{"api_version":"1","generated_at":"2026-05-13T11:15:25+00:00","cve":"CVE-2022-47936","urls":{"html":"https://cve.report/CVE-2022-47936","api":"https://cve.report/api/cve/CVE-2022-47936.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2022-47936","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2022-47936"},"summary":{"title":"CVE-2022-47936","description":"A vulnerability has been identified in JT Open (All versions < V11.2.3.0), JT Utilities (All versions < V13.2.3.0), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.1 (All versions < V35.1.150). The affected application contains a stack overflow vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.","state":"PUBLIC","assigner":"productcert@siemens.com","published_at":"2023-02-14 11:15:00","updated_at":"2023-02-22 16:12:00"},"problem_types":["CWE-121"],"metrics":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2022-47936","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-47936","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2022","cve_id":"47936","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"jt_open_toolkit","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"47936","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"jt_utilities","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2022","cve_id":"47936","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"parasolid","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2022-47936","ASSIGNER":"productcert@siemens.com","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in JT Open (All versions < V11.2.3.0), JT Utilities (All versions < V13.2.3.0), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.1 (All versions < V35.1.150). The affected application contains a stack overflow vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-121: Stack-based Buffer Overflow","cweId":"CWE-121"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Siemens","product":{"product_data":[{"product_name":"JT Open","version":{"version_data":[{"version_affected":"=","version_value":"All versions < V11.2.3.0"}]}},{"product_name":"JT Utilities","version":{"version_data":[{"version_affected":"=","version_value":"All versions < V13.2.3.0"}]}},{"product_name":"Parasolid V34.0","version":{"version_data":[{"version_affected":"=","version_value":"All versions < V34.0.252"}]}},{"product_name":"Parasolid V34.1","version":{"version_data":[{"version_affected":"=","version_value":"All versions < V34.1.242"}]}},{"product_name":"Parasolid V35.0","version":{"version_data":[{"version_affected":"=","version_value":"All versions < V35.0.170"}]}},{"product_name":"Parasolid V35.1","version":{"version_data":[{"version_affected":"=","version_value":"All versions < V35.1.150"}]}}]}}]}},"references":{"reference_data":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf","refsource":"MISC","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf"}]},"impact":{"cvss":[{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","baseScore":7.8,"baseSeverity":"HIGH"}]}},"nvd":{"publishedDate":"2023-02-14 11:15:00","lastModifiedDate":"2023-02-22 16:12:00","problem_types":["CWE-121"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*","versionStartIncluding":"34.1","versionEndExcluding":"34.1.242","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*","versionStartIncluding":"34.0","versionEndExcluding":"34.0.252","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*","versionStartIncluding":"35.0","versionEndExcluding":"35.0.170","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*","versionStartIncluding":"35.1","versionEndExcluding":"35.1.150","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:jt_utilities:*:*:*:*:*:*:*:*","versionEndExcluding":"11.2.3.0","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:jt_open_toolkit:*:*:*:*:*:*:*:*","versionEndExcluding":"11.2.3.0","cpe_name":[]}]}]}},"legacy_mitre":{"record":null,"notes":[]}}}