{"api_version":"1","generated_at":"2026-07-23T12:19:34+00:00","cve":"CVE-2023-28398","urls":{"html":"https://cve.report/CVE-2023-28398","api":"https://cve.report/api/cve/CVE-2023-28398.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2023-28398","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2023-28398"},"summary":{"title":"CVE-2023-28398","description":"Osprey Pump Controller version 1.01 could allow an unauthenticated user to create an account and bypass authentication, thereby gaining unauthorized access to the system. A threat actor could exploit this vulnerability to create a user account without providing valid credentials. A threat actor who successfully exploits this vulnerability could gain access to the pump controller and cause disruption in operation, modify data, or shut down the controller.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2023-03-28 21:15:00","updated_at":"2023-11-07 04:10:00"},"problem_types":["CWE-287"],"metrics":[],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06","name":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06","refsource":"MISC","tags":[],"title":"ProPump and Controls Osprey Pump Controller | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2023-28398","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-28398","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2023","cve_id":"28398","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"propumpservice","cpe5":"osprey_pump_controller","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"28398","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"propumpservice","cpe5":"osprey_pump_controller_firmware","cpe6":"1.01","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2023-28398","ASSIGNER":"ics-cert@hq.dhs.gov","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"Osprey Pump Controller version 1.01 could allow an unauthenticated user to create an account and bypass authentication, thereby gaining unauthorized access to the system. A threat actor could exploit this vulnerability to create a user account without providing valid credentials. A threat actor who successfully exploits this vulnerability could gain access to the pump controller and cause disruption in operation, modify data, or shut down the controller."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-288 Authentication Bypass Using an Alternate Path or Channel"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"ProPump and Controls, Inc.","product":{"product_data":[{"product_name":"Osprey Pump Controller","version":{"version_data":[{"version_affected":"=","version_value":"1.01"}]}}]}}]}},"references":{"reference_data":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06","refsource":"MISC","name":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"}]},"generator":{"engine":"VINCE 2.0.7","env":"prod","origin":"https://cveawg.mitre.org/api/cve/CVE-2023-28398"},"source":{"discovery":"UNKNOWN"},"impact":{"cvss":[{"version":"3.1","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL"}]}},"nvd":{"publishedDate":"2023-03-28 21:15:00","lastModifiedDate":"2023-11-07 04:10:00","problem_types":["CWE-287"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":5.9}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:propumpservice:osprey_pump_controller_firmware:1.01:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:propumpservice:osprey_pump_controller:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":null,"notes":[]}}}