{"api_version":"1","generated_at":"2026-07-23T12:49:15+00:00","cve":"CVE-2023-27465","urls":{"html":"https://cve.report/CVE-2023-27465","api":"https://cve.report/api/cve/CVE-2023-27465.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2023-27465","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2023-27465"},"summary":{"title":"CVE-2023-27465","description":"A vulnerability has been identified in SIMOTION C240 (All versions >= V5.4 < V5.5 SP1), SIMOTION C240 PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D410-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D410-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D425-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D425-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D435-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D435-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D445-2 DP/PN (All versions >= V5.4), SIMOTION D445-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D455-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION P320-4 E (All versions >= V5.4), SIMOTION P320-4 S (All versions >= V5.4). When operated with Security Level Low the device does not protect access to certain services relevant for debugging. This could allow an unauthenticated attacker to extract confidential technology object (TO) configuration from the device.","state":"PUBLIC","assigner":"productcert@siemens.com","published_at":"2023-06-13 09:15:00","updated_at":"2023-07-05 17:48:00"},"problem_types":["CWE-200"],"metrics":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-482956.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-482956.pdf","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2023-27465","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-27465","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2023","cve_id":"27465","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simotion_c240","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_c240_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_c240_firmware","cpe6":"5.5","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simotion_c240_pn","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_c240_pn_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_c240_pn_firmware","cpe6":"5.5","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simotion_d410-2_dp","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simotion_d410-2_dp\\/pn","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_d410-2_dp\\/pn_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_d410-2_dp\\/pn_firmware","cpe6":"5.5","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_d410-2_dp_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_d410-2_dp_firmware","cpe6":"5.5","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simotion_d425-2_dp","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simotion_d425-2_dp\\/pn","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_d425-2_dp\\/pn_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_d425-2_dp\\/pn_firmware","cpe6":"5.5","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_d425-2_dp_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_d425-2_dp_firmware","cpe6":"5.5","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simotion_d435-2_dp","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simotion_d435-2_dp\\/pn","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_d435-2_dp\\/pn_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_d435-2_dp\\/pn_firmware","cpe6":"5.5","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_d435-2_dp_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_d435-2_dp_firmware","cpe6":"5.5","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simotion_d445-2_dp\\/pn_\\(0aa0\\)","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_d445-2_dp\\/pn_\\(0aa0\\)_firmware","cpe6":"5.4","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simotion_d445-2_dp\\/pn_\\(0aa1\\)","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_d445-2_dp\\/pn_\\(0aa1\\)_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_d445-2_dp\\/pn_\\(0aa1\\)_firmware","cpe6":"5.5","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simotion_d455-2_dp\\/pn","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_d455-2_dp\\/pn_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_d455-2_dp\\/pn_firmware","cpe6":"5.5","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simotion_p320-4_e","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_p320-4_e_firmware","cpe6":"5.4","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simotion_p320-4_s","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27465","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simotion_p320-4_s_firmware","cpe6":"5.4","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2023-27465","ASSIGNER":"productcert@siemens.com","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in SIMOTION C240 (All versions >= V5.4 < V5.5 SP1), SIMOTION C240 PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D410-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D410-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D425-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D425-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D435-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D435-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D445-2 DP/PN (All versions >= V5.4), SIMOTION D445-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D455-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION P320-4 E (All versions >= V5.4), SIMOTION P320-4 S (All versions >= V5.4). When operated with Security Level Low the device does not protect access to certain services relevant for debugging. This could allow an unauthenticated attacker to extract confidential technology object (TO) configuration from the device."