{"api_version":"1","generated_at":"2026-07-23T12:55:21+00:00","cve":"CVE-2022-41636","urls":{"html":"https://cve.report/CVE-2022-41636","api":"https://cve.report/api/cve/CVE-2022-41636.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-41636","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-41636"},"summary":{"title":"CVE-2022-41636","description":"Communication traffic involving \"Ethernet Q Commands\" service of Haas Controller version 100.20.000.1110 is transmitted in cleartext. This allows an attacker to obtain sensitive information being passed to and from the controller.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2022-10-28 18:15:00","updated_at":"2022-11-01 20:27:00"},"problem_types":["CWE-319"],"metrics":[],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-01","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-01","refsource":"MISC","tags":[],"title":"Haas Controller | CISA","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-41636","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-41636","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"LEGACY","value":"Marco Balduzzi of Trend Micro and Francesco Sortino from Celada Spa reported this vulnerability.","lang":""}],"nvd_cpes":[{"cve_year":"2022","cve_id":"41636","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"haascnc","cpe5":"haas_controller","cpe6":"100.20.000.1110","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","DATE_PUBLIC":"2022-10-25T16:28:00.000Z","ID":"CVE-2022-41636","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Haas CNC Controller","version":{"version_data":[{"version_affected":"=","version_name":"Version","version_value":"100.20.000.1110"}]}}]},"vendor_name":"Haas"}]}},"credit":[{"lang":"eng","value":"Marco Balduzzi of Trend Micro and Francesco Sortino from Celada Spa reported this vulnerability."}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Communication traffic involving \"Ethernet Q Commands\" service of Haas Controller version 100.20.000.1110 is transmitted in cleartext. This allows an attacker to obtain sensitive information being passed to and from the controller."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":9.1,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-319 Cleartext Transmission of Sensitive Information"}]}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-01","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-01"}]},"source":{"discovery":"UNKNOWN"}},"nvd":{"publishedDate":"2022-10-28 18:15:00","lastModifiedDate":"2022-11-01 20:27:00","problem_types":["CWE-319"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:haascnc:haas_controller:100.20.000.1110:*:*:*:*:*:*:*","cpe_name":[]}]}]}},"legacy_mitre":{"record":null,"notes":[]}}}