{"api_version":"1","generated_at":"2026-04-22T23:09:05+00:00","cve":"CVE-2023-27980","urls":{"html":"https://cve.report/CVE-2023-27980","api":"https://cve.report/api/cve/CVE-2023-27980.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2023-27980","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2023-27980"},"summary":{"title":"CVE-2023-27980","description":"A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow the creation of a malicious report file in the IGSS project report directory, this could lead to remote code execution when a victim eventually opens the report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2023-03-21 06:15:00","updated_at":"2023-03-24 19:15:00"},"problem_types":["CWE-306"],"metrics":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-04.pdf","name":"N/A","refsource":"CONFIRM","tags":[],"title":"","mime":"application/pdf","httpstatus":"-1","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2023-27980","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-27980","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2023","cve_id":"27980","vulnerable":"1","versionEndIncluding":"16.0.0.23040","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"custom_reports","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27980","vulnerable":"1","versionEndIncluding":"16.0.0.23040","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"igss_dashboard","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"27980","vulnerable":"1","versionEndIncluding":"16.0.0.23040","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"igss_data_server","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","ID":"CVE-2023-27980","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"IGSS Data Server(IGSSdataServer.exe)","version":{"version_data":[{"version_affected":"<=","version_name":"V","version_value":"16.0.0.23040"}]}},{"product_name":"IGSS Dashboard (DashBoard.exe)","version":{"version_data":[{"version_affected":"<=","version_name":"V","version_value":"16.0.0.23040"}]}},{"product_name":"Custom Reports (RMS16.dll)","version":{"version_data":[{"version_affected":"<=","version_name":"V","version_value":"16.0.0.23040"}]}}]},"vendor_name":"Schneider Electric"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow the creation of a malicious report file in the IGSS project report directory, this could lead to remote code execution when a victim eventually opens the report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)"}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-306 Missing Authentication for Critical Function"}]}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-04.pdf","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-04.pdf"}]},"source":{"discovery":"UNKNOWN"}},"nvd":{"publishedDate":"2023-03-21 06:15:00","lastModifiedDate":"2023-03-24 19:15:00","problem_types":["CWE-306"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:custom_reports:*:*:*:*:*:*:*:*","versionEndIncluding":"16.0.0.23040","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:igss_dashboard:*:*:*:*:*:*:*:*","versionEndIncluding":"16.0.0.23040","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:igss_data_server:*:*:*:*:*:*:*:*","versionEndIncluding":"16.0.0.23040","cpe_name":[]}]}]}},"legacy_mitre":{"record":null,"notes":[]}}}