{"api_version":"1","generated_at":"2026-07-23T15:43:20+00:00","cve":"CVE-2023-33919","urls":{"html":"https://cve.report/CVE-2023-33919","api":"https://cve.report/api/cve/CVE-2023-33919.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2023-33919","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2023-33919"},"summary":{"title":"CVE-2023-33919","description":"A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.","state":"PUBLIC","assigner":"productcert@siemens.com","published_at":"2023-06-13 09:15:00","updated_at":"2023-07-11 18:15:00"},"problem_types":["CWE-77"],"metrics":[],"references":[{"url":"http://packetstormsecurity.com/files/173370/Siemens-A8000-CP-8050-CP-8031-Code-Execution-Command-Injection.html","name":"http://packetstormsecurity.com/files/173370/Siemens-A8000-CP-8050-CP-8031-Code-Execution-Command-Injection.html","refsource":"MISC","tags":[],"title":"Siemens A8000 CP-8050 / CP-8031 Code Execution / Command Injection ≈ Packet Storm","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"http://seclists.org/fulldisclosure/2023/Jul/14","name":"http://seclists.org/fulldisclosure/2023/Jul/14","refsource":"MISC","tags":[],"title":"Full Disclosure: SEC Consult SA-20230703-0 :: Multiple Vulnerabilities including Unauthenticated RCE in Siemens A8000","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-731916.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-731916.pdf","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2023-33919","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-33919","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2023","cve_id":"33919","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"cp-8031_master_module","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"33919","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"cp-8050_master_module","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"33919","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"cpci85_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2023-33919","ASSIGNER":"productcert@siemens.com","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection')","cweId":"CWE-77"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Siemens","product":{"product_data":[{"product_name":"CP-8031 MASTER MODULE","version":{"version_data":[{"version_affected":"=","version_value":"All versions < CPCI85 V05"}]}},{"product_name":"CP-8050 MASTER MODULE","version":{"version_data":[{"version_affected":"=","version_value":"All versions < CPCI85 V05"}]}}]}}]}},"references":{"reference_data":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-731916.pdf","refsource":"MISC","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-731916.pdf"},{"url":"http://seclists.org/fulldisclosure/2023/Jul/14","refsource":"MISC","name":"http://seclists.org/fulldisclosure/2023/Jul/14"},{"url":"http://packetstormsecurity.com/files/173370/Siemens-A8000-CP-8050-CP-8031-Code-Execution-Command-Injection.html","refsource":"MISC","name":"http://packetstormsecurity.com/files/173370/Siemens-A8000-CP-8050-CP-8031-Code-Execution-Command-Injection.html"}]},"impact":{"cvss":[{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","baseScore":7.2,"baseSeverity":"HIGH"}]}},"nvd":{"publishedDate":"2023-06-13 09:15:00","lastModifiedDate":"2023-07-11 18:15:00","problem_types":["CWE-77"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.2,"baseSeverity":"HIGH"},"exploitabilityScore":1.2,"impactScore":5.9}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:cpci85_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"v05","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:cp-8031_master_module:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:cpci85_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"v05","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:cp-8050_master_module:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":null,"notes":[]}}}