{"api_version":"1","generated_at":"2026-04-24T16:37:42+00:00","cve":"CVE-2023-1424","urls":{"html":"https://cve.report/CVE-2023-1424","api":"https://cve.report/api/cve/CVE-2023-1424.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2023-1424","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2023-1424"},"summary":{"title":"CVE-2023-1424","description":"Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU modules and MELSEC iQ-R Series CPU modules allows a remote unauthenticated attacker to cause a denial of service (DoS) condition or execute malicious code on a target product by sending specially crafted packets. A system reset of the product is required for recovery from a denial of service (DoS) condition and malicious code execution.","state":"PUBLIC","assigner":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","published_at":"2023-05-24 05:15:00","updated_at":"2023-07-07 04:15:00"},"problem_types":["CWE-120"],"metrics":[],"references":[{"url":"https://www.talosintelligence.com/vulnerability_reports/TALOS-2023-1727","name":"https://www.talosintelligence.com/vulnerability_reports/TALOS-2023-1727","refsource":"MISC","tags":[],"title":"TALOS-2023-1727 ||  Cisco Talos Intelligence Group - Comprehensive Threat Intelligence","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-003_en.pdf","name":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-003_en.pdf","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-143-03","name":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-143-03","refsource":"MISC","tags":[],"title":"Mitsubishi Electric MELSEC Series CPU module | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://jvn.jp/vu/JVNVU94650413","name":"https://jvn.jp/vu/JVNVU94650413","refsource":"MISC","tags":[],"title":"JVNVU#94650413: 三菱電機製MELSECシリーズのCPUユニットにおけるバッファオーバーフローの脆弱性","mime":"text/xml","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2023-1424","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-1424","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-32mr\\/ds","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-32mr\\/dss","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-32mr\\/dss_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-32mr\\/ds_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-32mr\\/es","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-32mr\\/ess","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-32mr\\/ess_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-32mr\\/es_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-32mt\\/ds","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-32mt\\/dss","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-32mt\\/dss_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-32mt\\/ds_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-32mt\\/es","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-32mt\\/ess","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-32mt\\/ess_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-32mt\\/es_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-64mr\\/ds","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-64mr\\/dss","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-64mr\\/dss_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-64mr\\/ds_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-64mr\\/es","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-64mr\\/ess","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-64mr\\/ess_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-64mr\\/es_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-64mt\\/ds","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-64mt\\/dss","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-64mt\\/dss_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-64mt\\/ds_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-64mt\\/es","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-64mt\\/ess","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-64mt\\/ess_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-64mt\\/es_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-80mr\\/ds","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-80mr\\/dss","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-80mr\\/dss_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-80mr\\/ds_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-80mr\\/es","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-80mr\\/ess","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-80mr\\/ess_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-80mr\\/es_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-80mt\\/ds","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-80mt\\/dss","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-80mt\\/dss_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-80mt\\/ds_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-80mt\\/es","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-80mt\\/ess","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-80mt\\/ess_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5u-80mt\\/es_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-32mr\\/dds","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-32mr\\/dds_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-32mr\\/ds","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-32mr\\/ds-ts","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-32mr\\/ds-ts_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-32mr\\/ds_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-32mt\\/dds","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-32mt\\/dds_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-32mt\\/ds","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-32mt\\/ds-ts","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-32mt\\/ds-ts_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-32mt\\/dss-ts","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-32mt\\/dss-ts_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-32mt\\/ds_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-64mr\\/dds","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-64mr\\/dds_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-64mr\\/ds","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-64mr\\/ds_