{"api_version":"1","generated_at":"2026-04-23T04:22:04+00:00","cve":"CVE-2022-4608","urls":{"html":"https://cve.report/CVE-2022-4608","api":"https://cve.report/api/cve/CVE-2022-4608.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-4608","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-4608"},"summary":{"title":"CVE-2022-4608","description":"A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-3. After session resumption interval is expired an RTU500 initiated update of session parameters causes an unexpected restart due to a stack overflow.","state":"PUBLIC","assigner":"cybersecurity@hitachienergy.com","published_at":"2023-07-26 06:15:00","updated_at":"2023-08-03 14:51:00"},"problem_types":["CWE-787"],"metrics":[],"references":[{"url":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000121&LanguageCode=en&DocumentPartId=&Action=Launch","name":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000121&LanguageCode=en&DocumentPartId=&Action=Launch","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-4608","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-4608","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2022","cve_id":"4608","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hitachienergy","cpe5":"rtu500","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"4608","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachienergy","cpe5":"rtu500_firmware","cpe6":"13.3.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"4608","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachienergy","cpe5":"rtu500_firmware","cpe6":"13.3.2","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"4608","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachienergy","cpe5":"rtu500_firmware","cpe6":"13.3.3","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"4608","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachienergy","cpe5":"rtu500_firmware","cpe6":"13.4.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2022-4608","qid":"591424","title":"Hitachi Energy RTU500 series Stack-based Buffer Overflow Vulnerability (8DBD000121,ICSA-23-220-02)"}]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2022-4608","ASSIGNER":"cybersecurity@hitachienergy.com","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-3. After session resumption interval is expired an RTU500 initiated update of session parameters causes an unexpected restart due to a stack overflow."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')","cweId":"CWE-120"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Hitachi Energy","product":{"product_data":[{"product_name":"RTU500 series","version":{"version_data":[{"version_value":"not down converted","x_cve_json_5_version_data":{"versions":[{"status":"affected","version":"RTU500 series CMU Firmware version 13.3.1"},{"status":"affected","version":"RTU500 series CMU Firmware version 13.3.2"},{"status":"unaffected","version":"RTU500 series CMU Firmware version 13.3.3"},{"status":"unaffected","version":"RTU500 series CMU Firmware version 13.4.1"}],"defaultStatus":"unaffected"}}]}}]}}]}},"references":{"reference_data":[{"url":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000121&LanguageCode=en&DocumentPartId=&Action=Launch","refsource":"MISC","name":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000121&LanguageCode=en&DocumentPartId=&Action=Launch"}]},"generator":{"engine":"Vulnogram 0.1.0-dev"},"source":{"discovery":"UNKNOWN"},"configuration":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\nRTU500 series with HCI IEC 60870-5-104 and IEC 62351-3 configured and enabled.\n\n<br>"}],"value":"\nRTU500 series with HCI IEC 60870-5-104 and IEC 62351-3 configured and enabled.\n\n\n"}],"work_around":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\nDisable the HCI IEC 60870-5-104 function or its IEC 62351-3 feature if it is not used.\n\n<br>"}],"value":"\nDisable the HCI IEC 60870-5-104 function or its IEC 62351-3 feature if it is not used.\n\n\n"}],"solution":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\nUpdate to CMU Firmware versions 13.3.3 or 13.4.1.\n\n<br>"}],"value":"\nUpdate to CMU Firmware versions 13.3.3 or 13.4.1.\n\n\n"}],"impact":{"cvss":[{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"}]}},"nvd":{"publishedDate":"2023-07-26 06:15:00","lastModifiedDate":"2023-08-03 14:51:00","problem_types":["CWE-787"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:hitachienergy:rtu500_firmware:13.3.1:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:hitachienergy:rtu500_firmware:13.3.2:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:hitachienergy:rtu500_firmware:13.3.3:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:hitachienergy:rtu500_firmware:13.4.1:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:hitachienergy:rtu500:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":null,"notes":[]}}}