{"api_version":"1","generated_at":"2026-07-23T14:29:48+00:00","cve":"CVE-2022-32748","urls":{"html":"https://cve.report/CVE-2022-32748","api":"https://cve.report/api/cve/CVE-2022-32748.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-32748","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-32748"},"summary":{"title":"CVE-2022-32748","description":"A CWE-295: Improper Certificate Validation vulnerability exists that could cause the CAE software to give wrong data to end users when using CAE to configure devices. Additionally, credentials could leak which would enable an attacker the ability to log into the configuration tool and compromise other devices in the network. Affected Products: EcoStruxure™ Cybersecurity Admin Expert (CAE) (Versions prior to 2.2)","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2023-01-30 23:15:00","updated_at":"2023-04-03 17:44:00"},"problem_types":["CWE-295"],"metrics":[],"references":[{"url":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf","name":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf","refsource":"MISC","tags":[],"title":"","mime":"","httpstatus":"-1","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-32748","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-32748","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2022","cve_id":"32748","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"ecostruxure_cybersecurity_admin_expert","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2022-32748","qid":"591044","title":"Schneider Electric EcoStruxure Cybersecurity Admin Expert Multiple Vulnerabilities (SEVD-2022-165-08)"}]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","DATE_PUBLIC":"2022-06-14T07:00:00.000Z","ID":"CVE-2022-32748","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"EcoStruxure™ Cybersecurity Admin Expert (CAE)","version":{"version_data":[{"version_affected":"<","version_name":"All","version_value":"2.2"}]}}]},"vendor_name":"Schneider Electric"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A CWE-295: Improper Certificate Validation vulnerability exists that could cause the CAE software to give wrong data to end users when using CAE to configure devices. Additionally, credentials could leak which would enable an attacker the ability to log into the configuration tool and compromise other devices in the network. Affected Products: EcoStruxure™ Cybersecurity Admin Expert (CAE) (Versions prior to 2.2)"}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"HIGH","attackVector":"ADJACENT_NETWORK","availabilityImpact":"HIGH","baseScore":7.9,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-295 Improper Certificate Validation"}]}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf","name":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf"}]},"source":{"discovery":"UNKNOWN"}},"nvd":{"publishedDate":"2023-01-30 23:15:00","lastModifiedDate":"2023-04-03 17:44:00","problem_types":["CWE-295"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H","attackVector":"ADJACENT_NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":8.3,"baseSeverity":"HIGH"},"exploitabilityScore":1.6,"impactScore":6}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:ecostruxure_cybersecurity_admin_expert:*:*:*:*:*:*:*:*","versionEndExcluding":"2.4","cpe_name":[]}]}]}},"legacy_mitre":{"record":null,"notes":[]}}}