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-64mt\\/dds","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-64mt\\/dds_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-64mt\\/ds","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-64mt\\/ds_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-96mr\\/dds","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-96mr\\/dds_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-96mr\\/ds","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-96mr\\/ds_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-96mt\\/dds","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-96mt\\/dds_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-96mt\\/ds","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1424","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"melsec_iq-fx5uc-96mt\\/ds_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2023-1424","ASSIGNER":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU modules and MELSEC iQ-R Series CPU modules allows a remote unauthenticated attacker to cause a denial of service (DoS) condition or execute malicious code on a target product by sending specially crafted packets. A system reset of the product is required for recovery from a denial of service (DoS) condition and malicious code execution."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')","cweId":"CWE-120"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Mitsubishi Electric Corporation","product":{"product_data":[{"product_name":"MELSEC iQ-F Series FX5U-32MT/ES","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5U-64MT/ES","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5U-80MT/ES","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5U-32MR/ES","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5U-64MR/ES","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5U-80MR/ES","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5U-32MT/DS","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5U-64MT/DS","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5U-80MT/DS","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5U-32MR/DS","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5U-64MR/DS","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5U-80MR/DS","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5U-32MT/ESS","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5U-64MT/ESS","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5U-80MT/ESS","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5U-32MT/DSS","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5U-64MT/DSS","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5U-80MT/DSS","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5UC-32MT/D","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5UC-64MT/D","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5UC-96MT/D","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5UC-32MT/DSS","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5UC-64MT/DSS","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5UC-96MT/DSS","version":{"version_data":[{"version_affected":"=","version_value":"Serial number 17X**** or later, versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5UC-32MT/DS-TS","version":{"version_data":[{"version_affected":"=","version_value":"versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5UC-32MT/DSS-TS","version":{"version_data":[{"version_affected":"=","version_value":"versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-F Series FX5UC-32MR/DS-TS","version":{"version_data":[{"version_affected":"=","version_value":"versions from 1.220 to 1.281"}]}},{"product_name":"MELSEC iQ-R Series R00CPU","version":{"version_data":[{"version_affected":"=","version_value":"versions 35 and prior"}]}},{"product_name":"MELSEC iQ-R Series R01CPU","version":{"version_data":[{"version_affected":"=","version_value":"versions 35 and prior"}]}},{"product_name":"MELSEC iQ-R Series R02CPU","version":{"version_data":[{"version_affected":"=","version_value":"versions 35 and prior"}]}},{"product_name":"MELSEC iQ-R Series R04CPU","version":{"version_data":[{"version_affected":"=","version_value":"versions from 12 to 68"}]}},{"product_name":"MELSEC iQ-R Series R08CPU","version":{"version_data":[{"version_affected":"=","version_value":"versions from 12 to 68"}]}},{"product_name":"MELSEC iQ-R Series R16CPU","version":{"version_data":[{"version_affected":"=","version_value":"versions from 12 to 68"}]}},{"product_name":"MELSEC iQ-R Series R32CPU","version":{"version_data":[{"version_affected":"=","version_value":"versions from 12 to 68"}]}},{"product_name":"MELSEC iQ-R Series R120CPU","version":{"version_data":[{"version_affected":"=","version_value":"versions from 12 to 68"}]}},{"product_name":"MELSEC iQ-R Series R04ENCPU","version":{"version_data":[{"version_affected":"=","version_value":"versions from 12 to 68"}]}},{"product_name":"MELSEC iQ-R Series R08ENCPU","version":{"version_data":[{"version_affected":"=","version_value":"versions from 12 to 68"}]}},{"product_name":"MELSEC iQ-R Series R16ENCPU","version":{"version_data":[{"version_affected":"=","version_value":"versions from 12 to 68"}]}},{"product_name":"MELSEC iQ-R Series R32ENCPU","version":{"version_data":[{"version_affected":"=","version_value":"versions from 12 to 68"}]}},{"product_name":"MELSEC iQ-R Series R120ENCPU","version":{"version_data":[{"version_affected":"=","version_value":"versions from 12 to 68"}]}},{"product_name":"MELSEC iQ-R Series R08SFCPU","version":{"version_data":[{"version_affected":"=","version_value":"versions 26 and later"}]}},{"product_name":"MELSEC iQ-R Series R16SFCPU","version":{"version_data":[{"version_affected":"=","version_value":"versions 26 and later"}]}},{"product_name":"MELSEC iQ-R Series R32SFCPU","version":{"version_data":[{"version_affected":"=","version_value":"versions 26 and later"}]}},{"product_name":"MELSEC iQ-R Series R120SFCPU","version":{"version_data":[{"version_affected":"=","version_value":"versions 26 and later"}]}},{"product_name":"MELSEC iQ-R Series R08PCPU","version":{"version_data":[{"version_affected":"=","version_value":"versions from 3 to 37"}]}},{"product_name":"MELSEC iQ-R Series R16PCPU","version":{"version_data":[{"version_affected":"=","version_value":"versions from 3 to 37"}]}},{"product_name":"MELSEC