{"api_version":"1","generated_at":"2026-04-23T09:40:17+00:00","cve":"CVE-2023-0849","urls":{"html":"https://cve.report/CVE-2023-0849","api":"https://cve.report/api/cve/CVE-2023-0849.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2023-0849","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2023-0849"},"summary":{"title":"CVE-2023-0849","description":"A vulnerability has been found in Netgear WNDR3700v2 1.0.1.14 and classified as critical. This vulnerability affects unknown code of the component Web Interface. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-221152.","state":"PUBLIC","assigner":"cna@vuldb.com","published_at":"2023-02-15 22:15:00","updated_at":"2023-11-07 04:01:00"},"problem_types":["CWE-77"],"metrics":[],"references":[{"url":"https://vuldb.com/?id.221152","name":"https://vuldb.com/?id.221152","refsource":"MISC","tags":[],"title":"Login required","mime":"text/html","httpstatus":"401","archivestatus":"404"},{"url":"https://vuldb.com/?ctiid.221152","name":"https://vuldb.com/?ctiid.221152","refsource":"MISC","tags":[],"title":"Login required","mime":"text/html","httpstatus":"401","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2023-0849","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-0849","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2023","cve_id":"849","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"netgear","cpe5":"wndr3700","cpe6":"v2","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"849","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"netgear","cpe5":"wndr3700_firmware","cpe6":"1.0.1.14","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2023-0849","ASSIGNER":"cna@vuldb.com","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"A vulnerability has been found in Netgear WNDR3700v2 1.0.1.14 and classified as critical. This vulnerability affects unknown code of the component Web Interface. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-221152."},{"lang":"deu","value":"In Netgear WNDR3700v2 1.0.1.14 wurde eine kritische Schwachstelle gefunden. Betroffen ist eine unbekannte Verarbeitung der Komponente Web Interface. Durch Manipulieren mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann über das Netzwerk passieren. Der Exploit steht zur öffentlichen Verfügung."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-77 Command Injection","cweId":"CWE-77"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Netgear","product":{"product_data":[{"product_name":"WNDR3700v2","version":{"version_data":[{"version_affected":"=","version_value":"1.0.1.14"}]}}]}}]}},"references":{"reference_data":[{"url":"https://vuldb.com/?id.221152","refsource":"MISC","name":"https://vuldb.com/?id.221152"},{"url":"https://vuldb.com/?ctiid.221152","refsource":"MISC","name":"https://vuldb.com/?ctiid.221152"}]},"credits":[{"lang":"en","value":"leetsun (VulDB User)"}],"impact":{"cvss":[{"version":"3.1","baseScore":4.7,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L","baseSeverity":"MEDIUM"},{"version":"3.0","baseScore":4.7,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L","baseSeverity":"MEDIUM"},{"version":"2.0","baseScore":5.8,"vectorString":"AV:N/AC:L/Au:M/C:P/I:P/A:P"}]}},"nvd":{"publishedDate":"2023-02-15 22:15:00","lastModifiedDate":"2023-11-07 04:01:00","problem_types":["CWE-77"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":5.9}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:netgear:wndr3700_firmware:1.0.1.14:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:netgear:wndr3700:v2:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":null,"notes":[]}}}