{"api_version":"1","generated_at":"2026-07-23T11:54:54+00:00","cve":"CVE-2022-32530","urls":{"html":"https://cve.report/CVE-2022-32530","api":"https://cve.report/api/cve/CVE-2022-32530.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-32530","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-32530"},"summary":{"title":"CVE-2022-32530","description":"A CWE-668 Exposure of Resource to Wrong Sphere vulnerability exists that could cause users to be misled, hiding alarms, showing the wrong server connection option or the wrong control request when a mobile device has been compromised by a malicious application. Affected Product: Geo SCADA Mobile (Build 222 and prior)","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2022-06-24 13:15:00","updated_at":"2022-07-06 17:11:00"},"problem_types":["CWE-668"],"metrics":[],"references":[{"url":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf","name":"N/A","refsource":"CONFIRM","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-32530","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-32530","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2022","cve_id":"32530","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"geo_scada_mobile","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"android","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"32530","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"geo_scada_mobile","cpe6":"2020","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"android","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"32530","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"geo_scada_mobile","cpe6":"2020","cpe7":"build_222","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"android","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","ID":"CVE-2022-32530","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Geo SCADA Mobile","version":{"version_data":[{"version_affected":"<=","version_name":"Build","version_value":"222"}]}}]},"vendor_name":"Schneider Electric"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A CWE-668 Exposure of Resource to Wrong Sphere vulnerability exists that could cause users to be misled, hiding alarms, showing the wrong server connection option or the wrong control request when a mobile device has been compromised by a malicious application. Affected Product: Geo SCADA Mobile (Build 222 and prior)"}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"LOW","baseScore":4.8,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-668 Exposure of Resource to Wrong Sphere"}]}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf","name":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf"}]},"source":{"discovery":"UNKNOWN"}},"nvd":{"publishedDate":"2022-06-24 13:15:00","lastModifiedDate":"2022-07-06 17:11:00","problem_types":["CWE-668"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":6.8},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:geo_scada_mobile:*:*:*:*:*:android:*:*","versionEndExcluding":"2020","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:geo_scada_mobile:2020:-:*:*:*:android:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:geo_scada_mobile:2020:build_222:*:*:*:android:*:*","cpe_name":[]}]}]}},"legacy_mitre":{"record":null,"notes":[]}}}