iQ-R Series R32PCPU","version":{"version_data":[{"version_affected":"=","version_value":"versions from 3 to 37"}]}},{"product_name":"MELSEC iQ-R Series R120PCPU","version":{"version_data":[{"version_affected":"=","version_value":"versions from 3 to 37"}]}}]}}]}},"references":{"reference_data":[{"url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-003_en.pdf","refsource":"MISC","name":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-003_en.pdf"},{"url":"https://jvn.jp/vu/JVNVU94650413","refsource":"MISC","name":"https://jvn.jp/vu/JVNVU94650413"},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-143-03","refsource":"MISC","name":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-143-03"}]},"generator":{"engine":"Vulnogram 0.1.0-dev"},"source":{"discovery":"UNKNOWN"},"impact":{"cvss":[{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":10,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","version":"3.1"}]}},"nvd":{"publishedDate":"2023-05-24 05:15:00","lastModifiedDate":"2023-07-07 04:15:00","problem_types":["CWE-120"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":8.1,"baseSeverity":"HIGH"},"exploitabilityScore":2.2,"impactScore":5.9}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-32mr\\/ds_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-32mr\\/ds:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-32mr\\/dss_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-32mr\\/dss:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-32mr\\/es_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-32mr\\/es:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-32mr\\/ess_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-32mr\\/ess:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-32mt\\/ds_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-32mt\\/ds:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-32mt\\/dss_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-32mt\\/dss:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-32mt\\/es_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-32mt\\/es:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-32mt\\/ess_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-32mt\\/ess:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-64mr\\/ds_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-64mr\\/ds:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-64mr\\/dss_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-64mr\\/dss:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-64mr\\/es_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-64mr\\/es:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-64mr\\/ess_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-64mr\\/ess:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-64mt\\/ds_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-64mt\\/ds:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-64mt\\/dss_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-64mt\\/dss:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-64mt\\/es_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-64mt\\/es:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-64mt\\/ess_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-64mt\\/ess:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-80mr\\/ds_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-80mr\\/ds:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-80mr\\/dss_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-80mr\\/dss:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-80mr\\/es_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-80mr\\/es:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-80mr\\/ess_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-80mr\\/ess:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-80mt\\/ds_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-80mt\\/ds:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-80mt\\/dss_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-80mt\\/dss:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-80mt\\/es_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-80mt\\/es:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5u-80mt\\/ess_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5u-80mt\\/ess:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-32mr\\/dds_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-32mr\\/dds:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-32mr\\/ds_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-32mr\\/ds:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-32mr\\/ds-ts_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-32mr\\/ds-ts:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-32mt\\/dds_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-32mt\\/dds:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-32mt\\/ds_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-32mt\\/ds:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-32mt\\/dss-ts_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-32mt\\/dss-ts:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-32mt\\/ds-ts_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-32mt\\/ds-ts:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-64mr\\/dds_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-64mr\\/dds:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-64mr\\/ds_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-64mr\\/ds:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-64mt\\/dds_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-64mt\\/dds:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-64mt\\/ds_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-64mt\\/ds:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-96mr\\/dds_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-96mr\\/dds:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-96mr\\/ds_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-96mr\\/ds:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-96mt\\/dds_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-96mt\\/dds:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:melsec_iq-fx5uc-96mt\\/ds_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:melsec_iq-fx5uc-96mt\\/ds:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":null,"notes":[]}}}