{"api_version":"1","generated_at":"2026-04-23T04:11:13+00:00","cve":"CVE-2022-32534","urls":{"html":"https://cve.report/CVE-2022-32534","api":"https://cve.report/api/cve/CVE-2022-32534.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-32534","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-32534"},"summary":{"title":"CVE-2022-32534","description":"The Bosch Ethernet switch PRA-ES8P2S with software version 1.01.05 and earlier was found to be vulnerable to command injection through its diagnostics web interface. This allows execution of shell commands.","state":"PUBLIC","assigner":"psirt@bosch.com","published_at":"2022-06-23 17:15:00","updated_at":"2023-06-29 14:24:00"},"problem_types":["CWE-78"],"metrics":[],"references":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-247052-BT.html","name":"https://psirt.bosch.com/security-advisories/BOSCH-SA-247052-BT.html","refsource":"CONFIRM","tags":[],"title":"Multiple Vulnerabilities PRA-ES8P2S Ethernet-Switch | Bosch PSIRT","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-32534","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-32534","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2022","cve_id":"32534","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"bosch","cpe5":"pra-es8p2s","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"32534","vulnerable":"1","versionEndIncluding":"1.01.05","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"bosch","cpe5":"pra-es8p2s_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2022-32534","ASSIGNER":"psirt@bosch.com","TITLE":"OS Command Injection ","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Bosch","product":{"product_data":[{"product_name":"PRA-ES8P2S","version":{"version_data":[{"version_value":"1.01.05","version_affected":"<="}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-20 Improper Input Validation"}]}]},"impact":{"cvss":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH"}},"references":{"reference_data":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-247052-BT.html","name":"https://psirt.bosch.com/security-advisories/BOSCH-SA-247052-BT.html","refsource":"CONFIRM"}]},"description":{"description_data":[{"lang":"eng","value":"The Bosch Ethernet switch PRA-ES8P2S with software version 1.01.05 and earlier was found to be vulnerable to command injection through its diagnostics web interface. This allows execution of shell commands."}]},"source":{"advisory":"BOSCH-SA-247052-BT ","discovery":"INTERNAL"}},"nvd":{"publishedDate":"2022-06-23 17:15:00","lastModifiedDate":"2023-06-29 14:24:00","problem_types":["CWE-78"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE","baseScore":10},"severity":"HIGH","exploitabilityScore":10,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:bosch:pra-es8p2s_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"1.01.05","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:bosch:pra-es8p2s:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":null,"notes":[]}}}