{"api_version":"1","generated_at":"2026-07-24T22:01:37+00:00","cve":"CVE-2023-2444","urls":{"html":"https://cve.report/CVE-2023-2444","api":"https://cve.report/api/cve/CVE-2023-2444.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2023-2444","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2023-2444"},"summary":{"title":"CVE-2023-2444","description":"A cross site request forgery vulnerability exists in Rockwell Automation's FactoryTalk Vantagepoint. This vulnerability can be exploited in two ways. If an attacker sends a malicious link to a computer that is on the same domain as the FactoryTalk Vantagepoint server and a user clicks the link, the attacker could impersonate the legitimate user and send requests to the affected product.  Additionally, if an attacker sends an untrusted link to a computer that is not on the same domain as the server and a user opens the FactoryTalk Vantagepoint website, enters credentials for the FactoryTalk Vantagepoint server, and clicks on the malicious link a cross site request forgery attack would be successful as well.","state":"PUBLIC","assigner":"PSIRT@rockwellautomation.com","published_at":"2023-05-11 19:15:00","updated_at":"2023-05-20 00:41:00"},"problem_types":["CWE-352"],"metrics":[],"references":[{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139443","name":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139443","refsource":"MISC","tags":[],"title":"Cross Site Request Forgery in FactoryTalk® Vantagepoint®","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2023-2444","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-2444","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2023","cve_id":"2444","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"factorytalk_vantagepoint","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2023-2444","ASSIGNER":"PSIRT@rockwellautomation.com","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"\nA cross site request forgery vulnerability exists in Rockwell Automation's FactoryTalk Vantagepoint. This vulnerability can be exploited in two ways. If an attacker sends a malicious link to a computer that is on the same domain as the FactoryTalk Vantagepoint server and a user clicks the link, the attacker could impersonate the legitimate user and send requests to the affected product.  Additionally, if an attacker sends an untrusted link to a computer that is not on the same domain as the server and a user opens the FactoryTalk Vantagepoint website, enters credentials for the FactoryTalk Vantagepoint server, and clicks on the malicious link a cross site request forgery attack would be successful as well.\n\n"}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Rockwell Automation FactoryTalk Vantagepoint Vulnerable To Cross Site Request Forgery "}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Rockwell Automation","product":{"product_data":[{"product_name":"FactoryTalk Vantagepoint","version":{"version_data":[{"version_affected":"=","version_value":"<v8.40"}]}}]}}]}},"references":{"reference_data":[{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139443","refsource":"MISC","name":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139443"}]},"generator":{"engine":"Vulnogram 0.1.0-dev"},"source":{"discovery":"UNKNOWN"},"solution":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Customers should upgrade to version 8.40 to fix the issue."}],"value":"Customers should upgrade to version 8.40 to fix the issue."}],"impact":{"cvss":[{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.1,"baseSeverity":"HIGH","confidentialityImpact":"LOW","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H","version":"3.1"}]}},"nvd":{"publishedDate":"2023-05-11 19:15:00","lastModifiedDate":"2023-05-20 00:41:00","problem_types":["CWE-352"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:rockwellautomation:factorytalk_vantagepoint:*:*:*:*:*:*:*:*","versionEndExcluding":"8.40","cpe_name":[]}]}]}},"legacy_mitre":{"record":null,"notes":[]}}}