{"api_version":"1","generated_at":"2026-07-23T13:22:44+00:00","cve":"CVE-2023-2758","urls":{"html":"https://cve.report/CVE-2023-2758","api":"https://cve.report/api/cve/CVE-2023-2758.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2023-2758","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2023-2758"},"summary":{"title":"CVE-2023-2758","description":"A denial of service vulnerability exists in Contec CONPROSYS HMI System versions 3.5.2 and prior. When there is a time-zone mismatch in certain configuration files, a remote, unauthenticated attacker may deny logins for an extended period of time.","state":"PUBLIC","assigner":"vulnreport@tenable.com","published_at":"2023-05-31 15:15:00","updated_at":"2023-06-07 14:35:00"},"problem_types":["NVD-CWE-Other"],"metrics":[],"references":[{"url":"https://www.tenable.com/security/research/tra-2023-21","name":"https://www.tenable.com/security/research/tra-2023-21","refsource":"MISC","tags":[],"title":"Contec CONPROSYS HMI System Login DoS - Research Advisory | Tenable®","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://jvn.jp/en/vu/JVNVU93372935/index.html","name":"https://jvn.jp/en/vu/JVNVU93372935/index.html","refsource":"MISC","tags":[],"title":"JVNVU#93372935: Multiple vulnerabilities in Contec CONPROSYS HMI System (CHS)","mime":"text/xml","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2023-2758","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-2758","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2023","cve_id":"2758","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"contec","cpe5":"conprosys_hmi_system","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2023-2758","ASSIGNER":"vulnreport@tenable.com","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"A denial of service vulnerability exists in Contec CONPROSYS HMI System versions 3.5.2 and prior. When there is a time-zone mismatch in certain configuration files, a remote, unauthenticated attacker may deny logins for an extended period of time."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-799","cweId":"CWE-799"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Contec","product":{"product_data":[{"product_name":"CONPROSYS HMI System","version":{"version_data":[{"version_affected":"<=","version_name":"0","version_value":"3.5.2"}]}}]}}]}},"references":{"reference_data":[{"url":"https://www.tenable.com/security/research/tra-2023-21","refsource":"MISC","name":"https://www.tenable.com/security/research/tra-2023-21"},{"url":"https://jvn.jp/en/vu/JVNVU93372935/index.html","refsource":"MISC","name":"https://jvn.jp/en/vu/JVNVU93372935/index.html"}]},"generator":{"engine":"Vulnogram 0.1.0-dev"},"source":{"discovery":"UNKNOWN"},"impact":{"cvss":[{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":3.7,"baseSeverity":"LOW","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L","version":"3.1"}]}},"nvd":{"publishedDate":"2023-05-31 15:15:00","lastModifiedDate":"2023-06-07 14:35:00","problem_types":["NVD-CWE-Other"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"LOW","baseScore":5.3,"baseSeverity":"MEDIUM"},"exploitabilityScore":3.9,"impactScore":1.4}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*","versionEndExcluding":"3.5.3","cpe_name":[]}]}]}},"legacy_mitre":{"record":null,"notes":[]}}}