{"api_version":"1","generated_at":"2026-04-23T04:11:29+00:00","cve":"CVE-2022-43975","urls":{"html":"https://cve.report/CVE-2022-43975","api":"https://cve.report/api/cve/CVE-2022-43975.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-43975","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-43975"},"summary":{"title":"CVE-2022-43975","description":"An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p0_3.2.2.17p0_4.7p0. A vulnerability in the web server allows arbitrary files and configurations to be read via directory traversal over TCP port 8888.","state":"PUBLIC","assigner":"cve@mitre.org","published_at":"2023-01-17 21:15:00","updated_at":"2023-01-30 18:40:00"},"problem_types":["CWE-22"],"metrics":[],"references":[{"url":"https://wid.cert-bund.de/.well-known/csaf/white/2022/bsi-2022-0005.json","name":"https://wid.cert-bund.de/.well-known/csaf/white/2022/bsi-2022-0005.json","refsource":"MISC","tags":[],"title":"","mime":"application/json","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-43975","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-43975","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2022","cve_id":"43975","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"ge","cpe5":"ms_3000","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"43975","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"ge","cpe5":"ms_3000_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2022-43975","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p0_3.2.2.17p0_4.7p0. A vulnerability in the web server allows arbitrary files and configurations to be read via directory traversal over TCP port 8888."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://wid.cert-bund.de/.well-known/csaf/white/2022/bsi-2022-0005.json","url":"https://wid.cert-bund.de/.well-known/csaf/white/2022/bsi-2022-0005.json"}]}},"nvd":{"publishedDate":"2023-01-17 21:15:00","lastModifiedDate":"2023-01-30 18:40:00","problem_types":["CWE-22"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:ge:ms_3000_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"3.7.6.25p0_3.2.2.17p0_4.7p0","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:ge:ms_3000:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":null,"notes":[]}}}