{"api_version":"1","generated_at":"2026-05-06T15:03:15+00:00","cve":"CVE-2023-2263","urls":{"html":"https://cve.report/CVE-2023-2263","api":"https://cve.report/api/cve/CVE-2023-2263.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2023-2263","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2023-2263"},"summary":{"title":"CVE-2023-2263","description":"The Rockwell Automation Kinetix 5700 DC Bus Power Supply Series A is vulnerable to CIP fuzzing.  The new ENIP connections cannot be established if impacted by this vulnerability,  which prohibits operational capabilities of the device resulting in a denial-of-service attack.","state":"PUBLIC","assigner":"PSIRT@rockwellautomation.com","published_at":"2023-07-18 16:15:00","updated_at":"2023-07-27 15:06:00"},"problem_types":["CWE-400"],"metrics":[],"references":[{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140029","name":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140029","refsource":"MISC","tags":[],"title":"Kinetix® 5700  DC Bus Power Supply Series A – CIP Message Attack Could Cause Denial-Of-Service","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2023-2263","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-2263","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2023","cve_id":"2263","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"rockwellautomation","cpe5":"kinetix_5700","cpe6":"series_a","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"2263","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"rockwellautomation","cpe5":"kinetix_5700_firmware","cpe6":"13.001","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2023-2263","ASSIGNER":"PSIRT@rockwellautomation.com","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"\nThe Rockwell Automation Kinetix 5700 DC Bus Power Supply Series A is vulnerable to CIP fuzzing.  The new ENIP connections cannot be established if impacted by this vulnerability,  which prohibits operational capabilities of the device resulting in a denial-of-service attack.\n\n\n"}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-400 Uncontrolled Resource Consumption","cweId":"CWE-400"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Rockwell Automation","product":{"product_data":[{"product_name":"Kinetix 5700 DC Bus Power Supply Series A ","version":{"version_data":[{"version_affected":"=","version_value":"13.001"}]}}]}}]}},"references":{"reference_data":[{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140029","refsource":"MISC","name":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140029"}]},"generator":{"engine":"Vulnogram 0.1.0-dev"},"source":{"discovery":"UNKNOWN"},"solution":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\n<ul><li>Upgrade to <a target=\"_blank\" rel=\"nofollow\" href=\"https://compatibility.rockwellautomation.com/Pages/MultiProductCompareSelections.aspx?crumb=113&amp;versions=61565\">V13.003 or later</a>&nbsp;which has been released to mitigate these issues.</li></ul>\n\n<br>"}],"value":"\n  *  Upgrade to  V13.003 or later https://compatibility.rockwellautomation.com/Pages/MultiProductCompareSelections.aspx  which has been released to mitigate these issues.\n\n\n\n\n\n"}],"impact":{"cvss":[{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"}]}},"nvd":{"publishedDate":"2023-07-18 16:15:00","lastModifiedDate":"2023-07-27 15:06:00","problem_types":["CWE-400"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:rockwellautomation:kinetix_5700_firmware:13.001:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:rockwellautomation:kinetix_5700:series_a:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":null,"notes":[]}}}