{"api_version":"1","generated_at":"2026-07-23T14:26:15+00:00","cve":"CVE-2023-1897","urls":{"html":"https://cve.report/CVE-2023-1897","api":"https://cve.report/api/cve/CVE-2023-1897.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2023-1897","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2023-1897"},"summary":{"title":"CVE-2023-1897","description":"Atlas Copco Power Focus 6000 web server does not sanitize the login information stored by the authenticated user’s browser, which could allow an attacker with access to the user’s computer to gain credential information of the controller.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2023-06-12 20:15:00","updated_at":"2023-11-07 04:05:00"},"problem_types":["CWE-312"],"metrics":[],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-159-01","name":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-159-01","refsource":"MISC","tags":[],"title":"Atlas Copco Power Focus 6000 | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2023-1897","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-1897","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2023","cve_id":"1897","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"atlascopco","cpe5":"power_focus_6000","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"1897","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"atlascopco","cpe5":"power_focus_6000_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2023-1897","ASSIGNER":"ics-cert@hq.dhs.gov","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"Atlas Copco Power Focus 6000 web server does not sanitize the login information stored by the authenticated user’s browser, which could allow an attacker with access to the user’s computer to gain credential information of the controller."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-312 Cleartext Storage of Sensitive Information"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Atlas Copco","product":{"product_data":[{"product_name":"Power Focus","version":{"version_data":[{"version_affected":"=","version_value":"6000"}]}}]}}]}},"references":{"reference_data":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-159-01","refsource":"MISC","name":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-159-01"}]},"generator":{"engine":"VINCE 2.1.2","env":"prod","origin":"https://cveawg.mitre.org/api/cve/CVE-2023-1897"},"source":{"discovery":"UNKNOWN"},"impact":{"cvss":[{"version":"3.1","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"LOW","availabilityImpact":"HIGH","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H","baseScore":9.4,"baseSeverity":"CRITICAL"}]}},"nvd":{"publishedDate":"2023-06-12 20:15:00","lastModifiedDate":"2023-11-07 04:05:00","problem_types":["CWE-312"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:atlascopco:power_focus_6000_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:atlascopco:power_focus_6000:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":null,"notes":[]}}}