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-213: Exposure of Sensitive Information Due to Incompatible Policies","cweId":"CWE-213"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Siemens","product":{"product_data":[{"product_name":"SIMOTION C240","version":{"version_data":[{"version_affected":"=","version_value":"All versions >= V5.4 < V5.5 SP1"}]}},{"product_name":"SIMOTION C240 PN","version":{"version_data":[{"version_affected":"=","version_value":"All versions >= V5.4 < V5.5 SP1"}]}},{"product_name":"SIMOTION D410-2 DP","version":{"version_data":[{"version_affected":"=","version_value":"All versions >= V5.4 < V5.5 SP1"}]}},{"product_name":"SIMOTION D410-2 DP/PN","version":{"version_data":[{"version_affected":"=","version_value":"All versions >= V5.4 < V5.5 SP1"}]}},{"product_name":"SIMOTION D425-2 DP","version":{"version_data":[{"version_affected":"=","version_value":"All versions >= V5.4 < V5.5 SP1"}]}},{"product_name":"SIMOTION D425-2 DP/PN","version":{"version_data":[{"version_affected":"=","version_value":"All versions >= V5.4 < V5.5 SP1"}]}},{"product_name":"SIMOTION D435-2 DP","version":{"version_data":[{"version_affected":"=","version_value":"All versions >= V5.4 < V5.5 SP1"}]}},{"product_name":"SIMOTION D435-2 DP/PN","version":{"version_data":[{"version_affected":"=","version_value":"All versions >= V5.4 < V5.5 SP1"}]}},{"product_name":"SIMOTION D445-2 DP/PN","version":{"version_data":[{"version_affected":"=","version_value":"All versions >= V5.4"},{"version_affected":"=","version_value":"All versions >= V5.4 < V5.5 SP1"}]}},{"product_name":"SIMOTION D455-2 DP/PN","version":{"version_data":[{"version_affected":"=","version_value":"All versions >= V5.4 < V5.5 SP1"}]}},{"product_name":"SIMOTION P320-4 E","version":{"version_data":[{"version_affected":"=","version_value":"All versions >= V5.4"}]}},{"product_name":"SIMOTION P320-4 S","version":{"version_data":[{"version_affected":"=","version_value":"All versions >= V5.4"}]}}]}}]}},"references":{"reference_data":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-482956.pdf","refsource":"MISC","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-482956.pdf"}]},"impact":{"cvss":[{"version":"3.1","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C","baseScore":4.6,"baseSeverity":"MEDIUM"}]}},"nvd":{"publishedDate":"2023-06-13 09:15:00","lastModifiedDate":"2023-07-05 17:48:00","problem_types":["CWE-200"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","attackVector":"PHYSICAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":4.6,"baseSeverity":"MEDIUM"},"exploitabilityScore":0.9,"impactScore":3.6}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_d425-2_dp_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"5.4","versionEndExcluding":"5.5","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_d425-2_dp_firmware:5.5:-:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simotion_d425-2_dp:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_d425-2_dp\\/pn_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"5.4","versionEndExcluding":"5.5","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_d425-2_dp\\/pn_firmware:5.5:-:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simotion_d425-2_dp\\/pn:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_d435-2_dp_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"5.4","versionEndExcluding":"5.5","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_d435-2_dp_firmware:5.5:-:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simotion_d435-2_dp:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_d435-2_dp\\/pn_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"5.4","versionEndExcluding":"5.5","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_d435-2_dp\\/pn_firmware:5.5:-:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simotion_d435-2_dp\\/pn:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_d445-2_dp\\/pn_\\(0aa1\\)_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"5.4","versionEndExcluding":"5.5","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_d445-2_dp\\/pn_\\(0aa1\\)_firmware:5.5:-:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simotion_d445-2_dp\\/pn_\\(0aa1\\):-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_d445-2_dp\\/pn_\\(0aa0\\)_firmware:5.4:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simotion_d445-2_dp\\/pn_\\(0aa0\\):-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_d455-2_dp\\/pn_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"5.4","versionEndExcluding":"5.5","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_d455-2_dp\\/pn_firmware:5.5:-:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simotion_d455-2_dp\\/pn:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_p320-4_e_firmware:5.4:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simotion_p320-4_e:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_p320-4_s_firmware:5.4:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simotion_p320-4_s:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_d410-2_dp_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"5.4","versionEndExcluding":"5.5","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_d410-2_dp_firmware:5.5:-:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simotion_d410-2_dp:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_d410-2_dp\\/pn_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"5.4","versionEndExcluding":"5.5","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_d410-2_dp\\/pn_firmware:5.5:-:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simotion_d410-2_dp\\/pn:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_c240_pn_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"5.4","versionEndExcluding":"5.5","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_c240_pn_firmware:5.5:-:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simotion_c240_pn:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_c240_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"5.4","versionEndExcluding":"5.5","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simotion_c240_firmware:5.5:-:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simotion_c240:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":null,"notes":[]}}}