{"api_version":"1","generated_at":"2026-04-23T00:42:07+00:00","cve":"CVE-2023-35796","urls":{"html":"https://cve.report/CVE-2023-35796","api":"https://cve.report/api/cve/CVE-2023-35796.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2023-35796","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2023-35796"},"summary":{"title":"CVE-2023-35796","description":"A vulnerability has been identified in SINEMA Server V14 (All versions). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could perform a stored cross-site scripting (XSS) attack that may lead to arbitrary code execution with `SYSTEM` privileges on the application server. (ZDI-CAN-19823)","state":"PUBLIC","assigner":"productcert@siemens.com","published_at":"2023-10-10 11:15:00","updated_at":"2023-10-24 12:25:00"},"problem_types":["CWE-79"],"metrics":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-594373.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-594373.pdf","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2023-35796","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-35796","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2023","cve_id":"35796","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"sinema_server","cpe6":"14.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2023-35796","ASSIGNER":"productcert@siemens.com","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in SINEMA Server V14 (All versions). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could perform a stored cross-site scripting (XSS) attack that may lead to arbitrary code execution with `SYSTEM` privileges on the application server. (ZDI-CAN-19823)"}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')","cweId":"CWE-79"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Siemens","product":{"product_data":[{"product_name":"SINEMA Server V14","version":{"version_data":[{"version_affected":"=","version_value":"All versions"}]}}]}}]}},"references":{"reference_data":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-594373.pdf","refsource":"MISC","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-594373.pdf"}]},"impact":{"cvss":[{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H/E:P/RL:U/RC:C","baseScore":8.3,"baseSeverity":"HIGH"}]}},"nvd":{"publishedDate":"2023-10-10 11:15:00","lastModifiedDate":"2023-10-24 12:25:00","problem_types":["CWE-79"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":9,"baseSeverity":"CRITICAL"},"exploitabilityScore":2.3,"impactScore":6}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:sinema_server:14.0:*:*:*:*:*:*:*","cpe_name":[]}]}]}},"legacy_mitre":{"record":null,"notes":[]}}}