{"api_version":"1","generated_at":"2026-07-23T14:28:20+00:00","cve":"CVE-2022-37660","urls":{"html":"https://cve.report/CVE-2022-37660","api":"https://cve.report/api/cve/CVE-2022-37660.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-37660","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-37660"},"summary":{"title":"CVE-2022-37660","description":"In hostapd 2.10 and earlier, the PKEX code remains active even after a successful PKEX association. An attacker that successfully bootstrapped public keys with another entity using PKEX in the past, will be able to subvert a future bootstrapping by passively observing public keys, re-using the encrypting element Qi and subtracting it from the captured message M (X = M - Qi). This will result in the public ephemeral key X; the only element required to subvert the PKEX association.","state":"PUBLISHED","assigner":"mitre","published_at":"2025-02-11 23:15:08","updated_at":"2026-07-14 12:16:48"},"problem_types":["CWE-323","n/a","CWE-323 CWE-323 Reusing a Nonce, Key Pair in Encryption"],"metrics":[{"version":"3.1","source":"ADP","type":"DECLARED","score":"6.5","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N","version":"3.1"}},{"version":"3.1","source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","score":"6.5","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"}}],"references":[{"url":"https://lists.debian.org/debian-lts-announce/2025/04/msg00019.html","name":"https://lists.debian.org/debian-lts-announce/2025/04/msg00019.html","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://link.springer.com/article/10.1007/s10207-025-00988-3","name":"https://link.springer.com/article/10.1007/s10207-025-00988-3","refsource":"cve@mitre.org","tags":["Third Party Advisory"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-585531.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-585531.html","refsource":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://w1.fi/cgit/hostap/commit/?id=15af83cf1846870873a011ed4d714732f01cd2e4","name":"https://w1.fi/cgit/hostap/commit/?id=15af83cf1846870873a011ed4d714732f01cd2e4","refsource":"cve@mitre.org","tags":["Patch"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-37660","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-37660","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIDIS Secured SmartPlug","version":"affected V7.26.0310 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2022","cve_id":"37660","vulnerable":"1","versionEndIncluding":"2.10","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"w1.fi","cpe5":"hostapd","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2022","cve_id":"37660","cve":"CVE-2022-37660","epss":"0.003530000","percentile":"0.274550000","score_date":"2026-07-14","updated_at":"2026-07-15 00:14:55"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N","version":"3.1"}},{"other":{"content":{"id":"CVE-2022-37660","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2025-02-13T14:18:13.521966Z","version":"2.0.3"},"type":"ssvc"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-323","description":"CWE-323 Reusing a Nonce, Key Pair in Encryption","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2025-02-13T14:18:19.149Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"},{"providerMetadata":{"dateUpdated":"2025-11-03T19:27:21.731Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"url":"https://lists.debian.org/debian-lts-announce/2025/04/msg00019.html"}],"title":"CVE Program Container"},{"affected":[{"defaultStatus":"unknown","product":"SIDIS Secured SmartPlug","vendor":"Siemens","versions":[{"lessThan":"V7.26.0310","status":"affected","version":"0","versionType":"custom"}]}],"providerMetadata":{"dateUpdated":"2026-07-14T11:54:12.866Z","orgId":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","shortName":"siemens-SADP"},"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-585531.html"}],"x_adpType":"supplier"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"descriptions":[{"lang":"en","value":"In hostapd 2.10 and earlier, the PKEX code remains active even after a successful PKEX association. An attacker that successfully bootstrapped public keys with another entity using PKEX in the past, will be able to subvert a future bootstrapping by passively observing public keys, re-using the encrypting element Qi and subtracting it from the captured message M (X = M - Qi). This will result in the public ephemeral key X; the only element required to subvert the PKEX association."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2025-02-11T22:25:35.931Z","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre"},"references":[{"url":"https://w1.fi/cgit/hostap/commit/?id=15af83cf1846870873a011ed4d714732f01cd2e4"},{"url":"https://link.springer.com/article/10.1007/s10207-025-00988-3"}]}},"cveMetadata":{"assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","cveId":"CVE-2022-37660","datePublished":"2025-02-11T00:00:00.000Z","dateReserved":"2022-08-08T00:00:00.000Z","dateUpdated":"2026-07-14T11:54:12.866Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2025-02-11 23:15:08","lastModifiedDate":"2026-07-14 12:16:48","problem_types":["CWE-323","n/a","CWE-323 CWE-323 Reusing a Nonce, Key Pair in Encryption"],"metrics":{"cvssMetricV31":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":2.5}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2025-02-13T14:18:13.521966Z","id":"CVE-2022-37660","options":[{"exploitation":"none"},{"automatable":"yes"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:w1.fi:hostapd:*:*:*:*:*:*:*:*","versionEndIncluding":"2.10","matchCriteriaId":"9F8C7AC9-6C6F-4BCE-B72D-5D3E03D32795"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2022","CveId":"37660","Ordinal":"1","Title":"CVE-2022-37660","CVE":"CVE-2022-37660","Year":"2022"},"notes":[{"CveYear":"2022","CveId":"37660","Ordinal":"1","NoteData":"In hostapd 2.10 and earlier, the PKEX code remains active even after a successful PKEX association. An attacker that successfully bootstrapped public keys with another entity using PKEX in the past, will be able to subvert a future bootstrapping by passively observing public keys, re-using the encrypting element Qi and subtracting it from the captured message M (X = M - Qi). This will result in the public ephemeral key X; the only element required to subvert the PKEX association.","Type":"Description","Title":"CVE-2022-37660"}]}}}