{"api_version":"1","generated_at":"2026-04-23T04:11:08+00:00","cve":"CVE-2023-29241","urls":{"html":"https://cve.report/CVE-2023-29241","api":"https://cve.report/api/cve/CVE-2023-29241.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2023-29241","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2023-29241"},"summary":{"title":"CVE-2023-29241","description":"Improper Information in Cybersecurity Guidebook in Bosch Building Integration System (BIS) 5.0 may lead to wrong configuration which allows local users to access data via network","state":"PUBLIC","assigner":"psirt@bosch.com","published_at":"2023-06-30 22:15:00","updated_at":"2023-07-12 13:37:00"},"problem_types":["NVD-CWE-Other"],"metrics":[],"references":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-988400-BT.html","name":"https://psirt.bosch.com/security-advisories/BOSCH-SA-988400-BT.html","refsource":"MISC","tags":[],"title":"Update in Cybersecurity Guidebook of BIS on Permission Settings for Network Share | Bosch PSIRT","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2023-29241","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-29241","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2023","cve_id":"29241","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"bosch","cpe5":"building_integration_system","cpe6":"5.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2023-29241","ASSIGNER":"psirt@bosch.com","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Bosch","product":{"product_data":[{"product_name":"BIS","version":{"version_data":[{"version_value":"5.0","version_affected":"="}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-1112 Incomplete Documentation of Program Execution"}]}]},"impact":{"cvss":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE","baseScore":8.1,"baseSeverity":"HIGH"}},"references":{"reference_data":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-988400-BT.html","name":"https://psirt.bosch.com/security-advisories/BOSCH-SA-988400-BT.html","refsource":"MISC"}]},"description":{"description_data":[{"lang":"eng","value":"Improper Information in Cybersecurity Guidebook in Bosch Building Integration System (BIS) 5.0 may lead to wrong configuration which allows local users to access data via network"}]},"source":{"discovery":"INTERNAL"}},"nvd":{"publishedDate":"2023-06-30 22:15:00","lastModifiedDate":"2023-07-12 13:37:00","problem_types":["NVD-CWE-Other"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE","baseScore":7.1,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.2}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:bosch:building_integration_system:5.0:*:*:*:*:*:*:*","cpe_name":[]}]}]}},"legacy_mitre":{"record":null,"notes":[]}}}