{"api_version":"1","generated_at":"2026-06-07T07:30:15+00:00","cve":"CVE-2023-22585","urls":{"html":"https://cve.report/CVE-2023-22585","api":"https://cve.report/api/cve/CVE-2023-22585.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2023-22585","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2023-22585"},"summary":{"title":"CVE-2023-22585","description":"The Danfoss AK-EM100 web applications allow for Reflected Cross-Site Scripting in the title parameter.","state":"PUBLIC","assigner":"csirt@divd.nl","published_at":"2023-06-11 14:15:00","updated_at":"2023-06-16 03:49:00"},"problem_types":["CWE-79"],"metrics":[],"references":[{"url":"https://divd.nl/cves/CVE-2023-22585","name":"https://divd.nl/cves/CVE-2023-22585","refsource":"MISC","tags":[],"title":"DIVD /","mime":"text/html","httpstatus":"404","archivestatus":"404"},{"url":"https://csirt.divd.nl/DIVD-2023-00021","name":"https://csirt.divd.nl/DIVD-2023-00021","refsource":"MISC","tags":[],"title":"Redirecting…","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2023-22585","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-22585","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2023","cve_id":"22585","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"danfoss","cpe5":"ak-em100","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"22585","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"danfoss","cpe5":"ak-em100_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2023-22585","ASSIGNER":"csirt@divd.nl","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"The Danfoss AK-EM100 web applications allow for Reflected Cross-Site Scripting in the title parameter."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')","cweId":"CWE-79"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Danfoss","product":{"product_data":[{"product_name":"AK-EM100","version":{"version_data":[{"version_affected":"=","version_value":"< 2.2.0.12"}]}}]}}]}},"references":{"reference_data":[{"url":"https://divd.nl/cves/CVE-2023-22585","refsource":"MISC","name":"https://divd.nl/cves/CVE-2023-22585"},{"url":"https://csirt.divd.nl/DIVD-2023-00021","refsource":"MISC","name":"https://csirt.divd.nl/DIVD-2023-00021"}]},"generator":{"engine":"Vulnogram 0.1.0-dev"},"source":{"discovery":"EXTERNAL"},"work_around":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"The AK-EM100 has been declared End of Life (EOL). Danfoss advises phasing out this type of device."}],"value":"The AK-EM100 has been declared End of Life (EOL). Danfoss advises phasing out this type of device."}],"credits":[{"lang":"en","value":"Jony Schats (Hackdefense)"},{"lang":"en","value":"Stan Plasmeijer (Hackdefense)"},{"lang":"en","value":"Max van der Horst (DIVD)"}],"impact":{"cvss":[{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"CHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H","version":"3.1"}]}},"nvd":{"publishedDate":"2023-06-11 14:15:00","lastModifiedDate":"2023-06-16 03:49:00","problem_types":["CWE-79"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE","baseScore":6.1,"baseSeverity":"MEDIUM"},"exploitabilityScore":2.8,"impactScore":2.7}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:danfoss:ak-em100_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.2.0.12","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:danfoss:ak-em100:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":null,"notes":[]}}}