{"api_version":"1","generated_at":"2026-04-23T02:38:12+00:00","cve":"CVE-2022-38758","urls":{"html":"https://cve.report/CVE-2022-38758","api":"https://cve.report/api/cve/CVE-2022-38758.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-38758","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-38758"},"summary":{"title":"CVE-2022-38758","description":"Cross-site Scripting (XSS) vulnerability in NetIQ iManager prior to version 3.2.6 allows attacker to execute malicious scripts on the user's browser. This issue affects: Micro Focus NetIQ iManager NetIQ iManager versions prior to 3.2.6 on ALL.","state":"PUBLIC","assigner":"security@microfocus.com","published_at":"2023-01-26 21:15:00","updated_at":"2023-11-07 03:50:00"},"problem_types":["CWE-79"],"metrics":[],"references":[{"url":"https://www.netiq.com/documentation/imanager-32/imanager326_releasenotes/data/imanager326_releasenotes.html","name":"https://www.netiq.com/documentation/imanager-32/imanager326_releasenotes/data/imanager326_releasenotes.html","refsource":"CONFIRM","tags":[],"title":"NetIQ iManager 3.2 Service Pack 6 Release Notes","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-38758","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-38758","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"LEGACY","value":"Special thanks to Kajetan Rostojek for responsibly disclosing this information to us.","lang":""}],"nvd_cpes":[{"cve_year":"2022","cve_id":"38758","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"netiq","cpe5":"imanager","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"security@microfocus.com","ID":"CVE-2022-38758","STATE":"PUBLIC","TITLE":"XSS vulnerabilities in iManager"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"NetIQ iManager","version":{"version_data":[{"platform":"ALL","version_affected":"<","version_name":"NetIQ iManager","version_value":"3.2.6"}]}}]},"vendor_name":"Micro Focus"}]}},"credit":[{"lang":"eng","value":"Special thanks to Kajetan Rostojek for responsibly disclosing this information to us."}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Cross-site Scripting (XSS) vulnerability in NetIQ iManager prior to version 3.2.6 allows attacker to execute malicious scripts on the user's browser. This issue affects: Micro Focus NetIQ iManager NetIQ iManager versions prior to 3.2.6 on ALL."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"HIGH","attackVector":"ADJACENT_NETWORK","availabilityImpact":"LOW","baseScore":7.2,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"CHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:L","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-79 Cross-site Scripting (XSS)"}]}]},"references":{"reference_data":[{"name":"https://www.netiq.com/documentation/imanager-32/imanager326_releasenotes/data/imanager326_releasenotes.html","refsource":"CONFIRM","url":"https://www.netiq.com/documentation/imanager-32/imanager326_releasenotes/data/imanager326_releasenotes.html"}]},"source":{"discovery":"EXTERNAL"},"work_around":[{"lang":"eng","value":"Upgrade to NetIQ iManager 3.2.6 or higher."}]},"nvd":{"publishedDate":"2023-01-26 21:15:00","lastModifiedDate":"2023-11-07 03:50:00","problem_types":["CWE-79"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE","baseScore":6.1,"baseSeverity":"MEDIUM"},"exploitabilityScore":2.8,"impactScore":2.7}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:netiq:imanager:*:*:*:*:*:*:*:*","versionEndExcluding":"3.2.6","cpe_name":[]}]}]}},"legacy_mitre":{"record":null,"notes":[]}}}