{"api_version":"1","generated_at":"2026-07-04T17:21:45+00:00","cve":"CVE-2022-35870","urls":{"html":"https://cve.report/CVE-2022-35870","api":"https://cve.report/api/cve/CVE-2022-35870.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-35870","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-35870"},"summary":{"title":"CVE-2022-35870","description":"This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition 8.1.15 (b2022030114). Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within com.inductiveautomation.metro.impl. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17265.","state":"PUBLIC","assigner":"zdi-disclosures@trendmicro.com","published_at":"2022-07-25 19:15:00","updated_at":"2022-08-03 16:53:00"},"problem_types":["CWE-502"],"metrics":[],"references":[{"url":"https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities","name":"https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities","refsource":"MISC","tags":[],"title":"Security check","mime":"text/html","httpstatus":"403","archivestatus":"404"},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-1017/","name":"https://www.zerodayinitiative.com/advisories/ZDI-22-1017/","refsource":"MISC","tags":[],"title":"ZDI-22-1017 | Zero Day Initiative","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-35870","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-35870","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2022","cve_id":"35870","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"inductiveautomation","cpe5":"ignition","cpe6":"8.1.15","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"zdi-disclosures@trendmicro.com","ID":"CVE-2022-35870","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Ignition","version":{"version_data":[{"version_value":"8.1.15 (b2022030114)"}]}}]},"vendor_name":"Inductive Automation"}]}},"credit":"@_s_n_t of @pentestltd","data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition 8.1.15 (b2022030114). Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within com.inductiveautomation.metro.impl. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17265."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-502: Deserialization of Untrusted Data"}]}]},"references":{"reference_data":[{"url":"https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities","refsource":"MISC","name":"https://support.inductiveautomation.com/hc/en-us/articles/7625759776653-Regarding-Pwn2Own-2022-Vulnerabilities"},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-1017/","refsource":"MISC","name":"https://www.zerodayinitiative.com/advisories/ZDI-22-1017/"}]},"impact":{"cvss":{"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.0"}}},"nvd":{"publishedDate":"2022-07-25 19:15:00","lastModifiedDate":"2022-08-03 16:53:00","problem_types":["CWE-502"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:inductiveautomation:ignition:8.1.15:*:*:*:*:*:*:*","cpe_name":[]}]}]}},"legacy_mitre":{"record":null,"notes":[]}}}