information, see the associated Siemens security advisory SSA-360681 in  HTML  https://cert-portal.siemens.com/productcert/html/ssa-360681.html and  CSAF https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json .\n\n\n"}],"solution":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\nSiemens released updates for the affected products and recommends updating to the latest versions:<br><ul><li><span style=\"background-color: var(--wht);\">JT2Go: </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html\">Update to V14.1.0.5 or later version</a><span style=\"background-color: var(--wht);\">.&nbsp;<br></span></li><li><span style=\"background-color: var(--wht);\">Teamcenter Visualization V13.3: </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\">Update to V13.3.0.8 or later version</a><span style=\"background-color: var(--wht);\">.<br></span></li><li><span style=\"background-color: var(--wht);\">Teamcenter Visualization V14.0: </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\">Update to V14.0.0.4 or later version</a><span style=\"background-color: var(--wht);\">.<br></span></li><li><span style=\"background-color: var(--wht);\">Teamcenter Visualization V14.1: </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\">Update to V14.1.0.5 or later version</a><span style=\"background-color: var(--wht);\">.</span></li></ul>"}],"value":"Siemens released updates for the affected products and recommends updating to the latest versions:\n  *  JT2Go:  Update to V14.1.0.5 or later version https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html . \n\n  *  Teamcenter Visualization V13.3:  Update to V13.3.0.8 or later version https://support.sw.siemens.com/ .\n\n  *  Teamcenter Visualization V14.0:  Update to V14.0.0.4 or later version https://support.sw.siemens.com/ .\n\n  *  Teamcenter Visualization V14.1:  Update to V14.1.0.5 or later version https://support.sw.siemens.com/ .\n\n\n"}],"credits":[{"lang":"en","value":"Michael Heinz and Nafiez reported these vulnerabilities to Siemens. "}],"impact":{"cvss":[{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"}]}},"nvd":{"publishedDate":"2023-01-13 01:15:00","lastModifiedDate":"2023-11-07 03:50:00","problem_types":["CWE-787"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*","versionStartIncluding":"13.3.0","versionEndExcluding":"13.3.0.8","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*","versionStartIncluding":"14.1","versionEndExcluding":"14.1.0.5","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*","versionStartIncluding":"14.0.0","versionEndExcluding":"14.0.0.4","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*","versionEndExcluding":"14.1.0.5","cpe_name":[]}]}]}},"legacy_mitre":{"record":null,"notes":[]}}}